Project Qualification Pack · V1.0 · 2026-05

Commercial HVAC
End-to-End Fan & Motor Qualification Pack

A code-compliant fan platform for AHU / RTU / FCU / evaporator-condenser applications under DOE 2023 · ErP Tier 2 · IECC 2024 — LWBE3G backward-curved for AHU/RTU, LWFC forward-curved for FCU, LWAA axial for evaporators and condensers, LWM EC motor as the common drive. One supplier, four series, Fortune 500 validated.

2.6M+
Commercial fans / year
LWBE3G + LWFC + LWAA cumulative
70-72%
Fan system efficiency
DOE 2023 requires ≥ 67%
6.5 dB(A)
Noise reduction
vs customer incumbent baseline
90 Days
Spec to mass production
vs industry 12-24 months
Why LONGWELL for Commercial HVAC

Why Commercial HVAC Projects Choose LONGWELL

Commercial HVAC engineering pressure tightens on four fronts at once: energy codes (ASHRAE 90.1-2022 / EU ErP Lot 6 / DOE 2023 / IECC 2024), quiet-operation requirements for offices and healthcare, hard BMS-integration requirements from BIM/MEP engineering teams, and a 10-15 year service-life expectation. The LWBE3G + LWFC + LWAA + LWM platform treats all four as engineering preconditions from day one, not as later retrofits.

Complete HVAC Portfolio

Complete Commercial HVAC Portfolio

LWBE3G backward-curved (AHU/RTU) + LWFC forward-curved (FCU/terminal) + LWAA axial (evaporator-condenser) + LWM EC motor common platform. A single supplier covering 95% of commercial HVAC OEM fan needs.

Code Compliance Built-In

Energy Codes Cleared in One Pass

EC motor efficiency 88-92% — meets IE4 / EU ErP Tier 2 / DOE 2023 (67% fan system efficiency) / IECC 2024 out of the box. Field-measured 70-72% at a Top-3 North American RTU OEM.

Quiet Operation for Occupied Spaces

Quiet for Offices & Healthcare

FCU conditions as low as 28-35 dB(A); AHU/RTU conditions typically 38-48 dB(A). Biomimetic blade profile + proprietary EC control algorithms cut up to 6.5 dB(A) versus the AC baseline.

BMS / BAS Integration

Native Building Automation Integration

Modbus RTU + BACnet MS-TP standard, CANopen optional. Interoperability verified with Schneider EcoStruxure / JCI Metasys / Honeywell / Siemens Desigo BMS.

90-Day NPI + Stable Supply

90-Day NPI + Production Stability

A Top-3 North American RTU OEM moved from 2023 inquiry to mass-production release across 6 sizes in just 90 days. 30 months of stable supply with zero field quality incidents. 3-year frame agreement renewed in 2026.

A Letter from the Founder

To Our Commercial HVAC Project Partners

What's Inside (28 pages / 5 sections)

  • §1 Company & Manufacturing
  • §2 Product Portfolio Overview
  • §2.5 ★ Commercial HVAC Module
  • §3 Quality & Compliance
  • §3.5 ★ Project Evidence Layer
  • §4 Engagement & Next Step

Fastest Path · Model-fit only — jump to §3.5 Application Configuration Matrix. Sign NDA and kick off — jump to §4 Engagement Paths.

To commercial HVAC OEMs, BIM/MEP engineering leads, and ESCO partners:

Thank you for advancing LONGWELL through your supplier qualification process. This Project Qualification Pack is tailored to your commercial HVAC application — extending the initial Supplier Qualification Pack with industry-specific technical detail, the series we recommend for your application, anonymized case evidence from comparable customers, and the test reports you will need at RFQ and DV/PV stages.

Every page beyond §2.5 has been selected because it is directly relevant to your commercial HVAC product line. The series pages reflect what we actually recommend for AHU, RTU, FCU and evaporator applications. The application matrix on the inside back cover maps your product taxonomy to ours, so your engineering team can validate fit at a glance.

Inside the next 28 pages you will find: our company foundation, our complete product portfolio, the four commercial-HVAC-relevant series with full specifications, our quality and compliance evidence, anonymized customer reference data, our checked test report inventory, and a clear engagement next-step path including indicative timelines and commercial terms. When you are ready to discuss specific models or request samples — my team can be on a call with your engineering and procurement leads within 48 hours.

