LONGWELL / Agricultural ventilation

Fans for Seasonal Livestock Building Ventilation

Livestock buildings need ventilation arrangements matched to the animals, building geometry and seasonal conditions. Work from the facility designer’s minimum and warm-weather airflow requirements, then select fans with the intake system. Dust, moisture, cleaning and service access are part of the equipment specification.

Minimum ventilationWarm-weather exchangeCleaning exposure
Wall-mounted exhaust assemblies with outlet cones and guards
Exhaust fan assembly formats. Review the inlet arrangement and resistance of the complete installation.
01 / Application & operating conditions

Review the complete inlet and exhaust arrangement

Tunnel, chimney and wall-exhaust layouts place different demands on a fan. This page helps equipment suppliers prepare the operating points, control sequence and environmental requirements for those arrangements. Internal circulation can be considered separately where the facility design calls for additional air movement within occupied areas.

WATCH THE APPLICATION PRINCIPLE · ENGLISH

How exhaust fans ventilate a poultry house

In warm-weather tunnel ventilation, exhaust fans create a pressure difference across the house. Air enters through controlled openings at the far end, passes the occupied space and leaves at the fan wall. An unintended leak shortens that route.

English narration and on-screen captions · 82 seconds · Equipment and flow paths are schematic.

Product scope in this film: Evaluate the LONGWELL poultry exhaust family with the complete inlet, shutter and building resistance. This is a qualitative airflow example, not a set of livestock-management targets or an exact model selection.

Explore the LONGWELL fan family  ·  Share your equipment and air-path requirements

01

Cover minimum and warm-weather duties

Provide the ventilation schedule from the livestock-building designer, including the range between minimum operation and warm-weather demand. Review inlet positions and the pressure required to distribute air as intended. Select fan stages or speed ranges that can be evaluated across those conditions, rather than only at maximum airflow.

  • Minimum and warm-weather airflow schedule
  • Intake positions and building pressure requirement
  • Staged or variable-speed operating points
02

Choose the fan assembly for the air path

Wall exhaust, tunnels and chimneys have different mounting and resistance requirements. Include shutters, guards, ducts and other restrictions in the selection. Where circulation fans are proposed, define their separate task and positioning so they do not become a substitute for the required outdoor-air exchange.

  • Wall, tunnel or chimney arrangement
  • Shutters, guards and duct resistance
  • Separate circulation layout where required
03

Specify cleaning, exposure and service access

Describe dust, moisture, corrosive exposure and the cleaning chemicals or wash process. Confirm materials, enclosure requirements and maintenance instructions for the selected assembly. Agree how fan faults will be indicated to the building controls and how a unit can be accessed for inspection or replacement.

  • Dust, moisture and cleaning exposure
  • Materials and configuration-specific protection needs
  • Fault indication and safe maintenance access
02 / Product routes for this application

Match the fan family to the equipment.

Compare the proposed model at the required airflow and pressure, then check the installation and control interface.

Wall-mounted exhaust assemblies with outlet cones and guards

Agricultural exhaust assemblies

Review agricultural exhaust assemblies against the building’s intake arrangement and ventilation schedule. Confirm mounting, restrictions and the selected motor or controller configuration before ordering.

Explore this fan family →
Circulation fan with suspension bracket and guard

Circulation fan assemblies

Review circulation formats where the facility design requires internal air movement. Confirm positioning, guarding and access separately from the outdoor-air exchange requirement.

Explore this fan family →
Select a model for this applicationLONGWELL Fan Selector — every model with its catalogue curve, datasheet and drawing. No login.
Or enter the duty point directly

Airflow and static pressure at the installed condition — the selector returns every model whose curve covers it, with margin, power and noise.

Library: Ø25–1,000 mm, single units up to about 52,000 m³/h — larger duties go straight to an engineer. Prefer to talk it through? Send your specs to an engineer

Product images show family configurations. Request the drawing, curve and electrical information for the exact model being considered.

03 / Prepare a useful selection brief

What should your fan enquiry include?

Share these application details so the fan proposal can be reviewed against your equipment.

01Livestock type, building layout and designer requirements
02Minimum and warm-weather ventilation operating points
03Intake, shutter, duct and guard arrangements
04Fan staging, controls and fault indication
05Dust, moisture, corrosion and cleaning exposure
06Mounting, power supply and maintenance access

Bring the equipment context to the fan review.

A drawing, the operating condition and a clear control requirement make the proposed configuration easier to compare. For a replacement, include the existing nameplate and wiring details.

Discuss your application →
04 / Technical resources

Reference material for the next step.

Catalogs support initial selection. Confirm the current specification and approved configuration with the project team.

Can maximum airflow determine the complete barn selection?

Maximum airflow does not describe minimum ventilation or the pressure needed by the intake arrangement. Review the seasonal schedule and installed resistance at the relevant stages. The building designer should confirm distribution and animal-environment requirements using the complete ventilation system.

How should an operating-cost comparison be prepared?

Compare measured or supported fan input power at equivalent airflow and pressure, then apply the expected hours in each operating state. Include the selected control strategy and installed equipment costs. A motor label or catalog maximum alone does not establish project savings.

From application to a concrete proposal

Share your equipment and operating conditions.

Send the drawing, target duty and project timing. Add the existing fan details when you need a replacement.

Send your requirements →