Agriculture Ventilation · Solution Pack · EN V1.0

Agriculture Ventilation
One-Stop Fan Platform

From the poultry house to the greenhouse to the vertical farm: dedicated 24–50 in exhaust fans, EC axial platforms to Ø1000 mm, EC backward-curved centrifugal, duct and tangential circulation fans — with the control interfaces (0-10 V / PWM / Modbus RTU / BACnet MS-TP) that modern climate computers expect.

Ø 190–1000 mm
EC PLATFORM SPAN
LWAE3G axial + LWBE3G centrifugal
24–50 in
DEDICATED EXHAUST RANGE
LWPV poultry & livestock series
60,000 h
L10 BEARING LIFE @ 40°C
ISO 281 verified, EC platforms
720
EC FANS IN ONE CEA BUILD
8,000 m² · 12-tier rack reference case
Why LONGWELL

Why LONGWELL for Agriculture Ventilation

Agriculture is not a souped-up HVAC duty. It is humidity swings, ammonia, dust, washdown, 24/7 part-load operation and electricity bills that decide farm margins. We build the platform around those five realities.

01
EXHAUST PLATFORM

24–50 in Poultry & Livestock Exhaust

LWPV is purpose-built agricultural exhaust hardware — cone and discharge variants sized in inches the way barn builders buy: 24, 29, 30, 36, 44, 50 in. Three sub-series: LWPVE poultry, LWPVB large-diaphragm, LWPVA compact.

LWPVE-600(24″) → LWPVB-1270(50″) · 18 frame variants
02
BIOMIMETIC EC EFFICIENCY

EC Where It Pays

LWBE3G bionic backward-curved impellers run 4–6 dB(A) quieter than conventional wheels, cut high-frequency sound pressure 50%+ and save 8–12% energy — with +25–30% stall margin for dusty ag airstreams.

Static efficiency 73–82% · ≤1,800 Pa · 500–30,000 m³/h
03
AMMONIA / HUMIDITY / DUST

Built for the Barn Environment

Agricultural air corrodes. EC platforms offer IP44 through IP68 variants, IP-code verified to IEC 60529, with −25°C cold-start reporting — the combination barns, greenhouses and stores impose.

IP44 / IP54 / IP55 / IP66 / IP68 · IEC 60529 · −25°C report
04
CLIMATE-COMPUTER READY

Controls That Talk to the Barn

Precision livestock farming runs on controllers reacting to temperature, humidity, CO₂ and NH₃. LONGWELL EC fans ship with 0-10 V / PWM / Modbus RTU / BACnet MS-TP standard, CANopen optional.

PF > 0.95 · 100–277 VAC 1∅ / 200–480 VAC 3∅ · 12 protections
05
ONE SUPPLIER, FULL BOM

Whole-House Airflow From One Factory

Exhaust, tunnel, circulation, duct, rack-level and storage-drying airflow from one plant: LWPV, LWAE3G, LWBE3G, LWAA, LWDA, LWCA, LWAC450. Shared register maps = one integration effort.

7 families · MOQ 100–500 pcs · lead time 15–30 days
What's Inside

What's Inside This Pack

Six sections, written the way an agriculture engineer buys: duty first, part numbers second, honest boundaries third.

Pack at a glance

  • Application segments6
  • Product families mapped7
  • Certifications held11
  • Segment deep dives4
  • Reference case1 + 3 evidence threads
  • Catalog basisPrint 2025.8.20 · A2
  1. §16 Agriculture Segments
    Barn, dairy, greenhouse, storage, vertical farm, aquaculture
  2. §2Product × Application Matrix
    7 families mapped to duty, with model numbers
  3. §3Segment Deep Dives
    Challenges + recommended configurations
  4. §42026–2030 Trend Radar
    Sourced market data: AC→EC, IoT, CEA, regulation
  5. §5Certifications & T1 Test Library
    What we hold, what we do per project
  6. §6Reference Case: 8,000 m² Vertical Farm
    720 EC fans, +18% yield, 3 verified evidence threads
Fastest path. Building or retrofitting a poultry / swine house → deep dive: barn, then the LWPV frame table in §2. Writing a greenhouse or vertical-farm business plan → §5 has the sourced numbers. Assessing a CEA build → the 8,000 m² LED hot-zone case.
§1 · Application Architecture

6 Agriculture Segments, One Platform Logic

Each segment differs in static pressure, duty cycle and corrosion exposure — but they share the same EC control layer, which is what makes a single-supplier BOM practical.

