Table of Contents

LONGWELL can review the LWDA-150(6″)S-PBN-002S as a two-speed AC candidate for installations using a Blauberg Turbo 150. The two models serve nominal 150 mm ducts and use different spigot dimensions and supply specifications. Check the installation, power supply and both duty points before choosing a replacement. Blauberg Turbo data sheet · LONGWELL LWDA-150(6″)S-PBN-002S specification

Compare the supply and installation drawings

CheckBlauberg Turbo 150LONGWELL LWDA-150(6″)S-PBN-002S
Supply in the published data230 VAC, single-phase, 50/60 Hz220 VAC, 50 Hz
Speed controlTwo-speed AC motor. Check the label for the switch, timer or controller variantHigh- and low-speed connections shown in the wiring drawing
Spigot outside diameter shown on the drawing148 mm144 mm
End-to-end length289 mm320 mm

Allow for the additional 31 mm of length and check that the duct connector can seal on the smaller spigot. Compare the mounting bracket and service clearance. Check the existing control against the candidate's wiring diagram. For a 230 VAC or 60 Hz system, ask LONGWELL to confirm the supply rating of the exact configuration before ordering. Blauberg dimensions and speed options · LONGWELL dimensions and wiring

Compare airflow at the same static pressure

The figures below are approximate readings from the manufacturers' published curves, rounded to the nearest 10 m³/h. The Blauberg catalogue shows one curve for each speed. The LONGWELL data sheet shows one curve without a speed label. Use this table to screen options and request both curves for the proposed supply and control configuration before assigning operating points.

Static pressureTurbo 150 low speedTurbo 150 high speedLONGWELL published curve
100 Pa280 m³/h480 m³/h490 m³/h
150 Pa130 m³/h370 m³/h440 m³/h

For a shorter installation that has a 50 Hz supply, the LWDA-150 (6″)S-MWN-02 is another 150 mm option. Its drawing shows a 204 mm length. Ask for its duty curve and speed-control options if the original low and high settings are required. LWDA-150 (6″)S-MWN-02 and dimensional drawing

Request a replacement review

Send a photo of the full Turbo 150 label, your line voltage and frequency, the required airflow and static pressure, the control type, and the space available between duct connections. If you use both speeds, include the required airflow at each setting. Request an engineering review

Get A Quote

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.