LONGWELL AT 9-7R2 Belt-Driven Forward-Curved Centrifugal Blower — 400–9,000 m³/h, up to 1,400 Pa

Air Flow 400–9,000 m³/h
Static Pressure 50–1,400 Pa (total pressure)
Inlet Ø 385×399 mm
Voltage Motor selected to duty — 220/380/415 V available

$ 10

AT 9-7R2 belt-driven forward-curved centrifugal blower, construction type R2, 385×399 mm housing. Catalogue operating envelope 400–9,000 m³/h at up to 1,400 Pa, 600–2,200 rpm.

Specifications
Noise
50–85 dB(A) (Sound power level LwiA)
Motor
AC (belt-driven, motor selected separately)
Speed
600–2,200 rpm
Frequency
50 / 60 Hz
Get a Fast Quote from an Engineer Send your airflow, static pressure & voltage — we reply within one working day with a matching model.
✓ 1-day reply ✓ STEP / CAD on request ✓ Factory-direct

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Your specifications go straight to a sales engineer — no spam, never shared.

Prefer a datasheet?
Download Product Catalog (PDF)
Need the exact model with a measured or digitised curve? This page describes the Industrial Centrifugal Fan range. The Fan Selector lists every LONGWELL centrifugal fan model with airflow, static pressure, power, noise, drawing and datasheet.
Search centrifugal fan models →
Have your duty point?

See every LONGWELL model whose P-Q curve covers it — margins, noise and power included. No login.

Library: Ø25–1,000 mm, single units up to about 52,000 m³/h — larger duties go straight to an engineer. Prefer to talk it through? Send your specs to an engineer

Description

AT 9-7R2 — Belt-Driven Forward-Curved Centrifugal Blower

The LONGWELL AT 9-7R2 is a forward-curved (multi-wing) centrifugal blower from the AT belt-driven commercial range. Per the AT series type code, 9 is the impeller diameter designation and 7 the impeller width designation; Construction type R2 (AT series type code). The casing measures 385×399 mm housing (dimensions A–B below). Because the fan is belt-driven, the duty point is set by the pulley ratio you choose — the figures below are the operating envelope printed on the AT 9-7 catalogue performance chart, not a single rated point.

LONGWELL states the AT series covers 1,000–40,000 m³/h overall, and is characterised by compact construction, high efficiency and low noise. Catalogue performance is quoted at standard conditions (inlet pressure 101.325 kPa).

Performance envelope

Volume flow rate 400 – 9,000 m³/h
Total pressure Pt 50 – 1,400 Pa
Rotational speed 600 – 2,200 rpm
Impeller power 0.04 – 4 kW
Sound power level LwiA 50 – 85 dB(A)
Total efficiency η up to 58%

Send us your required airflow and static pressure and our engineers will return the matching speed, pulley set and motor rating.

Dimensions (mm)

A 385 mm
B 399 mm
C 262 mm
D 215 mm
E 274 mm
F 324 mm
G 349 mm
H 36 mm
J 232 mm
K 254 mm
L 688 mm
M 70 mm
N 185 mm
P 184 mm
Q 828 mm
R 6 mm
V 162 mm
W 60 mm
X 22.5 mm
d 20 mm
t 6 mm
t1 6 mm
U×S 9×12 mm

Letter codes correspond to the AT series dimensional drawing shown below. All values from the LONGWELL AT series catalogue.

Performance curves

LONGWELL AT 9-7R2 performance curves

Dimensional drawing

LONGWELL AT 9-7R2 dimensional drawing

The Company Longwell Leading Fan and Motor Innovator Worldwide

As a leading supplier of ventilation and drive technology, LONGWELL is a highly respected engineering partner in many industries. With over than 20,000 different products, we provide the right solution for every need. And we have always worked according to the highest economic and ecological standards.

LONGWELL Product Line

LONGWELL product line

LONGWELL Certificate

LONGWELL Certificate

Additional information

Model

AT 9-7R2

Construction type

R2

Type

Forward-curved (multi-wing) centrifugal blower, belt-driven

Material

Metal

Airflow

400–9,000 m³/h

Total pressure

50–1,400 Pa (total pressure)

Speed

600–2,200 rpm

Noise

50–85 dB(A) (Sound power level LwiA)

Sound power

50–85 dB(A)

Dimensions

385×399 mm

Voltage

Motor selected to duty — 220/380/415 V available

Frequency

50 / 60 Hz

Motor type

AC (belt-driven, motor selected separately)

Reviews

There are no reviews yet.