P

Poultry & Swine House Exhaust

Tunnel and cross-ventilation wall exhaust, 24–50 in class, continuous duty at part load with high static pressure in tunnel mode.

LWPVE · LWPVB · LWPVA
D

Dairy & Large Barn Ventilation

High-volume exchange plus interior circulation for heat-stress control; milk yield is directly airflow-sensitive.

LWAE3G EC axial · LWBE3G355 · LWPV
G

Greenhouse Air Movement

Horizontal airflow along the canopy, gutter circulation, inlet and duct distribution; condensation control without leaf wetting.

LWAC450 · LWDA duct · LWAA / LWAE3G250
H

Harvest & Post-Harvest Storage

Field-heat removal, pile drying, pre-cooling and ripening rooms — high-humidity cycles and long unattended runs.

LWAE3G · LWBE3G centrifugal
V

Vertical Farming & Grow Rooms

Layer-by-layer uniform airflow, compact envelopes, low noise in occupied buildings, LED-loop heat pickup.

LWCA-40 tangential · LWBE3G · LWAE3G
A

Aquaculture & Seafood Processing

Aeration blower duty and processing-room ventilation in humid, salt-laden air; reliability margins matter more than peak efficiency.

LWBE3G · LWAE3G · IP variant selection
§2 · Platform Mapping

7 Product Families × Agriculture Duty

Released part numbers, grouped by the job they actually do. Where a family is offered in several frames, the frame list is the quote list.

LWPV Series
Agricultural Exhaust · 24–50 in
  • LWPVE (poultry exhaust): LWPVE-600(24″)T-03, LWPVE-800(29″)T-03, LWPVE-800(29″)U-02, LWPVE-900(30″)T-01/T-02, LWPVE-900S-04, LWPVE-1000(36″)T-01/T-03, LWPVE-1220(44″)T-01/T-02, LWPVE-1295S-05
  • LWPVB: LWPVB-915(36″)T(S)-01, LWPVB-1270(50″)T(S)-01
  • LWPVA: LWPVA-560T(S)-01, LWPVA-560S-01, LWPVA-660T(S)-01, LWPVA-660S-01, LWPVA-850T(S)-01, LWPVA-850S-01, LWPVA-1060S-01
LWAE3G Series
EC Axial · Ø200–1000 mm
  • Airflow 800–32,000 m³/h · static 90–400 Pa
  • Power 30–2,200 W · IE4+ · 85–92% efficiency · 13 sizes
  • 0-10 V / PWM / Modbus RTU / BACnet MS-TP · CANopen optional
  • Noise 32–65 dB(A) · L10 60,000 h @ 40°C
  • Barn exchange, greenhouse inlet, storeroom aeration
LWBE3G Series
EC Backward-Curved Centrifugal
  • Ø190–710 mm · 12 sizes · 500–30,000 m³/h · ≤1,800 Pa · 130 W–7.2 kW
  • Bionic impeller: −4–6 dB(A), −50%+ HF noise, −8–12% energy, stall margin +25–30%
  • Agriculture-released: LWBE3G355-102NS-24 / -102NT-25 / -188NT-26 / -138NT-27 / -188NT-29; LWBE3G190-072PS-02 / -072PS-12 (bracket)
  • Static efficiency 73–82% · L10 60,000 h @ 40°C
LWAA / LWAE3G250
External-Rotor Axial · 250 mm · AC / EC
  • LWAA2E250S-7MKB-19 · LWAA4E250B-5MEW-23 (AC)
  • LWAE3G250SS/ST EC variants: -7PNW-07, -7PKW-08, -7PNW-09, -7PKW-10, -7MNW-01, -7MNW-02, -7MEW-03, -7MEW-04, -7MGW-05, -7MGW-06
  • Grow tents, farm livestock ventilation, packaged equipment
LWDA Series
AC Plastic Duct Fans · 6.3″ / 8″
  • LWDA-160(6.3″)S-PBN-002 / -002S
  • LWDA-200(8″)S-PBN-001 / -002 / -002S
  • Plastic housing for humid greenhouse and grow-tent duct runs; cost-efficient distribution layer beneath EC primary ventilation
LWCA-40 & LWAC450
Tangential (Cross-Flow) Fans
  • LWCA-40290 (LWCA-40 series, 40 mm): planting tents, hydroponic rack airflow
  • LWAC450: wide-format greenhouse circulation — released reference: 280 units in a 32-hectare Dutch greenhouse
  • Even air curtain across the full canopy or tray width