Bruce Li Founder & CEO, LONGWELL · bruce@zjlongwell.com
§2.5 · Commercial HVAC Market Context

Commercial HVAC Market Context

The global commercial HVAC market exceeds USD 200B annually and is growing at 6-8% CAGR through 2030. Three forces are converging at once: spill-over demand from data center cooling, post-pandemic indoor air quality regulations, and the tightening of energy codes (ASHRAE 90.1-2022, EU ErP Lot 6, IECC 2024). These are not incremental adjustments — they are an engineering-precondition reset for every commercial HVAC OEM.

OEM Pain PointImpact on OEMLONGWELL Response
Tightening efficiency rules
Code compliance
DOE 2023 / ErP Tier 2 / IECC mandate IE4 + fan system efficiency ≥ 67%LWM EC platform 88-92% efficiency · field-measured 70-72%
Quiet-operation demand
Office, healthcare, education
Office / healthcare / education ≤ 45 dB(A) @ 1m; FCU applications even ≤ 35 dB(A)LWFC at FCU condition 28-35 dB(A) · LWAA tip speed 30% below baseline
BMS / BAS integration
Building automation
Modbus RTU / BACnet MS-TP standard with smart speed control and remote diagnosticsFull EC platform native Modbus + BACnet; verified with Schneider / JCI / Honeywell
10-15 year service life
Long-life duty cycle
L10 bearing life ≥ 60,000h @ 40°C; DV/PV requires accelerated aging dataL10 ≥ 60,000h @ 40°C · ≥ 40,000h @ 60°C · accelerated aging data available
Key Engineering Conclusion
For any commercial HVAC platform whose design kicks off after 2024, the EC motor is no longer "optional" — it is a "compliance precondition." AC-based platforms can no longer be certified against the new codes. LONGWELL serves multiple Top-5 North American RTU/AHU OEMs, three leading European FCU brands, and Asian commercial-building MEP integrators.
Global Energy Code Landscape

Global Energy Codes for Commercial HVAC

Fan System Efficiency (FEI) and motor energy class (IE4) are the two anchor metrics across every current commercial HVAC energy code. The LONGWELL EC platform is engineered around both from the start.

Regional Energy Codes & Targets

Region / RegulationCore RequirementEffective
USA DOE 2023Fan system efficiency ≥ 67% · applies to commercial RTU / AHUMandatory from 2023-01-01
USA ASHRAE 90.1-2022FEI (Fan Energy Index) ≥ 1.00 · fan power limitsProgressively adopted by states from 2024
USA IECC 2024FEI ≥ 1.00 + IE4 motor mandate for fansState-by-state adoption 2024-2025
EU ErP Tier 2 (Lot 6)Fan Minimum Efficiency Index FMEI ≥ 0.50-0.62 · tiered by airflowMandatory from 2015, revised 2022
EU ErP Lot 11 (Motors)IE4 motor mandate (0.12-1000 kW range)Phased rollout from 2023-07
China GB 21455VRF energy efficiency APF ≥ 4.5 · Grade 12020 revision in force

Application Noise Targets vs LONGWELL Measured

ApplicationTypical Site Noise TargetLONGWELL MeasuredSeries
Office AHU≤ 45 dB(A) @ 1m38-45 dB(A)LWBE3G EC
Healthcare / Education FCU≤ 35 dB(A) @ 1m28-35 dB(A)LWFC EC
Rooftop RTU (outdoor)≤ 65 dB(A) @ 1m48-58 dB(A)LWBE3G EC
Evaporator / Condenser≤ 60 dB(A) @ 1m32-58 dB(A)LWAA EC (tip speed -30%)

LONGWELL supplies EC fan platforms to multiple North American RTU/AHU OEMs and European FCU brands. All EC variants meet DOE 2023 / ErP Tier 2 / IECC 2024 while hitting application-level noise targets simultaneously.

§2 · Four Application Layers

Four-Layer Commercial HVAC Fan Architecture

Modern commercial HVAC is not a single equipment type — it is four fan-application classes operating side by side. Each class has its own aerodynamic, static-pressure, noise and form-factor requirements. LONGWELL engineered products cover all four layers, and every EC variant runs on the common LWM motor platform.

L1

AHU / Air Handling Unit
Air Handling Unit

LWBE3G backward-curved EC, 3G biomimetic blade profile, 88-92% efficiency.

5,000-32,000 m³/h · 400-1,500 Pa · +5-8 pp static efficiency
L2

RTU / Rooftop Unit
Rooftop Unit

LWBE3G backward-curved EC with IP55 outdoor configuration + mandatory UL/ETL for North America.

