Engineering Modification for 380V System Compatibility
On April 14, 2026, LONGWELL opened a technical project to convert a 450mm EC axial fan into a blowing configuration operating on a 3~380 VAC three-phase power supply. Based on the baseline model LWAE3G450SS-5MEW-03-00, LONGWELL engineering assigned part number LWAE3G450TT-5PEW-16-00 and prepared the revised technical drawing and specification on April 20, 2026.

Base Design vs. Target Specification Parameters
The engineering team evaluated the reference design specification for LWAE3G450SS-5MEW-03-00 and generated the target specification drawing for LWAE3G450TT-5PEW-16-00. Key engineering values specified across the two designs include:
| Technical Parameter | Base Design (LWAE3G450SS-5MEW-03-00) | Output Specification (LWAE3G450TT-5PEW-16-00) |
|---|---|---|
| Nominal Voltage | 230 VAC (1-phase) | 3~380 VAC (3-phase) |
| Voltage Range | 176–264 VAC | 304–456 VAC |
| Nominal Speed | 1590 rpm | 1950 ± 5% rpm |
| Power Input | 420 W | 900 W |
| Current | 2.0 A | 1.4 A |
| Impeller Material | Cold-rolled sheet | PA66+GF |
| Insulation / Protection | Class B / IP54 | Class F / IP20 |
| Maximum Air Flow | 6695 m³/h (3985 CFM) | 8343 m³/h (4908 CFM) |
| Maximum Static Pressure | 242 Pa | 345 Pa |
To view the full technical drawing documentation, refer to the LWAE3G450TT-5PEW-16-00 Specification Sheet and the LWAE3G450SS-5MEW-03-00 Reference Sheet.
Scope of Delivery
This project scope covers the evaluation of the blowing configuration and 380V electrical system requirements, resulting in the completed engineering specification and technical drawing output for customer model fit assessment.