Segment × Platform Mapping Matrix

Agriculture segmentPrimary platformSupporting platformsEngineering note
Poultry house exhaust (tunnel / cross)LWPVE / LWPVB 24–50 inLWPVA for compact housesT-frame cone variants for tunnel houses; match frame count to the house static-pressure plan
Swine & dairy barn exchange + circulationLWAE3G Ø630–1000LWPV exhaust · LWBE3G355 pit/boostDemand-driven 0-10 V / Modbus control trims energy at part load, where most barn hours sit
Greenhouse circulation & distributionLWAC450 tangentialLWDA duct · LWAA / LWAE3G250 axialTangential curtain airflow avoids leaf flutter; the duct layer handles row-level distribution
Harvest & post-harvest storageLWAE3G EC axialLWBE3G centrifugal for ducted / filtered dutyHigh-humidity cycling duty; select IP variant by washdown regime
Vertical farming & grow roomsLWBE3G Ø200–500 ECLWCA-40 tangential · LWDA50 compact fans per rack beat 25 larger fans at equal total airflow (see reference case lessons)
Aquaculture & seafood processingLWBE3G centrifugalLWAE3G axialSpec IP54+ and coated options; marine-humid air, continuous duty
§3 · Segment Deep Dives

Four Segments, Requirement by Requirement

The three things that actually go wrong in each segment, and the configuration that answers them.

Poultry & Swine House Ventilation

Tunnel + cross-ventilation wall exhaust. Fan electricity is the largest controllable cost in an enclosed barn; part-load behaviour decides the bill.

01

Heat stress eats productivity

Broiler weight gain, egg output and milk yield drop under heat waves; tunnel houses need dependable exchange at high static pressure, not nameplate peak flow.

02

Ammonia & welfare rules

EU welfare codes and emissions limits push toward better-controlled airflow; fixed-speed fans cycling on/off cannot follow the curve.

03

Dust, feathers, washdown

Impellers foul and housings get hosed. Corrosion protection and IP selection decide year-3 performance, not year-1 brochures.

RequirementRecommended configurationWhy
Wall exhaust 24–36 in classLWPVE-600(24″)T-03 / LWPVE-800(29″)T-03 / LWPVE-900(30″)T-01/T-02 / LWPVE-1000(36″)T-01/T-03T cone variants for tunnel duty; S variants for standard discharge
Large-house primary exhaust 44–50 inLWPVE-1220(44″)T-01/T-02 · LWPVB-1270(50″)T(S)-01 · LWPVE-1295S-05Fewer, larger fans cut wall penetrations and wiring points per house
Demand-driven exchangeLWAE3G EC axial Ø630–1000 with 0-10 V / Modbus RTUVariable speed follows the climate controller instead of cycling; EC vs fixed-speed savings are the core of barn-ventilation economics
Interior circulation / pit boostLWBE3G355-102NT-25 / -188NT-26 / -188NT-29Bionic EC centrifugal, −4–6 dB(A); quieter barns are calmer livestock
Cold-climate start−25°C cold-start T1 report on requestUnheated houses still need ventilation in northern winters

Frame-level P-Q curves are issued per part number from the AMCA 210 / ISO 5801 bench — send the house static-pressure plan and we return curves per frame.

Greenhouse Ventilation & Circulation

Uniform canopy airflow, condensation control, integration with screens and cooling pads. China alone maintains more than 2 million hectares of protected horticulture.

01

Temperature gradients

Horizontal airflow must equalize the canopy line without leaf flutter that drives transpiration stress and disease pathways.

02

Humidity & condensation

Stagnant zones grow fungus. Continuous low-velocity circulation beats intermittent blast ventilation for fungal-pressure control.

03

Corrosive, humid electrics

Misting, fertilizer vapours and 24/7 duty punish open-frame motors; plastic duct hardware survives where sheet metal rusts.