3,000-20,000 m³/h · 300-800 Pa · DOE 2023 compliant
L3

FCU / Fan Coil Unit
Fan Coil Unit · Terminal

LWFC forward-curved EC with 2024-redesigned scroll geometry.

200-2,000 m³/h · 30-200 Pa · 28-35 dB(A) FCU-grade quiet
L4

Evaporator / Condenser
Evaporator / Condenser

LWAA axial EC with aluminum-alloy + composite hybrid blades.

1,500-15,000 m³/h · 80-400 Pa · tip speed -30%
LONGWELL Coverage: this Pack covers AHU / RTU / FCU / evaporator-condenser — the 95% scope of interest to most commercial HVAC OEMs. Specialty cases (LWDF duct booster, LWCB commercial blower) are available on separate request.
§3 · Product Mapping

Product Selection · LWBE3G + LWFC + LWAA + LWM

Exact selection parameters across the four series, matched to commercial HVAC application, energy code and noise targets. Every EC variant runs on the common LWM motor platform.

L1 / L2 · AHU & RTU Selection — LWBE3G Backward-Curved

3G-generation biomimetic blade profile delivers 5-8 percentage points of static efficiency over conventional backward-curved designs. 12 sizes cover 190-710 mm; EC variants meet DOE 2023 / ErP Tier 2 / IE4.

AHU/RTU CapacityRecommended SizeAirflowStatic PressureEC Efficiency
5,000 m³/h (small AHU / 3-5 ton RTU)LWBE3G-3553,500-7,000 m³/h400-800 Pa88%
10,000 m³/h (medium AHU / 7-10 ton RTU)LWBE3G-4507,500-13,000 m³/h500-1,000 Pa90%
18,000 m³/h (large AHU / 15-20 ton RTU)LWBE3G-56014,000-22,000 m³/h600-1,200 Pa91%
30,000 m³/h (XL AHU / 25 ton RTU)LWBE3G-71022,000-30,000 m³/h800-1,800 Pa92%
▸ Verified BMS / BAS Compatibility (Schneider · JCI · Honeywell · Siemens · Trane)
Schneider EcoStruxure✓ VerifiedModbus RTU + BACnet MS-TP dual protocol
Johnson Controls Metasys✓ VerifiedBACnet MS-TP compatible
Honeywell Enterprise BMS✓ VerifiedModbus RTU compatible
Siemens Desigo CC✓ VerifiedBACnet/IP gateway compatible
Trane Tracer SC+✓ VerifiedIntegrated by a North American RTU OEM

L3 · FCU Selection — LWFC Forward-Curved

2024-redesigned scroll geometry lifts total efficiency at the operating point to 65-72% (vs typical industry 55-60%). FCU conditions reach 28-35 dB(A) — fit for healthcare, education and premium office.

FCU CapacityRecommended SizeAirflowStatic PressureNoise @ Operating Point
2-rowLWFC-146 DI200-500 m³/h30-80 Pa28-32 dB(A)
3-rowLWFC-180 DI400-800 m³/h50-120 Pa30-35 dB(A)
4-rowLWFC-225 DI700-1,400 m³/h80-180 Pa33-40 dB(A)
Large FCU / Small AHULWFC-280 DI1,200-2,000 m³/h120-200 Pa38-45 dB(A)

L4 · Evaporator / Condenser Selection — LWAA Axial

Aluminum-alloy + composite hybrid blades with tip speed 30% below industry baseline. IP54 standard; IP55/66/68 customizable. 13 sizes cover 200-1000 mm.

ApplicationRecommended SizeAirflowStatic PressureConfiguration
Small evaporator / air-cooled cabinetLWAA-4001,500-4,200 m³/h50-150 PaMounting Ring
Medium condenser / heat pumpLWAA-5004,000-8,500 m³/h80-200 PaMounting Ring / Plate
Large condenser / air-cooled chillerLWAA-6307,500-13,000 m³/h100-300 PaCube Housing
Dry cooler / industrial ventilationLWAA-800/91012,000-22,000 m³/h150-400 PaCube Housing · IP66

Common Motor Platform · LWM EC Motor Platform

LWM is the common motor platform that powers the EC variants of LWBE3G / LWFC / LWAA — external-rotor brushless DC with integrated drive electronics, designed and manufactured in-house by LONGWELL.

