LONGWELL offers the LWCC-DC305LS-09 as a replacement candidate for the SPAL VA10-AP70/LL-61A in 12 V condenser applications. Both are nominal 305 mm suction axial fans. At roughly 100 Pa static pressure, SPAL publishes 1,570 m³/h at a 13 V test voltage, while LONGWELL lists 2,000 m³/h at 100 Pa for its 12 V model. Use these data to decide whether to evaluate the candidate, then confirm the required airflow and electrical load with the actual condenser and wiring.
Published specifications for the 305 mm suction fans
| Selection parameter | SPAL VA10-AP70/LL-61A | LONGWELL LWCC-DC305LS-09 |
|---|---|---|
| Nominal supply | 12 VDC | 12 VDC |
| Nominal fan diameter | 305 mm (12 in) | 305 mm |
| Airflow direction | Suction | Suction |
| Published airflow near 100 Pa | 1,570 m³/h at 10 mmH₂O (about 98 Pa), tested at 13 VDC | 2,000 m³/h at 100 Pa, listed for the 12 V model |
| Published current | 13.7 A at the SPAL operating point above | ≤18 A in the LONGWELL model table |
| Mounting holes shown | 4 × Ø6.5 mm | 4 × Ø6 mm |
| Installation drawing | SPAL dimensioned drawing and test table | LONGWELL catalogue, printed p. 18 |
The SPAL catalogue lists separate suction and blowing models. Use the -61A column for this comparison and check the complete suffix on the original nameplate. The installation drawings show different mounting details. Compare the complete shroud, hole pattern, depth, cable exit and connector before ordering. SPAL dimensioned drawing and test data · LONGWELL condenser fan catalogue, printed p. 18 · LONGWELL catalogue and model index
Check the condenser airflow and the 12 V circuit
Use the pressure drop of your condenser. Compare airflow at the restriction created by the coil, guard and shroud. The published points are close in static pressure and use different voltage references. The LONGWELL catalogue entry gives one duty point. Ask for the curve for the proposed sample and validate the working point at the vehicle’s actual supply voltage.
Check running and starting current. SPAL’s 13.7 A is the measured value at one published duty point. LONGWELL lists catalogue current at ≤18 A for its model. Check supply voltage, startup current, connector and terminal ratings, relay, fuse and wiring capacity against the proposed configuration.
Overlay the drawings before sampling. Match the suction arrangement, airflow arrows, shroud footprint, mounting holes, axial and blade clearance, and connector polarity. If the application specifies water and dust protection, vibration or vehicle electrical testing, confirm those requirements for the exact configuration and assembly.
Frequently asked questions
Can LONGWELL provide a replacement candidate for SPAL VA10-AP70/LL-61A?
Yes. Evaluate the LWCC-DC305LS-09 for a nominal 305 mm, 12 V suction application. Confirm the measured airflow at the required static pressure, the mounting and wiring, and the electrical and environmental requirements as part of the approval.
Can I use the original connector and mount?
Compare the approval drawings and connector pinout before reusing either. Send the original connector photos and key dimensions with your enquiry so the proposed configuration and any mounting changes can be checked together.
What should I send for a replacement quote?
Send the complete part number and nameplate photo, available mounting dimensions, required airflow at static pressure, connector details, operating voltage range and current limit. Include the condenser model and airflow direction. Request an engineering review · Browse the fan cross-reference guide
SPAL model names identify the original equipment in this comparison.
For a 24 V system, see the factory model and circuit comparison in the SPAL VA10-BP70/LL-61A 24 V replacement guide.