RequirementRecommended configurationWhy
Canopy-length air curtainLWAC450 tangential circulation fanEven, gentle airflow band along the row; reference-proven in a 32 ha Dutch greenhouse
Row / duct distributionLWDA-160(6.3″)S-PBN-002 / LWDA-200(8″)S-PBN-001/002/002SPlastic housing, humidity-tolerant, low cost at distribution scale
Inlet / gable exchangeLWAA2E250S-7MKB-19 · LWAA4E250B-5MEW-23 · LWAE3G250SS/ST variants250 mm external-rotor axial: AC for budget builds, EC where control is wanted
Primary exchangeLWAE3G EC axial Ø450–100090–400 Pa class covers pad-and-fan greenhouse static pressure

Harvest & Post-Harvest Storage

Field-heat removal, pile drying, pre-cooling, ripening rooms. Long unattended cycles in high-humidity air — and shelf life depends on them.

01

Drying without overdrying

Airflow per cubic metre of storage must be metered by stage; fixed speed either under-delivers early or over-dries the pile edge.

02

Humidity cycling

Condensation on cold surfaces followed by warm moist cycles is standard duty; IP and insulation class are not optional.

03

Unattended reliability

A failed fan in an onion or potato store is a write-off event; bearing life and monitoring feedback carry direct economic weight.

RequirementRecommended configurationWhy
Free-flow storage aerationLWAE3G EC axial (duty-dependent size)IE4+ efficiency at 90–400 Pa; speed control stages the drying curve
Ducted / filtered dutyLWBE3G EC centrifugal Ø355–710Up to 1,800 Pa static for filters, coolers and long duct runs
Monitoring & protectionModbus RTU / BACnet MS-TP feedback + 12 built-in protectionsThe controller sees the fan, not just a relay; alarms before the pile is at risk
Packaged equipment OEMLWBE3G190-072PS-02 / -072PS-12 (bracket)Bracket-mounted 190 mm EC centrifugal for dehumidifiers and storage HVAC

Vertical Farming & Grow Rooms

Layer airflow, LED-loop heat pickup, dehumidification coupling — inside buildings where people work and noise is a lease clause.

01

Uniformity across trays

Low-velocity, evenly distributed airflow prevents microclimate layers between rack levels; cross-flow geometry is naturally suited.

02

Noise in occupied space

Grow rooms sit inside urban buildings and run 18–24 h; tonal high-frequency noise is the usual complaint driver.

03

Biofilm in wet housings

Mushroom and leafy-green chambers historically suffer 12–18 month housing biofilm contamination — then annual replacement.

RequirementRecommended configurationWhy
Rack-level uniform breezeLWBE3G Ø200 EC, 50 units per rackCFD-derived: 50 compact fans/rack outperform 25 larger fans at equal total airflow
LED hot-zone heat rejectionLWAE3G Ø500 EC axial, IP55Heavy continuous duty with CO₂ enrichment tolerance
Rack / tent airflowLWCA-40290 tangential · LWDA-160/200 ductEven low-velocity sheet flow at slim envelope and low noise
Housing hygieneAnti-fungal coated housings (silver-ion / copper-ion polymer + epoxy + ED-coat)Standard on the CEA build in the reference case; eliminates the 12–18 month replacement cycle
§5 · Evidence Layer

Certifications & T1 Test Report Library

What we hold today, what is done per project, and — explicitly — what is not yet in scope.

Certifications held today

CEEMC EN 55014-1/-2 Class BLVD 2014/35/EUUL 1004-1 + UL 507ETLFCC Part 15 Class BCCCRoHS / REACHErP Tier 2ISO 9001 / 14001 / 45001BSCI

IP variants across the EC platforms: IP44 / IP54 / IP55 / IP66 / IP68, verified to IEC 60529.

T1 reports — issued within 1 working day

  • AMCA 210-16 / ISO 5801 — P-Q curves (the baseline document for barn and greenhouse duty-point selection)
  • ISO 3744 / ISO 13347 acoustics · ISO 14694 / ISO 10816 vibration
  • ISO 281 — L10 life (basis of the 60,000 h @ 40°C claim)
  • UL 1004-1 / CSA · EMC full band · IEC 60529 IP · −25°C cold start
  • Planned T2 ISO 9227 / ASTM B117 salt spray 96 h · ATEX — not yet in scope; flagged rather than implied
§6 · Reference Case · Vertical Farming

8,000 m² Vertical Farm LED Hot-Zone HVAC · 720 EC Fans

A composite reference case built from representative urban vertical-farming facility builds: anti-fungal coated IP55 axial fans for LED hot-zone HVAC, plus compact circulation blowers for 12-tier grow racks — hitting an urban noise ordinance and +18% yield versus the prior airflow design.

