The LONGWELL LWAD12038HD-08 is a 48 V airflow and mounting candidate for equipment using the San Ace 120 9RA1248G10011. Both fans use a nominal 120 × 120 × 38 mm frame and deliver about 140 CFM in free air. If the equipment monitors fan speed, specify and verify a compatible tachometer output before approving the replacement. The Sanyo Denki model has a pulse sensor, and LWAD12038HD-08’s public data covers its mechanical and airflow ratings. Sanyo Denki exact model · LONGWELL LWAD12038HD-08 data and drawing
48 V fan comparison
| Parameter | Sanyo Denki 9RA1248G10011 | LONGWELL LWAD12038HD-08 |
|---|---|---|
| Nominal frame | 120 × 120 × 38 mm, ribless | 120 × 120 × 38 mm |
| Rated and operating voltage | 48 VDC, 40.8–55.2 VDC operating | 48 VDC rated, verify the operating range for the sample |
| Rated current and power | 0.18 A, 8.6 W | 0.20 A, 9.6 W |
| Rated speed | 4,200 rpm | 4,000 rpm |
| Maximum airflow at zero static pressure | 141 CFM | 238.2 m³/h, about 140 CFM |
| Maximum static pressure at zero airflow | 135 Pa | 127 Pa |
| Published noise | 46 dBA SPL | 55.2 dBA |
| Feedback and speed control | Pulse tachometer output, no PWM speed input | Request the exact harness and tachometer specification for approval |
Check the tachometer before connecting it
Sanyo Denki identifies this part as a pulse-sensor model. Its San Ace DC sensor guide illustrates a two-pulse-per-revolution open-collector tachometer that requires a pull-up on the signal circuit. The guide gives typical circuit limits and directs users to confirm model-level details. Before wiring a replacement, verify the tachometer pin, controller ground, pull-up voltage, pulses per revolution, expected speed range and startup alarm delay. Use the host controller’s signal specification to determine the pull-up. The 48 V rating applies to motor power. Sanyo Denki DC fan sensor guide
When the verified configuration produces two pulses per revolution, 4,200 rpm corresponds to 140 Hz and 4,000 rpm corresponds to about 133 Hz. Check any low-speed alarm threshold against the actual sample reading at startup and under load. Sanyo Denki DC fan sensor guide
Verify the installed airflow and fit
Sanyo Denki’s catalog shows the G-speed family curves at 40.8, 48 and 55.2 V. Use the curve at the relevant supply voltage and compare the airflow available against the resistance of the equipment’s filter, grille and heat sink. The published sound levels come from separate sources. Measure temperatures and noise in the closed enclosure at normal load. Sanyo Denki San Ace 120 G-speed curves
The LONGWELL drawing shows a 105.0 ± 0.3 mm square mounting pitch and Ø4.5 mm holes. Review the original ribless frame drawing and check the screw stack, gasket, grille and airflow direction. LONGWELL product drawing
Send a photo of the original label and connector, the operating voltage range, required airflow and static pressure, and the host controller’s tachometer input requirements. LONGWELL can review the duty point and the appropriate sample configuration. Request a technical review · Fan replacement guide