Be the first to review “LONGWELL AT 9-7R2 Belt-Driven Forward-Curved Centrifugal Blower — 400–9,000 m³/h, up to 1,400 Pa”

Your email address will not be published. Required fields are marked *

More in this series

LONGWELL AT 10-8R2 Belt-Driven Forward-Curved Centrifugal Blower — 400–9,000 m³/h, up to 1,400 PaLONGWELL AT 10-8R2 Belt-Driven Forward-Curved Centrifugal Blower — 400–9,000 m³/h, up to 1,400 Pa431×455 mm400–9Motor selected to duty — 220/380/415 V availableView & InquireLONGWELL AT 9-9L2 Belt-Driven Forward-Curved Centrifugal Blower — 400–9,000 m³/h, up to 1,000 PaLONGWELL AT 9-9L2 Belt-Driven Forward-Curved Centrifugal Blower — 400–9,000 m³/h, up to 1,000 Pa380×387 mm400–9Motor selected to duty — 220/380/415 V availableView & InquireLONGWELL AT 18-13L Belt-Driven Forward-Curved Centrifugal Blower — 1,300–20,000 m³/h, up to 900 PaLONGWELL AT 18-13L Belt-Driven Forward-Curved Centrifugal Blower — 1,300–20,000 m³/h, up to 900 Pa684×739 mm1 m³/hMotor selected to duty — 220/380/415 V availableView & InquireLONGWELL 250mm Centrifugal Blower Fan, Industrial Centrifugal Fan, 2500 m³/h Airflow, 380 Pa Static Pressure, for HVAC Systems – LWFA-E-250-01LONGWELL 250mm Centrifugal Blower Fan, Industrial Centrifugal Fan, 2500 m³/h Airflow, 380 Pa Static Pressure, for HVAC Systems – LWFA-E-250-01250 mm2500-3100 m³/h380-330 PaDatasheet, curve & drawing →LONGWELL 630mm Centrifugal Blower Fan, Industrial Centrifugal FanLONGWELL 630mm Centrifugal Blower Fan, Industrial Centrifugal Fan630 mmView & InquireLONGWELL 300mm Centrifugal Blower Fan, Industrial Centrifugal Fan, 2900 m³/h Airflow, 408 Pa Static Pressure, for HVAC Systems – LWFA-E-300-02LONGWELL 300mm Centrifugal Blower Fan, Industrial Centrifugal Fan, 2900 m³/h Airflow, 408 Pa Static Pressure, for HVAC Systems – LWFA-E-300-02300 mm2900-4000 m³/h408-385 PaDatasheet, curve & drawing →LWKXF2A Volute Casing General Ventilation Fan/LWKXF2B Kitchen Exhaust DedicatedLWKXF2A Volute Casing General Ventilation Fan/LWKXF2B Kitchen Exhaust Dedicated220 V720RPMAC motorView & InquireLONGWELL 450mm EC Centrifugal Blower Fan, Industrial Centrifugal Fan, 230V PWM Control, for HVAC Systems, AHU, FFU – LWBE3G450LONGWELL 450mm EC Centrifugal Blower Fan, Industrial Centrifugal Fan, 230V PWM Control, for HVAC Systems, AHU, FFU – LWBE3G450230V / 400V4000rpmEC external rotor motorView & InquireLONGWELL AT 18-18R2 Belt-Driven Forward-Curved Centrifugal Blower — 1,700–25,000 m³/h, up to 700 PaLONGWELL AT 18-18R2 Belt-Driven Forward-Curved Centrifugal Blower — 1,700–25,000 m³/h, up to 700 Pa690×751 mm1 m³/hMotor selected to duty — 220/380/415 V availableView & InquireLONGWELL AT 7-7L2 Belt-Driven Forward-Curved Centrifugal Blower — 400–8,000 m³/h, up to 950 PaLONGWELL AT 7-7L2 Belt-Driven Forward-Curved Centrifugal Blower — 400–8,000 m³/h, up to 950 Pa312×328 mm400–8Motor selected to duty — 220/380/415 V availableView & Inquire