SpecificationValueSpecificationValue
Power Range30 W - 2,200 W (paired to 4,400 W)Efficiency ClassIE4+ · 88-92%
Supply Voltage100-277 VAC (1ph) / 200-480 VAC (3ph)L10 Bearing Life≥ 60,000h @ 40°C · ≥ 40,000h @ 60°C
Control Interface0-10V · PWM 1-20kHz · Modbus RTU · BACnet MS-TPOperating Temp-40°C to +80°C · cold start -30°C
EMC ClassEN 55014-1/2 Class B · FCC Part 15 Class BProtectionsOver-current / over-temp / stall / phase-loss / DC bus over-voltage / brown-out recovery
System Integration · 10 ton RTU Reference BOM

Typical 10 ton Commercial RTU LONGWELL Configuration

The deployed 10 ton rooftop unit BOM at a Top-3 North American RTU OEM — a single RTU combines supply-air centrifugal + outdoor axial condenser fans on both sides, all driven by the LWM EC motor. One supplier, one commercial team, one spare parts library. Versus an AC solution, the per-RTU lifecycle (15 years) saves the end user USD 2,800+ in electricity.

Basis: 10 ton RTU, 2,500 cooling hours/year, $0.13/kWh commercial electricity, EC vs AC average power saving 35%.

Fan System Efficiency (AC baseline)
58%
Fan System Efficiency (LWM EC)
70-72%
LayerModelForm FactorQuantityUnit Power
L1LWBE3G-450 ECSupply-air Plug1 per RTU1.1 kW
L4LWAA-630 ECCondenser Cube2 per RTU0.85 kW
MLWM-EC1100EC motor platformCommon drive
Per-RTU Total3 fans2.8 kW
§3 · Certifications & Test Reports

Commercial HVAC Certification Matrix

All certificates are held by LONGWELL; original PDFs available on request. Gold-marked items carry the heaviest weight in commercial HVAC OEM supplier audits.

CertificationStandardCoverage
CEEU Marking · Machinery / EMC / LVDLWBE3G + LWFC + LWAA + LWM full range
UL UL 507 (fan) + UL 705 (axial) + UL 1004-1 (motor)Mainstream North American sizes covered
ETL Intertek mark · US/Canada NRTLMainstream North American RTU/AHU models
EMC Class BEN 55014-1 / EN 55014-2 Class BFull EC platform
FCCFCC Part 15 Class BFull EC platform
CCCChina Compulsory CertificationChina-market models
RoHS / REACHEU 2011/65/EU + (EC) 1907/2006Full LWBE / LWFC / LWAA / LWM
ErP Tier 2 EU Energy-related Products · Lot 6 / Lot 11Full EC platform · FMEI ≥ 0.62
DOE 2023 US DOE fan system efficiency ≥ 67%LWBE3G + LWAA EC fully compliant
AMCA 210AMCA 210-16 Performance StandardLONGWELL wind tunnel data + T3 equivalent evidence
ISO 9001 / 14001 / 45001Quality + Environment + Safety✓ Certified
BSCISocial Compliance Audit✓ Audited

Commercial HVAC Test Report Library

T1 = PDF delivered within 1 business day; T2 = scheduled at a named lab with a confirmed delivery date; T3 = equivalent evidence (same-series same-spec model report + engineering delta statement). T1-T3 services are complimentary for project-intent customers.

SeriesReport TypeModels CoveredIssuing LabStatus
LWBE3GUL 507 full coverage355/400/450/500/560/630 mmUL (Northbrook IL, USA)✓ T1 Ready
LWBE3GEN 60335-1 / EN 60335-2-80All 12 sizesTÜV SÜD (Germany)✓ T1 Ready
LWBE3GEMC: EN 55014-1/2Full EC rangeIntertek (Guangzhou)✓ T1 Ready
LWBE3GAMCA 210 performance test400/500/630 mmLONGWELL Wind Tunnel✓ T3 Equivalent
LWFCUL 507 / ETL146/180/225/280 mmUL · Intertek✓ T1 Ready
LWFCEN 60335 + EMCAll 10 sizesTÜV Rheinland✓ T1 Ready
LWFCNoise ISO 3744All sizesLONGWELL Anechoic Lab✓ T1 Ready
LWAAUL 705 / ETL400/500/630/800 mmUL · Intertek✓ T1 Ready
LWAAAMCA performance curves400/630/910 mmLONGWELL Wind Tunnel◐ T2 Scheduled Q3
LWMUL 1004-1 / EN 60034Full 30W-2.2kW rangeUL · TÜV SÜD✓ T1 Ready
LWMEMC full band + FCC Part 15All EC modelsIntertek · CESI✓ T1 Ready
LWML10 bearing life accelerated testLWM-EC600/1100/2200LONGWELL Aging Lab✓ T1 Ready
★ FLAGSHIP CASE · TOP-3 NORTH AMERICAN RTU OEM

Top-3 North American Commercial RTU OEM

Publicly listed company, USD 3B+ annual revenue, operations across US / Canada / Mexico, with owned manufacturing plants in the southern US and northern Mexico. Products applied in 3-25 ton commercial RTUs, heat pumps and rooftop air handling units. Customer name disclosable under separate NDA. Data reconciled by LONGWELL PMO and the customer's procurement team.

