Table of Contents

On November 23, 2026, ABB announced that it had signed an agreement to acquire German fan manufacturer Ziehl-Abegg at an enterprise value of $2.65 billion. ABB expects the deal to close in the second half of 2027, subject to regulatory approvals and customary closing conditions. The proposed acquisition would add electronically commutated (EC) fans and integrated motors to ABB Motion’s portfolio for HVAC, industrial cooling and thermal management. ABB announcement · Ziehl-Abegg announcement

What should HVAC buyers check on current projects?

For an active project, confirm open orders, delivery milestones, warranty contacts and availability of critical spares with your current supplier. Record the approved fan part number, drawing revision and controller settings in the project file. The announcements describe the agreement and expected timing. Obtain current supply and service terms directly for each project.

Replacement and new-equipment sourcing have different timelines. For equipment already in service, identify which failures could stop operation and arrange any necessary spares around the maintenance schedule. For new equipment or repeat production, put second-source sample testing on the engineering schedule before the next purchasing decision. Once the sample passes, record the approved configuration and the conditions under which it can be used.

How to evaluate a Ziehl-Abegg fan replacement

  1. Identify the full part number. Capture the nameplate, every suffix and the drawing revision. Record the application and original fan arrangement.
  2. Compare at the installed duty point. Specify required airflow and static pressure together. Compare input power and noise under comparable conditions and check the operating range.
  3. Check the installation. Verify mounting holes, inlet ring, overall depth, rotation, airflow direction and clearance against dimensioned drawings.
  4. Verify power and controls. Check voltage and phase, speed command, feedback and fail-safe behavior. For Modbus, review the wiring and register map for the exact controller. Include required approvals and environmental conditions.

Use these inputs to agree on sample acceptance criteria before testing. Where the equipment has several operating modes, include the loads and control states that matter in service. Fan replacement checklist

What a second-source sample evaluation looks like

In a precision air-conditioning project in India, the equipment maker evaluated 560 mm EC backward-curved fan candidates for units using Ziehl-Abegg and Rosenberg fans. LONGWELL supplied two configurations for evaluation. The review used the incumbent datasheet, pressure–flow curve and installation arrangement, and the customer required physical testing for qualification. The project notes record the sample stage. Precision cooling project evidence

For an air-handling unit, the filters and coils also shape the system pressure, so validate the candidate against the actual unit. A condenser fan review has its own constraints, including coil resistance, depth and controller input. AHU fan engineering examples · Industrial condenser fan case

Ask LONGWELL to review a replacement candidate

LONGWELL can review EC fan candidates for many mainstream replacement applications. Start with the fan cross-reference guide, or request an engineering review with the original part number or nameplate, required airflow and static pressure, and a drawing if available. Final selection is confirmed against the full model, installation, controls and project tests. LONGWELL is an independent manufacturer. Brand names identify the equipment under review.

Get A Quote

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Recent Articles

Categories

Archives