NMB lists the 3110KL-04W-B60-B00 as discontinued and recommends the 08025SA-12N-AA-D0 as its successor. For equipment that uses the original 80 × 80 × 25 mm frame and a 12 VDC supply, LONGWELL offers the LWAD8025LX-29-00 as an additional candidate for engineering review. Check the minimum supply voltage first. NMB specifies operation from 6 V for both of its models, while the LONGWELL A0 specification lists an operating range beginning at 7 V. NMB discontinued fan and successor listing · LONGWELL LWAD8025LX-29 specification case
Compare the original fan, the NMB successor and the LONGWELL candidate
| Published specification | NMB 3110KL-04W-B60-B00 | NMB 08025SA-12N-AA-D0 | LONGWELL LWAD8025LX-29-00 |
|---|---|---|---|
| Nominal frame | 80 × 80 × 25 mm | 80 × 80 × 25 mm | 80 × 80 × 25 mm |
| Rated supply | 12 VDC | 12 VDC | 12 VDC |
| Published operating range | 6–13 VDC | 6–13.8 VDC | 7–13.8 VDC |
| Rated or listed current | 0.26 A | 0.14 A | 0.26 A |
| Listed input power | 3.1 W | 1.7 W | 3.12 W |
| Rated speed | 3,400 rpm | 3,100 rpm | 3,600 rpm |
| Maximum airflow | 40.2 CFM | 41.3 CFM | 42.02 CFM |
| Maximum static pressure | 40.2 Pa | 37.5 Pa | About 54.0 Pa |
| Type of bearing | Ball bearing | Ball bearing | Two ball bearings |
| Published acoustic reading | 35 dB | 30 dB | 38 dB(A) |
Maximum airflow is the free-air endpoint. Maximum static pressure is the zero-flow endpoint. Because the three airflow figures are close, the better way to select a fan behind a grille, filter or heatsink is to compare airflow at the pressure your enclosure actually needs. The listed acoustic values come from the individual manufacturers. Compare them in the same setup if your equipment has a noise limit. NMB legacy model datasheet · NMB successor datasheet · LONGWELL A0 specification, P–Q curve and drawing, pp. 2–5
Three checks for the original equipment
Start-up and timing. Measure the voltage at the fan connector during power-up and at the lowest equipment supply. The LONGWELL A0 specification lists a soft-start interval of less than 10 seconds to reach full speed. Where the system needs airflow immediately or uses a timed fault check, validate the actual time to airflow and the restart behavior.
Mounting and wiring. The LONGWELL A0 drawing shows 71.5 ± 0.3 mm square hole spacing, Ø4.3 ± 0.3 mm holes and 300 ± 10 mm leads. Overlay the original part against the drawing to check screw fit, frame clearance, airflow direction and lead exit. Verify the connector and polarity, and identify any separate monitoring requirement before ordering an exact configuration.
Cooling under load. Check the fan with the filter, grille and other internal parts in place. If the equipment runs at several speeds or temperatures, test the airflow, component temperatures and noise at the settings that matter to the installation.
Frequently asked questions
What replacement does NMB list for 3110KL-04W-B60-B00?
NMB lists 08025SA-12N-AA-D0. Its own datasheet lists 0.14 A rated current and 41.3 CFM maximum airflow. Confirm the successor against the application’s pressure requirement and installation dimensions. NMB successor model
Can LONGWELL provide a replacement candidate?
Yes. Evaluate LWAD8025LX-29-00 for an 80 × 80 × 25 mm, 12 VDC ball-bearing application. Final selection depends on airflow at your static pressure, operating and starting voltage, mounting, wiring and project testing.
Send the full model and nameplate, a wiring or connector photo, the lowest supply voltage at startup, and the required airflow and static pressure. Request an engineering review · Browse the fan cross-reference guide
NMB model names identify the original equipment and the NMB-listed successor in this comparison.