Related for the same application

LONGWELL 92mm DC Centrifugal Blower Fan, Industrial Centrifugal Fan, 679.8 m³/h Airflow, 329.6 Pa Static Pressure – LWFD3G133-092DZ-02LONGWELL 92mm DC Centrifugal Blower Fan, Industrial Centrifugal Fan, 679.8 m³/h Airflow, 329.6 Pa Static Pressure – LWFD3G133-092DZ-0292 mm679.8 m³/h310 VDatasheet, curve & drawing →LONGWELL AT 8-8L Belt-Driven Forward-Curved Centrifugal Blower — 300–9,000 m³/h, up to 1,400 PaLONGWELL AT 8-8L Belt-Driven Forward-Curved Centrifugal Blower — 300–9,000 m³/h, up to 1,400 Pa346×365 mm300–9Motor selected to duty — 220/380/415 V availableView & InquireLONGWELL 72mm DC Centrifugal Blower Fan, Industrial Centrifugal Fan, 48V, 371 m³/h Airflow, 309 Pa Static Pressure – LWFD3G120-072SH-03LONGWELL 72mm DC Centrifugal Blower Fan, Industrial Centrifugal Fan, 48V, 371 m³/h Airflow, 309 Pa Static Pressure – LWFD3G120-072SH-0372 mm371 m³/h48 VDatasheet, curve & drawing →LONGWELL LWBE3G355-102PS-18 EC Backward-Curved Centrifugal Fan — Ø355 mm Impeller, 230 VAC, With bracketLONGWELL LWBE3G355-102PS-18 EC Backward-Curved Centrifugal Fan — Ø355 mm Impeller, 230 VAC, With bracket102 mm3915 m³/h230 VDatasheet, curve & drawing →LWFDF6-48 Dust Exhausting Centrifugal FanLWFDF6-48 Dust Exhausting Centrifugal Fan220 V400 RPMAC motorView & InquireLONGWELL LWBE3G250-092PS-21 EC Backward-Curved Centrifugal Fan — Ø250 mm Impeller, 230 VAC, With bracketLONGWELL LWBE3G250-092PS-21 EC Backward-Curved Centrifugal Fan — Ø250 mm Impeller, 230 VAC, With bracket92 mm1421 m³/h230 VDatasheet, curve & drawing →LONGWELL 250mm AC Axial Fan, Industrial Axial Ventilation Fan, 380/400V IP44, 1854 m³/h Airflow – LWAA2D250S-5MKW-12LONGWELL 250mm AC Axial Fan, Industrial Axial Ventilation Fan, 380/400V IP44, 1854 m³/h Airflow – LWAA2D250S-5MKW-12250 mm1854 m³/h380/400 VDatasheet, curve & drawing →LONGWELL 800mm EC Axial Fan, Industrial Axial Ventilation Fan, 380V IP55, 26587 m³/h Airflow – LWAE3G800TS-3PKW-02LONGWELL 800mm EC Axial Fan, Industrial Axial Ventilation Fan, 380V IP55, 26587 m³/h Airflow – LWAE3G800TS-3PKW-02800 mm26587 m³/h3-380 VDatasheet, curve & drawing →LONGWELL Industrial Fan, Industrial Ventilation FanLONGWELL Industrial Fan, Industrial Ventilation Fan2600-3900 m³/h380/220 V820-670 PaView & InquireLONGWELL 72mm DC Centrifugal Blower Fan, Industrial Centrifugal Fan, 48V, 1112.4 m³/h Airflow, 597.4 Pa Static Pressure – LWFD3G133-072DH-04LONGWELL 72mm DC Centrifugal Blower Fan, Industrial Centrifugal Fan, 48V, 1112.4 m³/h Airflow, 597.4 Pa Static Pressure – LWFD3G133-072DH-0472 mm1112.4 m³/h48 VDatasheet, curve & drawing →
Explore related
Free engineering calculators for this fan