COMPOSITE REFERENCE CASE · CEA

720 EC fans, 12 tiers, one noise ordinance

Project size8,000 m² · 12-tier grow rack · 720 EC fans + 120 HVAC axial
Reference periodComposite reference · 2024–2026 build pattern
GeographyEU + North America urban vertical farm segment
LED lighting density of 700 W/m² means 50–70% of it becomes heat that must be removed — 300–500 W/m². The fans are not an accessory to the grow room; they are the thermal and acoustic envelope of it. Engineering framing, vertical farming · LED hot-zone segment

1 · Challenge

  • LED grow lights at 700 W/m² total lighting density — 50–70% becomes heat that must be removed (300–500 W/m²).
  • Grow zone 22–24°C / 65–85% RH / 1,500 ppm CO₂ enrichment, 24/7 continuous duty.
  • Mushroom and leafy-green chambers historically suffer 12–18 month fan-housing biofilm contamination — replaced annually.
  • Urban acoustic constraint at the fenceline; rack-level circulation must give a uniform leaf-level breeze with no stagnant zones across 12 tiers.

2 · Solution architecture & bill of materials

120 LWAE3G-500-IP55-Coated units on LED hot-zone HVAC heat-reject and return-air paths; 600 LWBE3G-200-EC-Coated units in grow-rack manifolds for uniform leaf-level breeze across the 12-tier rack. Anti-fungal coating (silver-ion or copper-ion infused polymer + epoxy + ED-coat) on all housings as standard — eliminating the biofilm cycle that traditionally forces 12–18 month replacement.

LONGWELL SKUTypeQtyKey spec
LWAE3G-500-IP55-CoatedEC axial HVAC fan120 unitsØ500 mm · IP55 · anti-fungal coating standard · −40°C to +60°C ambient · 1,500 ppm CO₂ continuous tolerance
LWBE3G-200-EC-CoatedCompact rack-level circulation blower600 units (50/rack × 12)Ø200 mm · anti-fungal coating standard · IP55

3 · Modelled outcomes — typical range

+18%
Crop yield vs prior airflow design
−22%
Annual HVAC + circulation energy
38 dB(A)
At 4 m fenceline, under the 42 limit
0
Biofilm events in 24-month service
>60,000 h
Continuous-duty L10 at 24/7, 80% load
1,500 ppm
CO₂ enrichment, continuous, no drift

How to read these figures: the values above are modelled for this composite scenario — a planning range, not measured results from one named project. Verified project evidence is in section 6 below.

4 · Implementation timeline

StageWhat happened
Month 0Facility build commits to anti-fungal coating standard
Month 1Sample units to the facility commissioning team
Month 2PO for 120 + 600 units
Month 3First batch ships, 4 weeks production
Month 4Facility installation and commissioning
Month 18+18% yield improvement validated against the prior comparable facility design

5 · Engineering lessons

  • Anti-fungal coating as standard — not an optional add-on — was the single biggest predictor of long-term reliability in CEA service. Prior installations with coating as an option ran 12–18 month replacement cycles; on this build, zero biofilm events in 24 months.
  • Uniform leaf-level breeze across the 12-tier rack was the single biggest yield driver. CFD showed 50 compact fans per rack outperforming 25 larger fans at the same total airflow.
  • +18% yield recovered the fan CapEx in 5 months — far faster than an energy-savings case alone would justify.
  • 38 dB(A) at 4 m fenceline met the urban noise ordinance for a downtown site, which removed the suburban-siting and transport penalty from competing designs.
  • 1,500 ppm continuous CO₂ (with bursts to 3,500 ppm during fertilization) was validated on the motor electronics — no degradation after 24-month service.

6 · Verified project evidence

Everything below is drawn from actual project correspondence. Model numbers, duty points and certification basis are stated as they occurred. Customer names are withheld; no pricing is published.

Zimbabwe — FAO agricultural ventilation programme

DELIVERED
AC AXIAL · UN FAO PROJECT

Supplied LWAA4E400S-5MEB-21 — Ø400 mm AC axial fan, 220 V 50 Hz, 180 W, 0.85 A, 1,350 rpm, IP44, Class F, 6 µF, with wire guard.

Delivered under a United Nations FAO project, which meant third-party inspection and documentation had to be right before despatch — the fan spec was never the difficult part. CE and EAC marks on the rating plate; the label carries the product URL for field verification.

