LONGWELL AT 10-8L2 Belt-Driven Forward-Curved Centrifugal Blower — 400–9,000 m³/h, up to 1,400 Pa

Air Flow 400–9,000 m³/h
Static Pressure 120–1,400 Pa (total pressure)
Inlet Ø 425×443 mm
Voltage Motor selected to duty — 220/380/415 V available

$ 10

AT 10-8L2 belt-driven forward-curved centrifugal blower, construction type L2, 425×443 mm housing. Catalogue operating envelope 400–9,000 m³/h at up to 1,400 Pa, 700–1,900 rpm.

Specifications
Noise
65–90 dB(A) (Sound power level LwiA)
Motor
AC (belt-driven, motor selected separately)
Speed
700–1,900 rpm
Frequency
50 / 60 Hz
Get a Fast Quote from an Engineer Send your airflow, static pressure & voltage — we reply within one working day with a matching model.
✓ 1-day reply ✓ STEP / CAD on request ✓ Factory-direct

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Your specifications go straight to a sales engineer — no spam, never shared.

Prefer a datasheet?
Download Product Catalog (PDF)
Need the exact model with a measured or digitised curve? This page describes the Industrial Centrifugal Fan range. The Fan Selector lists every LONGWELL centrifugal fan model with airflow, static pressure, power, noise, drawing and datasheet.
Search centrifugal fan models →
Have your duty point?

See every LONGWELL model whose P-Q curve covers it — margins, noise and power included. No login.

Library: Ø25–1,000 mm, single units up to about 52,000 m³/h — larger duties go straight to an engineer. Prefer to talk it through? Send your specs to an engineer

Description

AT 10-8L2 — Belt-Driven Forward-Curved Centrifugal Blower

The LONGWELL AT 10-8L2 is a forward-curved (multi-wing) centrifugal blower from the AT belt-driven commercial range. Per the AT series type code, 10 is the impeller diameter designation and 8 the impeller width designation; Construction type L2 (AT series type code). The casing measures 425×443 mm housing (dimensions A–B below). Because the fan is belt-driven, the duty point is set by the pulley ratio you choose — the figures below are the operating envelope printed on the AT 10-8 catalogue performance chart, not a single rated point.

LONGWELL states the AT series covers 1,000–40,000 m³/h overall, and is characterised by compact construction, high efficiency and low noise. Catalogue performance is quoted at standard conditions (inlet pressure 101.325 kPa).

Performance envelope

Volume flow rate 400 – 9,000 m³/h
Total pressure Pt 120 – 1,400 Pa
Rotational speed 700 – 1,900 rpm
Impeller power 0.06 – 4 kW
Sound power level LwiA 65 – 90 dB(A)
Total efficiency η up to 63%

Send us your required airflow and static pressure and our engineers will return the matching speed, pulley set and motor rating.

Dimensions (mm)

A 425 mm
B 443 mm
C 289 mm
D 249 mm
E 340 mm
J 265 mm
K 291 mm
L 794 mm
M 90 mm
N 203 mm
P 214 mm
Q 924 mm
V 188 mm
W 60 mm
X 28 mm
X1 136 mm
X2 132 mm
X3 135 mm
H1 287 mm
H2 227 mm
H3 198 mm
d 25 mm
t 8 mm
t1 7 mm

Letter codes correspond to the AT series dimensional drawing shown below. All values from the LONGWELL AT series catalogue.

Performance curves

LONGWELL AT 10-8L2 performance curves

Dimensional drawing

LONGWELL AT 10-8L2 dimensional drawing

The Company Longwell Leading Fan and Motor Innovator Worldwide

As a leading supplier of ventilation and drive technology, LONGWELL is a highly respected engineering partner in many industries. With over than 20,000 different products, we provide the right solution for every need. And we have always worked according to the highest economic and ecological standards.