Project Context & Pressures · 2023 Q1

  • DOE 2023 mandate took effect — from 2023-01-01 the US DOE required commercial RTU fan system efficiency ≥ 67%. The customer's incumbent supplier could not deliver a compliant EC fan platform before the deadline.
  • Urgent search for an alternative supplier — hard requirements: full coverage across 6 RTU platform sizes, fan system efficiency ≥ 67%, noise ≥ 5 dB(A) below the prior solution, complete UL+ETL certification with DV/PV passed, mass production no later than 2023 Q3.
  • Industry development cycle out of control — competing suppliers quoted 12-18 month development cycles. The customer's product release window would be missed entirely, jeopardizing the 2023 selling season.

LONGWELL 90-Day NPI Timeline

WindowMilestoneActions
2023-02Spec LockCustomer engineering team visited LONGWELL HQ; 6-size spec review + risk assessment sign-off
2023-03CFD + DesignCFD across all 6 RTU platforms + biomimetic blade profile + customized scroll-mounting interface
2023-04Engineering Samples6-size samples delivered; customer factory DV initiated
2023-06DV/PV PassAll 6 sizes passed DV/PV first-attempt with zero rework
2023-08MP ReleaseMass-production process archived one month ahead of the Q3 deadline; first MP order placed

Technical & Commercial Outcomes

MetricRequiredAchieved
Fan System Efficiency≥ 67% (DOE 2023)70-72%
Noise Reduction (vs incumbent)≥ 5 dB(A)6.5 dB(A)
DV/PV Pass Rate≥ 95%100% first-attempt
Certification DeliveryUL + ETL 6 sizes100% delivered together
Mass-production Milestone2023 Q32023-08 (1 month early)
Annual production volume50,000+ units/year, stable for 30 months
Field quality incidentsZero major incidents · bearing FPM ≤ 80
Frame agreement3-year renewal in 2026 Q1
"LONGWELL was the only vendor who treated DOE 2023 as their problem too, not just ours. Their engineering team came to our facility three times in the first 30 days. The 90-day NPI cycle saved our season." — Procurement Director, Top-3 North American RTU OEM (disclosable after NDA)
§5 · Engineering Support

Commercial HVAC Engineering Support

LONGWELL provides commercial HVAC OEMs and BIM/MEP engineering teams with the tools and resources required to integrate LWBE3G + LWFC + LWAA + LWM — including application-specific selection tables, CFD service, BIM family library and reference BOMs.

ToolPurposeAccess
LONGWELLBUS SelectorInput AHU / RTU / FCU / evaporator-condenser operating point; returns 2-3 matching solutions with full P-Q-η curves + noise predictions + energy comparisonsFree download
Whole-Unit CFD SimulationCustomer uploads AHU/RTU geometry → LONGWELL simulates duct impedance, fan operating point, noise prediction, airflow uniformityFree for project-intent
3D CAD + BIM Family LibraryLWBE3G + LWFC + LWAA full STEP/IGES/Parasolid + Revit RFA family filesAvailable after NDA
BMS Register Map LibraryFull Modbus RTU + BACnet MS-TP register tables + Schneider/JCI/Honeywell/Siemens/Trane validated configsAvailable after NDA
Energy Code Compliance CalculatorExcel: input RTU/AHU capacity + current AC configuration → calculates DOE/ErP compliance margin after EC replacement + energy savings + payback periodFree
Quiet FCU Design GuideOffice / healthcare / education FCU quiet engineering guide · 12 LONGWELL-validated reference designsProject-intent on request

Field Application Engineering

For strategic commercial HVAC customers, LONGWELL provides 1-4 week deployment at the customer facility — completing first-batch AHU/RTU/FCU integration, DV/PV witness, and mass-production process transition. Local engineers available from EU / NA / Middle East offices. In the Top-3 RTU OEM case, LONGWELL engineers visited the customer's facility three times within the first 30 days.

