Table of Contents

Engineering Modification for 380V System Compatibility

On April 14, 2026, LONGWELL opened a technical project to convert a 450mm EC axial fan into a blowing configuration operating on a 3~380 VAC three-phase power supply. Based on the baseline model LWAE3G450SS-5MEW-03-00, LONGWELL engineering assigned part number LWAE3G450TT-5PEW-16-00 and prepared the revised technical drawing and specification on April 20, 2026.

Axial fan with a circular wire guard and metal blades
Representative guarded axial fan; project specifications are listed below.

Base Design vs. Target Specification Parameters

The engineering team evaluated the reference design specification for LWAE3G450SS-5MEW-03-00 and generated the target specification drawing for LWAE3G450TT-5PEW-16-00. Key engineering values specified across the two designs include:

Technical Parameter Base Design (LWAE3G450SS-5MEW-03-00) Output Specification (LWAE3G450TT-5PEW-16-00)
Nominal Voltage 230 VAC (1-phase) 3~380 VAC (3-phase)
Voltage Range 176–264 VAC 304–456 VAC
Nominal Speed 1590 rpm 1950 ± 5% rpm
Power Input 420 W 900 W
Current 2.0 A 1.4 A
Impeller Material Cold-rolled sheet PA66+GF
Insulation / Protection Class B / IP54 Class F / IP20
Maximum Air Flow 6695 m³/h (3985 CFM) 8343 m³/h (4908 CFM)
Maximum Static Pressure 242 Pa 345 Pa

To view the full technical drawing documentation, refer to the LWAE3G450TT-5PEW-16-00 Specification Sheet and the LWAE3G450SS-5MEW-03-00 Reference Sheet.

Scope of Delivery

This project scope covers the evaluation of the blowing configuration and 380V electrical system requirements, resulting in the completed engineering specification and technical drawing output for customer model fit assessment.

Drawing excerpt from the engineering file prepared for this request
Engineering drawing excerpt for the requested configuration.

Request Specifications for Similar Fan Projects

If your application requires customized voltage inputs, blowing or sucking airflow directions, or specific motor ratings for EC axial fans, submit your parameters to our engineering team. Contact us through our contact page or explore fan options at the LONGWELL Fan Selector.

Choose the right ec axial fan

Longwell manufactures 152 ec axial fans in-house. Send airflow, static pressure and voltage — an engineer replies with a matching model, performance curve and price within one working day.

Get A Quote

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Recent Articles

Categories

Archives