LONGWELL Product Line

LONGWELL product line

LONGWELL Certificate

LONGWELL Certificate

Additional information

Model

AT 10-8L2

Construction type

L2

Type

Forward-curved (multi-wing) centrifugal blower, belt-driven

Material

Metal

Airflow

400–9,000 m³/h

Total pressure

120–1,400 Pa (total pressure)

Speed

700–1,900 rpm

Noise

65–90 dB(A) (Sound power level LwiA)

Sound power

65–90 dB(A)

Dimensions

425×443 mm

Voltage

Motor selected to duty — 220/380/415 V available

Frequency

50 / 60 Hz

Motor type

AC (belt-driven, motor selected separately)

Reviews

There are no reviews yet.

Be the first to review “LONGWELL AT 10-8L2 Belt-Driven Forward-Curved Centrifugal Blower — 400–9,000 m³/h, up to 1,400 Pa”

Your email address will not be published. Required fields are marked *

More in this series

LONGWELL 500mm Centrifugal Blower Fan, Industrial Centrifugal Fan, 11000 m³/h Airflow, 910 Pa Static Pressure, for HVAC Systems – LWFA-E-500-02LONGWELL 500mm Centrifugal Blower Fan, Industrial Centrifugal Fan, 11000 m³/h Airflow, 910 Pa Static Pressure, for HVAC Systems – LWFA-E-500-02500 mm11000-18000 m³/h910-750 PaDatasheet, curve & drawing →LONGWELL 500mm EC Centrifugal Blower Fan, Industrial Centrifugal Fan, 400V, for AHU, Cold Storage, Air PurifiersLONGWELL 500mm EC Centrifugal Blower Fan, Industrial Centrifugal Fan, 400V, for AHU, Cold Storage, Air Purifiers400 VFree StandingView & InquireLONGWELL AT 15-15L2 Belt-Driven Forward-Curved Centrifugal Blower — 1,500–18,000 m³/h, up to 1,500 PaLONGWELL AT 15-15L2 Belt-Driven Forward-Curved Centrifugal Blower — 1,500–18,000 m³/h, up to 1,500 Pa569×609 mm1 m³/hMotor selected to duty — 220/380/415 V availableView & InquireLONGWELL AT 18-13LK Belt-Driven Forward-Curved Centrifugal Blower — 1,300–20,000 m³/h, up to 900 PaLONGWELL AT 18-13LK Belt-Driven Forward-Curved Centrifugal Blower — 1,300–20,000 m³/h, up to 900 Pa684×739 mm1 m³/hMotor selected to duty — 220/380/415 V availableView & InquireLONGWELL AT 9-7L2 Belt-Driven Forward-Curved Centrifugal Blower — 400–9,000 m³/h, up to 1,400 PaLONGWELL AT 9-7L2 Belt-Driven Forward-Curved Centrifugal Blower — 400–9,000 m³/h, up to 1,400 Pa380×387 mm400–9Motor selected to duty — 220/380/415 V availableView & InquireLONGWELL 200mm Centrifugal Blower Fan, Industrial Centrifugal FanLONGWELL 200mm Centrifugal Blower Fan, Industrial Centrifugal Fan200 mmView & InquireLONGWELL AT 10-10L Belt-Driven Forward-Curved Centrifugal Blower — 800–10,000 m³/h, up to 1,100 PaLONGWELL AT 10-10L Belt-Driven Forward-Curved Centrifugal Blower — 800–10,000 m³/h, up to 1,100 Pa430×446 mm800–10Motor selected to duty — 220/380/415 V availableView & InquireLONGWELL EC Centrifugal Blower Fan, Industrial Centrifugal Fan, 380V, for Control Cabinet Cooling, HVAC Systems, AHU – LWLONGWELL EC Centrifugal Blower Fan, Industrial Centrifugal Fan, 380V, for Control Cabinet Cooling, HVAC Systems, AHU – LW380V(as requiremnts)Internal rotor motorView & InquireLONGWELL AT 9-9R2 Belt-Driven Forward-Curved Centrifugal Blower — 400–9,000 m³/h, up to 1,000 PaLONGWELL AT 9-9R2 Belt-Driven Forward-Curved Centrifugal Blower — 400–9,000 m³/h, up to 1,000 Pa385×397 mm400–9Motor selected to duty — 220/380/415 V availableView & InquireLONGWELL 315mm Centrifugal Blower Fan, Industrial Centrifugal FanLONGWELL 315mm Centrifugal Blower Fan, Industrial Centrifugal Fan315 mmView & Inquire

