For equipment using SUNON PMD1212PMB1-A (2).GN, LONGWELL LWAD12038LH-02 offers a 12 V, 4,200 rpm candidate with the same nominal footprint, frame depth and square mounting pitch. Compare the exact suffix and the system duty before choosing a sample.
Nominal specification comparison
| Specification | SUNON PMD1212PMB1-A (2).GN | LONGWELL LWAD12038LH-02 |
|---|---|---|
| Supply and nominal speed | 12 VDC / 4,200 rpm | 12 VDC / 4,200 rpm |
| Frame and square pitch | 120 × 120 × 38 mm / 105 mm | 120 × 120 × 38 mm / 105 mm |
| Mounting-hole diameter | Ø4.3 ± 0.3 mm | Ø4.5 mm |
| Rated current and input | 1.60 A / 19.2 W | 1.50 A / 18 W |
| Free-air flow | 190 CFM | 195.3 CFM |
| Shutoff static pressure | 161.9 Pa | 181 Pa |
| Nominal sound pressure | 54.0 dBA | 55.7 dBA |
SUNON figures are for the standard (2).GN entry in its DC catalog. LONGWELL ratings are from its model page. The zero-pressure and zero-airflow numbers describe separate endpoints. For electronics cooled through a heatsink or filter, ask for the current product curve at the intended voltage and compare airflow at the actual system resistance.
Check the full SUNON suffix and the enclosure fit
The catalog lists (2).R.GN and (2).F.GN as distinct signal configurations. If the host relies on tachometer feedback or an alarm, confirm the connector and signal definitions for the delivered variant. The bolt pattern has the same nominal pitch, with different mounting-hole diameters. Check fasteners, grille clearance, lead exit and airflow direction.
What to send for a replacement sample
Send the old nameplate, connector pinout, acceptable startup and running current, desired airflow at static pressure, and sound limit. On the first unit, validate equipment temperature and airflow at typical load and at the worst filter condition.
Review SUNON 80 × 25 mm options · Browse fan cross-references