LONGWELL LWAD12038LM-26-11 is a replacement candidate for equipment using the two-wire NMB 4715KL-04W-B20-E00. NMB lists 11938KA-12K-EA-00 as its new part number. The NMB and LONGWELL fans both run on 12 VDC, draw a rated 0.40 A and use a 105 mm square mounting pitch. Check enclosure clearance, airflow under load and minimum supply voltage before approving a sample. NMB legacy part · NMB current part

12 V fan specifications

ParameterNMB 4715KL-04W-B20-E00 / 11938KA-12K-EA-00LONGWELL LWAD12038LM-26-11
Rated voltage12 VDC12 VDC
Operating voltage6.0–13.8 VDC7.0–13.8 VDC
Rated current and input0.40 A / 4.8 W0.40 A / 4.8 W
Rated speed2,650 rpm2,300 rpm
Maximum free-air flow97 CFM95 CFM
Maximum static pressure at zero flow55.9 Pa58.8 Pa (6.0 mmH₂O)
Frame dimensions on drawing119 × 119 × 38.4 mm120 × 120 × 38 mm
Square mounting pitch and holes105 ± 0.5 mm / Ø4.3 mm105 ± 0.3 mm / Ø4.2 mm
LeadsTwo power leadsTwo power leads, red positive and black negative

The NMB product pages list a nominal depth of 38 mm. Use the dimensions and tolerances shown in the drawings to check the actual assembly. The LONGWELL catalogue lists the LWAD12038LM-26 base model. Ask for the drawing and performance curve for the -11 configuration when reviewing the sample. NMB 11938KA dimension drawing · LONGWELL DC Electronics Cooling Fan catalogue

What to check on the equipment

  1. Measure the mounting pocket. Both drawings use a 105 mm pitch. Check the extra 1 mm of nominal frame width, the fasteners, the guard and the airflow direction. A square recess or seal can limit fit even when the holes line up.
  2. Measure airflow with the enclosure assembled. The 97 and 95 CFM figures are for zero static pressure. A filter, mesh guard or heat sink changes the operating point. Send the required airflow and static pressure and check enclosure temperature under the original load.
  3. Check the supply and leads during start-up. The LONGWELL configuration specifies a 7.0 V minimum operating voltage. Confirm that the supply stays within range and verify connector polarity. For a fan with an alarm or speed signal, send its full suffix and wiring diagram for a separate match.

Share a photo of the fan label, the mounting dimensions, the connector and the airflow required at the equipment’s static pressure. LONGWELL can review the application and confirm the relevant sample configuration. Contact LONGWELL · Fan replacement guide