On April 14, 2026, LONGWELL opened an engineering project to evaluate and specify an industrial centrifugal fan assembly under model designation LW4-72-5.6A-002. The design focus was targeted at matching industrial ventilation duty requirements for dust filtration systems.

Backward-curved centrifugal fan with a metal impeller
Representative backward-curved centrifugal fan; project specifications are listed below.

Input technical requirements

The original application requirement called for an industrial centrifugal fan operating on three-phase 220V/380V power, powered by an 18.5 kW motor, with an IP55 protection target. Operating specifications requested an air volume of 15,000 m³/h at 250 mmH2O static pressure.

Engineered technical specifications

LONGWELL engineering developed the specification sheet version A0 for model LW4-72-5.6A-002, which was completed and technically reviewed on April 20, 2026. The established design parameters reflect the following electrical, mechanical, and aerodynamic performance parameters:

Parameter Value / Standard
Model Designation LW4-72-5.6A-002
Nominal Voltage & Frequency 3~380 VAC, 50 Hz
Motor Speed 2900 RPM
Motor Rating 18.5 kW (YE3 Motor)
Airflow Range 10,109 – 20,216 m³/h
Static Pressure Range 2,195 – 3,465 Pa
Protection & Insulation Rating IP 54, Class F
Operating Ambient Temperature -20 °C to +40 °C
Duty & Bearings S1 continuous, maintenance-free deep groove ball bearings

Applicable standard references incorporated into the engineering documentation include GB12350 for motor safety requirements, JB/T10563 for general purpose centrifugal fan specifications, and ISO5801-1997 for performance testing using standardized airways.

The requested protection target was IP55; the output sheet lists IP54. The airflow and pressure ranges are specification ranges and do not establish the requested duty point as a tested operating condition.

Drawing output and design handover

Engineering completed the standard specification layout and technical document review on April 20, 2026. The finalized model design LW4-72-5.6A-002 serves as the technical baseline for dimensional and electrical integration evaluations.

Drawing excerpt from the engineering file prepared for this request
Engineering drawing excerpt for the requested configuration.

Discuss a similar requirement

If your application requires custom industrial centrifugal fans or modified specifications within the LW4-72 series, submit your targeted operating point (airflow and static pressure), voltage supply, duty environment, and space limitations directly to our team through LONGWELL Contact or evaluate model capabilities on the LONGWELL Fan Selector.

Choose the right centrifugal fan

Longwell manufactures 947 centrifugal fans in-house. Send airflow, static pressure and voltage — an engineer replies with a matching model, performance curve and price within one working day.

Get A Quote

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Recent Articles

Categories

Archives