Table of Contents

The LONGWELL LWAD12038HD-08 is a 48 V airflow and mounting candidate for equipment using the San Ace 120 9RA1248G10011. Both fans use a nominal 120 × 120 × 38 mm frame and deliver about 140 CFM in free air. If the equipment monitors fan speed, specify and verify a compatible tachometer output before approving the replacement. The Sanyo Denki model has a pulse sensor, and LWAD12038HD-08’s public data covers its mechanical and airflow ratings. Sanyo Denki exact model · LONGWELL LWAD12038HD-08 data and drawing

48 V fan comparison

ParameterSanyo Denki 9RA1248G10011LONGWELL LWAD12038HD-08
Nominal frame120 × 120 × 38 mm, ribless120 × 120 × 38 mm
Rated and operating voltage48 VDC, 40.8–55.2 VDC operating48 VDC rated, verify the operating range for the sample
Rated current and power0.18 A, 8.6 W0.20 A, 9.6 W
Rated speed4,200 rpm4,000 rpm
Maximum airflow at zero static pressure141 CFM238.2 m³/h, about 140 CFM
Maximum static pressure at zero airflow135 Pa127 Pa
Published noise46 dBA SPL55.2 dBA
Feedback and speed controlPulse tachometer output, no PWM speed inputRequest the exact harness and tachometer specification for approval

Check the tachometer before connecting it

Sanyo Denki identifies this part as a pulse-sensor model. Its San Ace DC sensor guide illustrates a two-pulse-per-revolution open-collector tachometer that requires a pull-up on the signal circuit. The guide gives typical circuit limits and directs users to confirm model-level details. Before wiring a replacement, verify the tachometer pin, controller ground, pull-up voltage, pulses per revolution, expected speed range and startup alarm delay. Use the host controller’s signal specification to determine the pull-up. The 48 V rating applies to motor power. Sanyo Denki DC fan sensor guide

When the verified configuration produces two pulses per revolution, 4,200 rpm corresponds to 140 Hz and 4,000 rpm corresponds to about 133 Hz. Check any low-speed alarm threshold against the actual sample reading at startup and under load. Sanyo Denki DC fan sensor guide

Verify the installed airflow and fit

Sanyo Denki’s catalog shows the G-speed family curves at 40.8, 48 and 55.2 V. Use the curve at the relevant supply voltage and compare the airflow available against the resistance of the equipment’s filter, grille and heat sink. The published sound levels come from separate sources. Measure temperatures and noise in the closed enclosure at normal load. Sanyo Denki San Ace 120 G-speed curves

The LONGWELL drawing shows a 105.0 ± 0.3 mm square mounting pitch and Ø4.5 mm holes. Review the original ribless frame drawing and check the screw stack, gasket, grille and airflow direction. LONGWELL product drawing

Send a photo of the original label and connector, the operating voltage range, required airflow and static pressure, and the host controller’s tachometer input requirements. LONGWELL can review the duty point and the appropriate sample configuration. Request a technical review · Fan replacement guide