LONGWELL can review the LWCC-DC300MB-01 as a replacement candidate for 26 VDC condenser and thermal-management assemblies using an ebm-papst W3G300-ME46-01 or W3G300-ME48-11. The candidate shares the published 16–32 VDC supply range. Before ordering, confirm the airflow and static pressure, electrical load, connector and mounting with the equipment supplier or an engineer. LONGWELL model specifications
Check the full W3G300 part number
The ME46-01 and ME48-11 are both 26 VDC brushless axial fans. The ME46-01 operating instructions list 3,000 rpm, 175 W and 6.7 A in free air. The ME48-11 preliminary manufacturer datasheet lists 3,650 rpm, 320 W and 12.4 A in free air. Check the current datasheet for your exact suffix. The readings at your installed operating point depend on the resistance of the coil, guard and ductwork. ME46-01 operating instructions · ME48-11 preliminary manufacturer datasheet
Compare the ME46-01 with the LONGWELL candidate
| Check | ebm-papst W3G300-ME46-01 | LONGWELL LWCC-DC300MB-01 |
|---|---|---|
| Supply | 26 VDC nominal, 16–32 VDC range | 26 VDC nominal, 16–32 VDC range |
| Nominal drawing depth | 76.7 mm from the 2022 dimension chain | 79.5 mm |
| Mounting | Four mounting points at 90° intervals, with orientation and tolerances shown on the drawing | Four mounting points on a 238.3 × 238.3 mm nominal pattern as drawn |
| Electrical interface | Four-pole connector with supply, ground, speed command and diagnostic output. The manufacturer lists 0–10 VDC or PWM speed control | Three-terminal wiring drawing. Confirm the command and diagnostic requirements against the supplied configuration |
| Published ingress protection | IP24 KM motor. IP6K9K electronics with the mating connector installed | IP68 as specified. Confirm sealing of the installed assembly |
Compare the mounting drawings on the same datum, including the position of the connector and wire exit. Allow space behind the fan for the cable and guard. If the controller expects a diagnostic signal, include that requirement in the review. Confirm the operating and start-up current against the power supply, harness and circuit protection before fitting a sample. ME46-01 dimensioned drawing and connection data · LWCC-DC300MB-01 dimensioned drawing and wiring
Check the housing revision on the unit in service. Share photos and dimensions of the guide ring, cable holder and wire exit, and use the original unit to confirm installed clearance.
Compare performance at the required airflow and static pressure
Record the airflow and static pressure across the installed fan at normal operation. Include the expected coil condition, air direction, supply voltage under load and the temperature range. Ask for a current fan curve for the exact candidate and test voltage. For continuous operation below −25°C, confirm bearing suitability and the cold-start requirements. The ME46-01 operating instructions specify special low-temperature bearings for continuous use below that threshold. ME46-01 operating instructions
Can LONGWELL review a W3G300 replacement?
Yes. Send the original model and nameplate photo, the required airflow and static pressure, the measured voltage range, a connector photo or pinout, and a mounting drawing. Include any required speed feedback, fault signal, or vehicle environmental and EMC requirements. LONGWELL can review the candidate and identify which checks to complete before an installation trial. Request an engineering review
For other W3G300 suffixes and fan families, see the W3G300 series reference and the LONGWELL cross-reference guide.