OEM & ODM Partner Program

Blower OEM Solutions for
HVAC & Equipment Manufacturers

LONGWELL supplies custom AC, DC and EC fans and blowers for equipment manufacturers. Share airflow, pressure, installation space and control requirements to start your OEM project.

20+
Years of Export
Experience
30+
Countries Served
Worldwide
5M+
Units Produced
Annually
8
Global Sales
Regions

Powering Your Products with Precision Engineering

We (LONGWELL) specialize in providing OEM solutions and building long-term partnerships with businesses worldwide. With deep expertise in product development, manufacturing, and innovation, we help our partners succeed in highly competitive markets by delivering tailored solutions that meet their unique needs.

Match the blower family to your equipment

LONGWELL supplies fan and blower configurations for equipment manufacturers developing air-handling units, packaged HVAC equipment, air-side data-center cooling and industrial ventilation. Start with the installed duty point and layout, then review the impeller, drive and motor configuration together.

Commercial blower families for an OEM engineering review
LONGWELL familyConfigurationTypical equipment applicationIntegration details to review
DD / DDMDirect-driven, forward-curved centrifugal blowersFan-coil units, packaged air conditioning and AHUsRequired airflow and pressure, inlet arrangement, motor supply and cabinet space
ATBelt-driven, forward-curved centrifugal blowersAHU fan sections and projects using an external motor and belt driveMotor and drive selection, pulley ratio, discharge orientation and service access
RLM / EC plug fansBackward-curved configurations, including casingless plug-fan arrangementsAHU plenums and CRAH/CRAC air-side cooling equipmentInlet clearance, plenum geometry, mounting frame, speed commands and feedback
REM / TEMBackward-curved centrifugal blower familiesHVAC and equipment air paths with filters, coils or duct resistancePerformance across the operating range, motor/controller configuration and acoustic limits

Compare the exact model’s curve, drawing and electrical specification with your equipment requirements. Use the LONGWELL Fan Selector to explore models, or browse the product catalogs and drawings.

Specifications to send for an OEM blower proposal

A useful blower specification pairs airflow with pressure at the same operating condition. Send the requirements below, together with a system sketch, existing model number or installation drawing when available.

Project inputs for selection, customization and quotation
SpecificationWhat to provideEngineering review
Airflow and pressureRequired m³/h or CFM, pressure in Pa or in. w.g., and whether the pressure is static or totalMatch both values at the duty point; include the operating range and clean/loaded-filter conditions
Electrical supplyAC voltage, phase and frequency, or DC voltage; supply tolerances and input-power limitsSelect a compatible motor and drive configuration
Control and feedbackRequired speed command, such as 0–10 V, PWM or Modbus, plus speed feedback and alarm needsConfirm the exact model’s interface, signal levels and control behavior
Installation envelopeAvailable length × width × height, inlet/outlet dimensions, fixing points and discharge directionReview casing, bracket, inlet clearance and access for installation and maintenance
Operating environmentAir and ambient temperature, humidity, dust or corrosive exposure, and required protection levelConfirm materials, motor protection and suitability for the actual environment
Sound requirementsNoise limit, operating point, measurement distance and whether the limit is sound pressure or sound powerCompare acoustic data on a consistent measurement basis
Project and complianceTarget market, required standards or approvals, sample quantity, annual forecast and launch scheduleAgree the documents, validation scope and commercial proposal for the selected configuration

Maximum airflow and maximum pressure are different endpoints on a fan curve. For a useful comparison, request airflow, pressure, input power and sound data for your required duty point. The airflow unit converter helps align CFM and m³/h specifications.

Send your blower specification

Define customization before approving a sample

LONGWELL’s OEM review brings the fan, motor and equipment interfaces into one specification. Depending on the chosen family, the review can cover casing and outlet orientation, mounting dimensions, motor supply, speed control, cable and connector requirements, and product labeling.

  1. Define the duty. Share airflow, pressure, environment, installation space and the equipment’s operating conditions.
  2. Agree the configuration. Review the proposed family, curve, mechanical drawing, electrical interface and requested customization.
  3. Validate the sample in your equipment. Check installed airflow, sound, temperature and control response against the agreed acceptance criteria.
  4. Release the production specification. Confirm the approved drawing, bill of materials, inspection requirements, labeling and order plan before series supply.

