LONGWELL offers the LWCC-DC305MS-10 as an engineering candidate for SPAL VA10-BP70/LL-61A replacement. Both are nominal Ø305 mm, 24 VDC suction fans. At about 100 Pa static pressure, the SPAL suction table reports 1,850 m³/h at a 26 V test supply. The LONGWELL exact-model test sheet reports 1,913.7 m³/h at 100 Pa with a 24 V test supply. The next step is to verify the required airflow with your condenser and actual vehicle supply. SPAL manufacturer data sheet copy · LONGWELL automotive condenser fan catalogue, printed p. 18
How the fans compare as pressure increases
| SPAL static pressure / LONGWELL static pressure | SPAL VA10-BP70/LL-61A at 26 VDC | LONGWELL LWCC-DC305MS-10 at 24 VDC |
|---|---|---|
| 5 mmH₂O (about 49 Pa) / 50 Pa | 2,160 m³/h, 7.7 A | 2,311.0 m³/h, 8.1 A |
| 10 mmH₂O (about 98 Pa) / 100 Pa | 1,850 m³/h, 7.8 A | 1,913.7 m³/h, 8.3 A |
| 15 mmH₂O (about 147 Pa) / 150 Pa | 1,110 m³/h, 7.1 A | 1,536.8 m³/h, 8.5 A |
The SPAL values are from the -61A suction column. The LONGWELL values are from the 24 V test table on its model drawing dated July 24, 2023. The public LONGWELL catalogue separately lists 2,000 m³/h at 100 Pa as a selection reference. The table above reports operating-point measurements under each manufacturer’s own conditions. Request the current model-specific approval drawing and curve for the electrical supply, airflow and pressure you need. SPAL test table · LONGWELL catalogue and model index
Verify the shroud, wiring and vehicle supply
- Measure axial clearance and hole locations. The SPAL drawing includes an 87.5 ± 1 mm axial dimension and four Ø6.5 mm holes. The LONGWELL drawing shows 95 mm overall depth and separately labels four Ø7 mm and four Ø6.5 mm features. Confirm which mounting points your bracket uses. Check the shroud outline, blade clearance and cable exit against the approved drawing.
- Check the circuit where the fan runs. A nominal 24 V system can operate at a different voltage during starting and charging. Measure voltage at the fan, confirm startup and running current, and review connector, fuse, relay and harness requirements against the selected fan. The current in an airflow table applies to the listed point.
- Confirm suction and environmental requirements. SPAL lists -61A for suction and -61S for blowing. Match the direction at the condenser and check the exact connector, polarity, splash exposure, vibration and any approvals required by the equipment.
For a 12 V installation, compare the distinct VA10-AP70/LL-61A application and its own electrical and performance data. SPAL VA10 12 V suction fan replacement guide
Frequently asked questions
Can LONGWELL provide a candidate for the SPAL VA10-BP70/LL-61A?
Yes. Evaluate LWCC-DC305MS-10 for a nominal Ø305 mm, 24 V suction condenser application. Confirm airflow with the coil and shroud installed, the voltage at the fan, wiring and mounting geometry before project approval.
Which data should I send for an engineering review?
Send the full part number and nameplate, the condenser or vehicle application, target airflow and static pressure, nominal and measured supply voltage, connector photos, and the mounting pattern with available depth. Request an engineering review · Browse the fan cross-reference guide
SPAL model names identify the original equipment used for this comparison.