LONGWELL LWAD8025LX-28-00 is a replacement candidate for the two-wire Delta AFB0812HH in 12 V equipment. Both specification sheets list 0.20 A, 3,250 rpm, 37.43 CFM at zero static pressure and 4.59 mmH₂O at zero airflow. Before approving a sample, check the bracket, connector and airflow through the assembled equipment. Delta AFB0812HH approval specification · LONGWELL LWAD8025LX-28-00 engineering data
80 mm fan specifications
| Parameter | Delta AFB0812HH | LONGWELL LWAD8025LX-28-00 |
|---|---|---|
| Rated voltage and operating range | 12 VDC, 7.0–13.8 VDC | 12 VDC, 7.0–13.8 VDC |
| Rated input | 0.20 A / 2.40 W | 0.20 A / 2.40 W |
| Reference or nominal speed | 3,250 rpm | 3,250 rpm |
| Maximum free-air flow | 37.43 CFM | 37.43 CFM |
| Maximum static pressure at zero airflow | 45.0 Pa (4.59 mmH₂O) | 45.0 Pa (4.59 mmH₂O) |
| Nominal frame | 80 × 80 × 25.4 mm | 80 × 80 × 25 mm |
| Square mounting pitch | 71.5 mm | 71.5 mm |
| Lead configuration | Two power leads | Two power leads |
What to verify in the enclosure
- Bracket fit and polarity. The nominal depths differ by 0.4 mm. Check the screw and spacer stack, cable exit, grille and airflow direction. Confirm the mating connector pinout and polarity before powering the sample.
- Airflow through the equipment. The reported maximum airflow and pressure describe opposite ends of each curve. A filter, heat sink or grille adds resistance. Use the Delta 12 V curve and the curve for the current LONGWELL sample to check airflow at the required pressure. Verify the temperature of the critical components at normal load. Delta performance curve and dimensions p.5–6
- Controls and environment. This comparison covers the plain two-wire AFB0812HH. For a unit labeled
AFB0812HH-F00, send the full part number and original connector so engineering can check the tachometer requirement separately. Confirm the ambient temperature, startup limits and any monitoring the equipment uses. Delta AFB0812HH-F00 product data
Send the fan label, mounting drawing, connector photo, supply limits and target airflow at static pressure for a sample review. Request an engineering review · Fan replacement guide