For a cabinet fitted with an Orion OA109AP-11-1WB, LONGWELL can evaluate the lead-wire LWAA12038UH-28-00 as a 120 × 38 mm class ball-bearing fan candidate. Confirm the supplied configuration for your 115 VAC line, wiring and installed airflow before ordering. If the original nameplate reads OA109AP-11-1TB, review the terminal and grounding requirements below with the existing cord in hand. Orion OA109AP series and model numbers
Compare the wire-lead model and the LONGWELL candidate
| Check | Orion OA109AP-11-1WB | LONGWELL LWAA12038UH-28-00 |
|---|---|---|
| Enclosure fit | 119.5 × 119.5 × 38.5 mm, nominal | 120 × 120 × 38 mm, nominal |
| Mounting | 105 × 105 mm pitch, ±0.7 mm. Eight Ø4.2 ±0.3 mm holes | 105 × 105 mm pitch, ±0.5 mm. Confirm mounting-hole and fastener fit against the approval drawing |
| Bearing and termination | Ball bearings, two 22 AWG leads, 300 mm | Ball bearings and wire leads. Confirm lead length, termination and frame bonding in the supplied configuration |
| Supply and power | 115 VAC rated, 100–125 VAC, 50/60 Hz. 17/15 W at 50/60 Hz | Ask for the 115 VAC approval sheet for the exact order suffix, with voltage range, 50/60 Hz rating, running current and power |
| Free-air airflow at 50/60 Hz | 89/104 CFM | 93/98 CFM on the engineering sample specification |
| Shutoff static pressure at 50/60 Hz | 0.28/0.29 in. H₂O, about 70/72 Pa | 7.0/8.5 mm H₂O, about 69/83 Pa, on the engineering sample specification |
| Airflow near 25 Pa at 50/60 Hz | About 40/65 CFM, read from the high-speed curves | About 45/65 CFM, read from the engineering sample curves |
The airflow and pressure endpoints occur at different points on a fan curve. The approximate readings at 25 Pa help screen candidates. Check the pressure drop across the installed guard, filter and heat sink, then test airflow and temperature with the equipment powered at its actual line voltage and frequency. The LONGWELL catalogue lists the base code LWAA12038UH-28. Use the approval sheet for the specific order suffix to confirm electrical ratings and the supplied lead assembly. Orion drawings and 50/60 Hz curves · LONGWELL AC cooling fan catalogue, PDF page 9
If the original fan is OA109AP-11-1TB
The OA109AP-11-1TB is the ball-bearing terminal version. Orion shows two flat terminals about 0.5 mm thick and 3 mm wide on 8 mm centers. Its drawing identifies frame grounding holes marked M4 × 0.7 and #8-32. Check the connector body, terminal orientation, cord exit clearance and earth connection on the actual assembly. The LONGWELL candidate above is the lead-wire version. A project that must retain the existing terminal cord needs a separately approved terminal and grounding drawing for the proposed fan before an order is placed. Orion terminal and grounding detail · Orion fan cord and accessory reference
What should I send for an engineering review?
Send a photo of the full nameplate, the supply voltage and frequency, the required airflow and static pressure, and photos of the fan connector and frame bonding point. Include mounting dimensions, the ambient temperature range, and any cabinet noise limit or electrical approval requirement. LONGWELL can review the exact configuration with your drawings and application requirements. Request an engineering review · Browse the fan replacement guide