LONGWELL can evaluate LWAA12038SH-36-00 as a 120 × 38 mm ball-bearing AC fan candidate for equipment using ADDA AA1282HB-AT (A1CF). Start with the original nameplate and terminals, then verify airflow under cabinet resistance, actual line voltage and the running current of the proposed configuration. ADDA A1CF manufacturer specification and curves

Compare the electrical, mounting and airflow data

CheckADDA AA1282HB-AT (A1CF)LONGWELL LWAA12038SH-36-00 engineering sample
Rated supply230 VAC, operating range 220–240 VAC, 50/60 Hz220 VAC, 50/60 Hz on the sample specification. Confirm approval for the equipment’s 230 VAC supply
Nominal frame and bearing120 × 120 × 38 mm class, two ball bearings120 × 120 × 38 mm, ball bearing, 105 ±0.5 mm square pitch
ConnectionADDA CF family identifies -AT as terminal termination. Check the original housing, connector and bonding pointSample drawing describes 300 ±10 mm wire leads and shows tab geometry. Confirm the delivered termination, mating connector and bonding
Running current, 50/60 Hz0.13/0.11 A at the manufacturer’s rated conditions0.15/0.18 A per 220 VAC sample specification
Free-air airflow, 50/60 Hz91.2/103.5 CFM99/112 CFM
Static pressure at zero airflow, 50/60 Hz8.17/9.07 mm H₂O7.4/8.4 mm H₂O
Airflow near 25 Pa, 50/60 HzAbout 65/80 CFM from the ADDA 230 VAC test curvesAbout 55/75 CFM from the engineering sample curves

Use the curve at the equipment’s own voltage and frequency. The free-air airflow is higher on the LONGWELL sample sheet, while the approximate 25 Pa readings are lower. Check the actual filter and grille resistance and confirm component temperatures. ADDA separately lists measured and rated power. Use the approved data for the actual supply and configuration when sizing protection or assessing heat load. ADDA A1CF electrical data, PDF p. 2 · ADDA A1CF 230 VAC curves, PDF p. 7

Approve the connector and mounting before sampling

Confirm the original connector and frame bonding arrangement, wire clearance, mounting pattern, fasteners and airflow direction. Where the original connector or grounding point must be retained, include it in the requested approval drawing. Verify startup and running current on the actual circuit, including protective devices, before approving the candidate. The LONGWELL catalogue lists base model codes. Use the exact order suffix on the approved drawing. LONGWELL AC fan catalogue, PDF p. 9

Request an engineering review

Send the complete label and any A1CF marking, supply voltage and frequency, the target airflow at static pressure, installation dimensions and photos of the electrical terminals and frame bonding point. Include the current and temperature limits of the equipment. Contact LONGWELL engineering · View the fan cross-reference guide