Table of Contents

LONGWELL offers two 80 × 80 × 25 mm DC fan candidates for SUNON MF8025 V1 replacements. Compare the LWAD8025LX-30 for the 12 V MF80251V1-1000U-A99 and the LWAD8025MX-32 for the 24 V MF80252V1-1000U-A99. These models have the same nominal frame size and similar catalogue airflow and pressure endpoints. Final approval depends on airflow at the required static pressure, the mounting drawing, the electrical interface and the test in your equipment.

80 × 80 × 25 mm model comparison

Published specificationSUNON MF80251V1-1000U-A99LONGWELL LWAD8025LX-30SUNON MF80252V1-1000U-A99LONGWELL LWAD8025MX-32
Rated supply12 VDC12 VDC24 VDC24 VDC
Nominal frame80 × 80 × 25 mm80 × 80 × 25 mm80 × 80 × 25 mm80 × 80 × 25 mm
Nominal mounting-hole centre spacing71.5 × 71.5 mm71.5 × 71.5 mm71.5 × 71.5 mm71.5 × 71.5 mm
Mounting-hole diameter in published drawingØ4.3 mm nominalØ4.4 mm nominalØ4.3 mm nominalØ4.4 mm nominal
Maximum airflow41.0 CFM41.2 CFM41.0 CFM41.2 CFM
Maximum static pressure≈44.8 Pa≈47.3 Pa≈44.8 Pa≈47.3 Pa
Rated current120 mA120 mA65 mA60 mA
Rated input1.44 W1.44 W1.56 W1.44 W
Rated speed3,200 rpm3,300 rpm3,200 rpm3,300 rpm
Published acoustic rating33.0 dB(A)37.5 dB(A)33.0 dB(A)37.5 dB(A)

Maximum airflow is the free-air endpoint. Maximum static pressure is the zero-airflow endpoint. For a fan behind a filter, grille or heatsink, compare the model curves at the static pressure and airflow your equipment needs. The acoustic ratings are published by each manufacturer. Confirm noise in the same setup before approving an acoustic requirement. SUNON 12 V specification · SUNON 24 V specification · SUNON DC fan catalogue · LONGWELL DC electronics cooling fan catalogue · LONGWELL LWAD8025MX-32

Check the fit, wiring and airflow before you order

  1. Confirm the full nameplate code and supply. The 12 V and 24 V versions share the nominal envelope. Check the actual supply range at start-up and during operation, along with your current limit.
  2. Compare the installation drawings. Check the screw and bracket clearance, frame thickness, air inlet and outlet, airflow direction and lead exit. Use the approval drawing for final dimensions and tolerances.
  3. Match the electrical interface. Share the connector drawing, polarity and pinout with the engineer. If your controller expects a tachometer, an alarm output or a separate PWM input, specify the exact signal and connector.
  4. Validate the system duty point. Approve the airflow and component temperatures with the final grille, filter and enclosure fitted. Check sound, current and restart behaviour in the same assembly.

For a related example of how bearing choice and wiring are documented, see the separate LONGWELL 8025 engineering case. 8025 DC axial fan development case

Frequently asked questions

Can LONGWELL provide a replacement candidate for SUNON MF8025 V1?

Yes. Evaluate LWAD8025LX-30 for MF80251V1-1000U-A99 at 12 VDC, or LWAD8025MX-32 for MF80252V1-1000U-A99 at 24 VDC. Confirm the operating point, voltage range, control or feedback, installation and application test before approval.

Is a 41 CFM rating enough to match the original fan?

Use 41 CFM as a free-air reference. For an enclosed assembly, ask for the airflow available at the pressure drop of your filter, guard and heatsink. Adding flow resistance changes the available airflow.

What should I send to specify a replacement?

Send a photo of the original nameplate, the mounting drawing or measured clearances, a photo of the connector, the supply voltage, the target airflow at static pressure and any noise or feedback requirements. Request an engineering review · Browse the fan cross-reference guide

SUNON model names identify the original fans in this comparison. Each manufacturer provides its own specifications and approvals.

Get A Quote

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.