Plastic cross flow impeller engineering specification
On March 27, 2026, LONGWELL opened an engineering project to generate a standard drawing for a plastic cross flow fan impeller. The baseline customer specifications requested a length of 60 cm, a diameter of 90 mm, a steel shaft diameter of 6 mm, and an 8 mm sleeve bore, standardized on LONGWELL’s 90.5 mm outer diameter design platform.

LONGWELL engineering designated model number LWPI-φ90.5*600-05 and completed the technical specification drawing on March 27, 2026.
Documented engineering features
The engineering drawing for model LWPI-φ90.5*600-05 defines physical dimensions, mounting hardware, material properties, and operational parameters for the cross flow impeller assembly.
| Parameter | Value / Requirement |
|---|---|
| Model Number | LWPI-φ90.5*600-05 |
| Impeller Outer Diameter | Φ90.5 mm |
| Impeller Length | 600 ± 2 mm |
| Steel Shaft Diameter (End A) | Φ6 (+0 / -0.01) mm |
| Steel Shaft Extension (End A) | 25 ± 0.5 mm |
| Sleeve Bore Inner Diameter | Φ8 (+0.022 / +0) mm |
| Mounting Screw Specification | M4 x 6.5 |
| Impeller Material | AS + GF30% |
| Rotation Direction | Counter-Clockwise (CCW from Steel Shaft End) |
| Color | Black |
According to the technical requirements specified on the drawing, blade connections are welded by noise wave, requiring smooth outer blade surfaces without burrs or cracks. Specified drawing tolerances allow a maximum radial runout of 0.7 mm, axial runout of 0.6 mm, and shaft runout of 0.2 mm. Dynamic balance requirements specify a maximum remaining unbalance of 0.3 g or less under 1200 rpm conditions.

Request a custom cross flow fan evaluation
If your application requires a custom plastic cross flow fan impeller, submit your mechanical and performance requirements to LONGWELL. Provide required dimensions, mounting options, shaft size, and operating parameters via our contact page or explore standard options using the LONGWELL Fan Selector Tool.
Choose the right cross flow fan
Longwell manufactures 495 cross flow fans in-house. Send airflow, static pressure and voltage — an engineer replies with a matching model, performance curve and price within one working day.