Related for the same application

LONGWELL 500mm AC Axial Fan, Industrial Axial Ventilation Fan, 220/230V IP55, 7004 m³/h Airflow – LWAA4E500S-5MEB-02LONGWELL 500mm AC Axial Fan, Industrial Axial Ventilation Fan, 220/230V IP55, 7004 m³/h Airflow – LWAA4E500S-5MEB-02500 mm7004 m³/h220/230 VDatasheet, curve & drawing →LONGWELL 10mm AC Centrifugal Blower Fan, Industrial Centrifugal Fan, 230V, 450 WLONGWELL 10mm AC Centrifugal Blower Fan, Industrial Centrifugal Fan, 230V, 450 W10-10 mm230 V850 rpmView & InquireLONGWELL 200mm EC Forward Curved Centrifugal Blower, Forward Curved Blower Fan, 230V, Low Noise, for Cold Storage, Air Purifiers, HVAC SystemsLONGWELL 200mm EC Forward Curved Centrifugal Blower, Forward Curved Blower Fan, 230V, Low Noise, for Cold Storage, Air Purifiers, HVAC Systems230V4000rpmOtherView & InquireLONGWELL 102mm EC Centrifugal Blower Fan, Industrial Centrifugal Fan, 230V, 2575 m³/h Airflow, 464 Pa Static Pressure – LWFE3G200-102DS-02LONGWELL 102mm EC Centrifugal Blower Fan, Industrial Centrifugal Fan, 230V, 2575 m³/h Airflow, 464 Pa Static Pressure – LWFE3G200-102DS-02102 mm2575 m³/h230 VDatasheet, curve & drawing →LONGWELL LWBE3G250-072NS-18 EC Backward-Curved Centrifugal Fan — Ø250 mm Impeller, 230 VAC, Without housing / bracketLONGWELL LWBE3G250-072NS-18 EC Backward-Curved Centrifugal Fan — Ø250 mm Impeller, 230 VAC, Without housing / bracket72 mm1236 m³/h230 VDatasheet, curve & drawing →LONGWELL 80x25mm DC Axial Cooling Fan, Brushless DC Cooling Fan, 12V – LWAD8025LX-01LONGWELL 80x25mm DC Axial Cooling Fan, Brushless DC Cooling Fan, 12V – LWAD8025LX-0180x252.59 m³/h12 VDatasheet, curve & drawing →LONGWELL 92mm AC Centrifugal Blower Fan, Industrial Centrifugal Fan, 230V, 742 m³/h Airflow, 453 Pa Static Pressure – LWFA2E146-092DS-01LONGWELL 92mm AC Centrifugal Blower Fan, Industrial Centrifugal Fan, 230V, 742 m³/h Airflow, 453 Pa Static Pressure – LWFA2E146-092DS-0192 mm742 m³/h230 VDatasheet, curve & drawing →LONGWELL LWBE3G190-072NS-15 EC Backward-Curved Centrifugal Fan — Ø190 mm Impeller, 230 VAC, Without housing / bracketLONGWELL LWBE3G190-072NS-15 EC Backward-Curved Centrifugal Fan — Ø190 mm Impeller, 230 VAC, Without housing / bracket72 mm854.9 m³/h230 VDatasheet, curve & drawing →LONGWELL 138mm AC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 230V IP54, 4017 m³/h Airflow, 309 Pa Static Pressure – LWBA6E450-138NS-05LONGWELL 138mm AC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 230V IP54, 4017 m³/h Airflow, 309 Pa Static Pressure – LWBA6E450-138NS-05138 mm4017 m³/h230 VDatasheet, curve & drawing →LONGWELL 102mm AC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 380V IP54, 3245 m³/h Airflow, 515 Pa Static Pressure – LWBA4D355-102NT-10LONGWELL 102mm AC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 380V IP54, 3245 m³/h Airflow, 515 Pa Static Pressure – LWBA4D355-102NT-10102 mm3245 m³/h380 VDatasheet, curve & drawing →
Explore related
Free engineering calculators for this fan