Four Reasons Partners Choose Longwell

🎯

Tailored Solutions

Customized products and services precisely designed to meet your specific market demands and brand requirements.

✅

Quality Assurance

Strict quality control at every production stage, backed by ISO9001, ISO14001, CE, UL/ETL, and BSCI certifications.

⚡

Technological Expertise

Advanced EC motor technology, CFD simulation, and aerodynamics applied to deliver high-efficiency, high-performance fans.

🌍

Global Reach

8 regional sales organizations and a global network of partners ensure smooth collaboration and on-time delivery worldwide.

Advanced Technology, End-to-End Service

EC Motor & Aerodynamics Leadership

Our R&D team applies advanced EC motor drive technology, aerodynamics principles, and CFD simulation to achieve high efficiency and precise airflow control — delivering significant breakthroughs in energy utilization for your OEM products.

Full-Spectrum OEM Services

From initial design to mass production, we handle every stage with precision. Our experienced team works closely with you to ensure seamless project execution, whether you need small batch runs or high-volume production.

High-end CustomizationHigh-Efficiency EC MotorHigh Cost-Performance RatioOEM / ODMCFD SimulationCE / UL / ETL Certified
Longwell OEM Capabilities

Your OEM Journey — 4 Steps to Production

1

Product Design & Development

Using advanced design tools and CFD simulation to create bespoke, high-performance fan products tailored to your specifications.

2

Prototyping & Testing

Rapid prototyping and rigorous performance testing to validate quality, efficiency, and noise standards before mass production.

3

Scalable Manufacturing

Efficient, scalable production using advanced automation machinery — small batch or high-volume, with consistent quality.

4

Supply Chain & Delivery

Full supply chain management ensuring timely global delivery and effective resource coordination with protective packaging.

Fan Solutions Across 15+ Application Sectors

Ventilation
Ventilation System

 

Air conditioning
Air Conditioning

 

Refrigeration
Refrigeration

 

Heating
Heating

 

Electronics
Electronics Technology

 

Rail Transit
Rail Transit

 

Medical
Medical Technology

 

Home Appliances
Home Appliances

 

Data Center
Data Center

 

Fan Grid
Fan Grid System

 

AHU
AHU

 

FFU
FFU / EFU

 

Air Purifier
Air Purifier

 

Heat Exchanger
Heat Exchanger

 

Drive Technology
Drive Technology

 

Mechanical
Mechanical Equipment

 

Blower OEM solutions: frequently asked questions

What does an OEM blower solution include?

It combines a blower configuration with the mechanical, electrical and control interfaces required by your equipment. LONGWELL reviews the fan family, duty-point performance, installation drawing, motor and requested customization, then agrees the sample and production requirements with your team.

Can LONGWELL supply AC, DC and EC blower options?

Yes. LONGWELL offers AC, DC and EC fan and blower product lines. Available motor options depend on the family and exact model. Send your supply voltage, airflow, pressure and control requirements so engineering can propose a suitable configuration.

Can you customize the housing, mounting and controls?

Yes. The OEM review can address casing and outlet orientation, mounting dimensions, motor selection, cables, connectors and control requirements. The agreed scope is recorded in the proposed drawing and specification for the selected product family.

Can LONGWELL provide a replacement for an existing blower?

Yes. LONGWELL can propose replacement candidates for existing blower applications. Share the current model number, nameplate, curve and installation drawing. Confirm the final choice against the duty point, supply and controls, mounting dimensions, sound limits and equipment validation requirements.

What information is needed for a quotation and sample review?

Send airflow and pressure at the required operating point, electrical supply, available space, inlet/outlet layout, control and feedback needs, operating environment and target-market requirements. Include sample quantity, expected annual volume and project timing. The engineering team uses this brief to review the candidate configuration and supporting documents.

What are the MOQ, sample timing and production lead time?

These depend on the selected model, customization, validation work and order plan. Request a project quotation with your sample quantity, forecast and launch schedule; the commercial proposal will confirm quantities, sample arrangements and the production schedule.

Ready to Start Your OEM Partnership?

Tell us your project requirements. Our engineering team provides after-sale support and replies within 1 business day.