90-Day NPI Process

Commercial HVAC 90-Day NPI Process

If standard configurations don't fully match your AHU / RTU / FCU platform requirements, LONGWELL offers the same 90-day NPI cycle that delivered the flagship Top-3 North American RTU OEM case — structured, predictable, validated.

StageEngineering ActionsCustomer Involvement
S1 · Day 1-14
Spec Lock
Application operating parameters + BMS integration requirements + certification matrix + timing windowProvide AHU/RTU/FCU operating points + regulatory class + timing window · 1-2 conference calls
S2 · Day 15-45
Design
Whole-unit CFD + biomimetic blade profile + 3D structure + communication register mappingLONGWELL leads. Customer receives CFD / 3D / BMS interface docs · one technical review
S3 · Day 46-70
Prototype
3-5 engineering prototypes + customer factory integration + DV3-5 prototypes; LONGWELL application engineers on-site for DV support; BMS integration debug
S4 · Day 71-90
Release
DV/PV completion + mass-production archived + first-order deliveryDV/PV verification; 48h closed-loop on engineering issues; first order 30-200 units

Commercial Terms

NRE Charge

USD 5,000-20,000 depending on complexity; 50% credited against the first mass-production order; Tier-1 customers negotiable.

Sample Fee

USD 150-600 per unit by size; 100% credited against mass-production order; stock standard models complimentary (limited quantity).

IP Ownership

Customer-specific design IP belongs exclusively to the customer; LONGWELL platform IP remains with LONGWELL.

First Order MOQ

50-200 units for standard models; first orders for new partnerships reducible to ~30 units to support internal validation.

Lead Time & Reliability Commitments

CommitmentTerms
Standard Model — Stock1-3 days · mainstream models stocked
Standard Model — MTO15-30 days · 50-200 units MOQ
Custom Model (post-NPI)30-45 days
Standard Warranty12 months from customer factory receipt date
Extended Warranty (EC critical parts)18-24 months, negotiable per frame agreement
L10 Bearing Life Commitment≥ 60,000h @ 40°C · ≥ 40,000h @ 60°C
8D Closed-Loop Response24h acknowledgment → 5 business day root cause → 15 business day corrective action + verification
Field SupportSerious quality events: LONGWELL engineer on-site within 48 hours
On-Time Delivery≥ 97% (12-month rolling average)
Payment TermsFirst order T/T 30% advance + 70% against B/L · strategic customers L/C / OA 30-60 days / Sinosure-backed OA 30-90 days
§4 · How to Engage

Three Engagement Paths

Three ways to move from this brochure to a working partnership. Pick the one that fits your current commercial HVAC project stage.

A
Quick Quote · 24h Response

Quick Quote

Send 5 parameters (airflow / static pressure / noise / supply voltage / certification) → receive 1-2 matching solutions + performance curves + indicative quote within 24 hours.

⏱ 24h response · No NDA required
Send Parameters →
B
Technical Deep Dive · 30 min

Technical Deep Dive

Book a 30-minute online technical meeting → LONGWELL application engineer + sales manager join → we prepare an application-specific solution comparison (CFD / BMS integration / energy-code compliance).

⏱ Booked within 1 week · NDA optional
Book Meeting →
C
Factory Audit + 90-Day NPI

Factory Audit + NPI Kickoff

Visit our Ningbo/Yuyao HQ → bilingual reception → production lines + QA lab + R&D center + customer hospitality. Optional simultaneous 90-day custom NPI kickoff.

⏱ Scheduled in 2-4 weeks · Strategic customers
Schedule Visit →
Dedicated Commercial HVAC Contact

Get in Touch

International Business sales@longwellfans.com Mark subject as "Commercial HVAC" for fast routing
Founder & CEO Bruce Li · bruce@zjlongwell.com Tier-1 commercial HVAC strategic relationships
Europe Office europe@longwellfans.com Serves European FCU / AHU brand customers
North America Office northamerica@longwellfans.com Serves Top-5 North American RTU/AHU OEMs
Middle East Office middleeast@longwellfans.com Serves Saudi / UAE / Qatar commercial-building MEP integrators
Headquarters www.longwellfans.com No. 100, South of Xuxiang River, Ditang District, Yuyao, Ningbo, Zhejiang 315400, China
LWBE3G + LWFC + LWAA + LWM

One supplier · Four series · Commercial HVAC code-ready

Engineered for the Critical. LONGWELL Fans Power Your Equipment. Full compliance with DOE 2023 · ErP Tier 2 · IECC 2024 · ASHRAE 90.1.