United States — vertical farming rack ventilation

SAMPLING
DC CROSS-FLOW · EVALUATION

Why cross-flow: a growing rack needs an even air curtain along the full tray width, which is what a tangential wheel produces — an axial fan gives a jet with dead zones at the tray ends.

Custom guards and mounting brackets were evaluated with the fan so the assembly drops straight into the rack frame.

Australia — agricultural drying equipment

DELIVERED
EC BACKWARD-CURVED · COMPACT UPGRADE

High static duty in a compact upgrade: the replacement had to hold pressure through a loaded drying bed while fitting the existing cabinet.

The AC axial fan supplied for a greenhouse and agricultural ventilation programme — LWAA4E400S-5MEB-21, 220 V 50 Hz, 0.85 A, 180 W, 1,350 rpm, IP44, Class F, 6 µF, CE and EAC marked, build date 2024.11 — shows the same rule: grow-room and greenhouse ventilation runs continuously in warm, humid, high-dust air, so IP class and insulation class matter more than peak airflow.

Fan performance figures are quoted from LONGWELL controlled datasheets and tested per AMCA 210/211 methods; third-party reports available on request. EC versus AC energy saving is approximately 30%, higher under strongly varying load — confirm against your own load profile. Final selection must be confirmed against the actual duty point (airflow / static pressure / voltage / control method) and project validation.

Case source: longwellfans.com · use case: vertical-farming-led-hot-zone

How We Work

From Duty Point to Released Part Number

Four steps, no mystery: you send the duty, we send the hardware documentation, you verify on your own site.

1

Send the duty point

Airflow (m³/h or CFM), static pressure (Pa or in. wg), supply voltage, control interface, and the environment: humidity, ammonia exposure, washdown regime.

2

We answer with hardware

A model, a measured P-Q curve (AMCA 210 / ISO 5801), an installation drawing and the documents that belong to that part number — within the week for standard frames.

3

Sample & verify

Stocked sizes ship samples in 1–3 days. You verify on your own house, greenhouse or storage test bay against your climate controller.

4

Mass production

MOQ 100–500 pcs by size · production lead 15–30 days · standard warranty 12 months (extendable 18–24 by agreement) · design life 10 years.

Engagement Paths

Four Ways In

Pick the path that matches your project stage — each one starts with a document you already have.

A
BARN SYSTEM OEM

Ventilation-House & Housing Manufacturer

Send house static-pressure plans and the frame schedule. We map LWPV frames plus LWAE3G EC exchange to each house class, with curves per frame and a consolidated BOM.
Needs: house drawings + frame schedule
B
CEA INTEGRATOR

Greenhouse & Vertical Farm EPC

Send canopy or tray-level airflow targets per zone. We configure LWAC450 / LWDA / LWCA-40 layers plus primary LWAE3G exchange, with part-load energy comparisons included.
Needs: zone airflow targets + ceiling height
C
OEM UPGRADE & REPLACEMENT

Incumbent Fan Replacement

Send the incumbent part number (any brand) and the duty point. We return the LONGWELL counterpart with measured curves — or tell you honestly if the duty sits outside our released range.
Needs: incumbent SKU + duty point
D
STORAGE EQUIPMENT OEM

Post-Harvest & Drying Equipment

Send the ducted or filtered duty. LWBE3G + LWAE3G selection with the right IP variant, protection feedback and monitoring interface matched to your controller.
Needs: duct pressure + controller protocol
Contacts

Agriculture Ventilation Sales Contacts

General Salessales@longwellfans.comQuotations, MOQ, lead times, samples
Online Fan Selectorselect.longwellfans.comSelf-serve platform selection, then send us the duty point

Send us the duty point. We answer with a model, a curve, a drawing and the documents.

What to send for a same-week answer:

  • Airflow and static pressure at the design duty point (m³/h + Pa, or CFM + in. wg)
  • Supply voltage and control interface (0-10 V / PWM / Modbus RTU / BACnet MS-TP)
  • Environment: humidity, ammonia / washdown exposure, ambient temperature range
  • Application: barn exhaust / greenhouse circulation / storage aeration / rack-level
  • If replacing an incumbent: the current part number (any brand) and what you dislike about it
  • Target certifications and destination market (EU / NA / APAC)
Email LONGWELL Team Open the Fan Selector
NINGBO LONGWELL ELECTRIC · Fans & motors since 1990 · Ningbo, China · exported to 30+ countries longwellfans.com · Agriculture Solution Pack EN V1.0