LONGWELL can review two 120 × 120 × 38 mm AC fan candidates for Mechatronics UF12A equipment. Use LWAA12038UH-28-00 to assess the lead-wire UF12A12-BWH in a 115 VAC application. Use LWAA12038SH-36-00 as an engineering candidate for the 230 VAC terminal model UF12A23-BTH, subject to supply, current and connection review. Confirm the full nameplate, the enclosure airflow at static pressure and the available circuit capacity before ordering. Mechatronics model series · Official part-number key
Check the 115 VAC lead-wire configuration
| Check | Mechatronics UF12A12-BWH | LONGWELL LWAA12038UH-28-00 engineering sample |
|---|---|---|
| Original supply and connection | 115 VAC, 50/60 Hz, ball bearing, high-speed grade, wire leads | Ball bearing, wire leads. Approve the exact ratings, lead length, termination and bonding for the equipment’s 115 VAC supply |
| Nominal mounting geometry | 120 × 120 × 38 mm, 104.8 × 104.8 mm hole pitch | 120 × 120 × 38 mm, 105 × 105 mm hole pitch |
| Free-air airflow, 50/60 Hz | 92/106 CFM | 93/98 CFM |
| Static pressure at zero airflow, 50/60 Hz | 8.13/8.13 mm H₂O, current manufacturer listing | 7.0/8.5 mm H₂O |
| Airflow near 25 Pa, 60 Hz chart comparison | About 90 CFM from the earlier published H-grade curve | About 65 CFM from the engineering sample curve |
At 60 Hz, the chart comparison shows a larger airflow difference under resistance than the free-air ratings suggest. The earlier Mechatronics H-grade chart uses a different shutoff pressure from the current product listing. Compare current curves for the exact supply and check the actual cabinet airflow and component temperatures with the filter and guard in place. The current Mechatronics listing gives 0.20/0.16 A at 50/60 Hz. Confirm the candidate’s approval voltage, starting and running current and power against the equipment’s circuit requirements. Mechatronics 115 VAC H-grade data · Mechatronics dimensions and earlier curves
Check the 230 VAC terminal configuration
| Check | Mechatronics UF12A23-BTH | LONGWELL LWAA12038SH-36-00 engineering sample |
|---|---|---|
| Rated supply | 230 VAC, 50/60 Hz | Sample specification 220 VAC, 50/60 Hz. Approve the intended 230 VAC range before ordering |
| Connection | Ball bearing, high-speed grade, 0.110-inch terminal option | Ball bearing. Drawing specifies 300 ±10 mm leads and also shows tab geometry. Confirm the supplied termination and the mating harness |
| Mounting-hole pitch | 104.8 × 104.8 mm, ±0.3 mm | 105 × 105 mm, ±0.5 mm |
| Rated or sample current, 50/60 Hz | 0.10/0.08 A | 0.15/0.18 A on the 220 VAC sample specification |
| Input power, 50/60 Hz | 17/15 W | 25/26 W on the 220 VAC sample specification |
| Free-air airflow, 50/60 Hz | 92/106 CFM | 99/112 CFM |
| Airflow near 25 Pa, 60 Hz chart comparison | About 90 CFM from the earlier published H-grade curve | About 75 CFM from the engineering sample curve |
The terminal version requires particular attention to the electrical load and the physical connection. Check the connector and its clearances, terminal retention, frame bonding, wire ratings, protective devices and startup under the intended supply. An enclosure that needs the original curve or circuit load should be assessed with the relevant mounting, supply, airflow and thermal limits in the approval drawing. The LONGWELL catalogue lists base codes. Use the approved data for the exact order suffix. Mechatronics 230 VAC H-grade data · LONGWELL AC cooling fan catalogue, PDF page 9
Request a replacement review
Send the full fan nameplate, actual voltage and frequency, the required airflow at static pressure, photos of the wire leads or connector, mounting dimensions and any current, temperature or approval limits. Ask for an approval drawing and a sample matched to the complete order suffix. Contact LONGWELL engineering · View the fan cross-reference guide