LONGWELL AT 12-9R2 Belt-Driven Forward-Curved Centrifugal Blower — 800–10,500 m³/h, up to 1,250 Pa

Air Flow 800–10,500 m³/h
Static Pressure 80–1,250 Pa (total pressure)
Inlet Ø 494×527 mm
Voltage Motor selected to duty — 220/380/415 V available

$ 10

AT 12-9R2 belt-driven forward-curved centrifugal blower, construction type R2, 494×527 mm housing. Catalogue operating envelope 800–10,500 m³/h at up to 1,250 Pa, 500–1,600 rpm.

Specifications
Noise
55–90 dB(A) (Sound power level LwiA)
Motor
AC (belt-driven, motor selected separately)
Speed
500–1,600 rpm
Frequency
50 / 60 Hz
Get a Fast Quote from an Engineer Send your airflow, static pressure & voltage — we reply within one working day with a matching model.
✓ 1-day reply ✓ STEP / CAD on request ✓ Factory-direct

Your specifications go straight to a sales engineer — no spam, never shared.

Prefer a datasheet?
Download Product Catalog (PDF)
Need the exact model with a measured or digitised curve? This page describes the Industrial Centrifugal Fans range. The Fan Selector lists every LONGWELL industrial centrifugal fan model with airflow, static pressure, power, noise, drawing and datasheet.
Search industrial centrifugal fan models →
Have your duty point?

See every LONGWELL model whose P-Q curve covers it — margins, noise and power included. No login.

Library: Ø25–1,000 mm, single units up to about 52,000 m³/h — larger duties go straight to an engineer. Prefer to talk it through? Send your specs to an engineer

Description

AT 12-9R2 — Belt-Driven Forward-Curved Centrifugal Blower

The LONGWELL AT 12-9R2 is a forward-curved (multi-wing) centrifugal blower from the AT belt-driven commercial range. Per the AT series type code, 12 is the impeller diameter designation and 9 the impeller width designation; Construction type R2 (AT series type code). The casing measures 494×527 mm housing (dimensions A–B below). Because the fan is belt-driven, the duty point is set by the pulley ratio you choose — the figures below are the operating envelope printed on the AT 12-9 catalogue performance chart, not a single rated point.

LONGWELL states the AT series covers 1,000–40,000 m³/h overall, and is characterised by compact construction, high efficiency and low noise. Catalogue performance is quoted at standard conditions (inlet pressure 101.325 kPa).

Performance envelope

Volume flow rate 800 – 10,500 m³/h
Total pressure Pt 80 – 1,250 Pa
Rotational speed 500 – 1,600 rpm
Impeller power 0.06 – 6 kW
Sound power level LwiA 55 – 90 dB(A)
Total efficiency η up to 71%

Send us your required airflow and static pressure and our engineers will return the matching speed, pulley set and motor rating.

Dimensions (mm)

A 494 mm
B 527 mm
C 341 mm
D 294 mm
E 371 mm
F 443 mm
G 458 mm
H 36 mm
J 309 mm
K 339 mm
L 918 mm
M 82 mm
N 230 mm
P 244 mm
Q 1082 mm
R 3 mm
V 214 mm
W 60 mm
X 28 mm
d 25 mm
t 8 mm
t1 7 mm
U×S 11×16 mm

Letter codes correspond to the AT series dimensional drawing shown below. All values from the LONGWELL AT series catalogue.

Performance curves

LONGWELL AT 12-9R2 performance curves

Dimensional drawing

LONGWELL AT 12-9R2 dimensional drawing

The Company Longwell Leading Fan and Motor Innovator Worldwide

As a leading supplier of ventilation and drive technology, LONGWELL is a highly respected engineering partner in many industries. With over than 20,000 different products, we provide the right solution for every need. And we have always worked according to the highest economic and ecological standards.

LONGWELL Product Line

LONGWELL product line

LONGWELL Certificate

LONGWELL Certificate

Additional information

Model

AT 12-9R2

Construction type

R2

Type

Forward-curved (multi-wing) centrifugal blower, belt-driven

Material

Metal

Airflow

800–10,500 m³/h

Total pressure

80–1,250 Pa (total pressure)

Speed

500–1,600 rpm

Noise

55–90 dB(A) (Sound power level LwiA)

Sound power

55–90 dB(A)

Dimensions

494×527 mm

Voltage

Motor selected to duty — 220/380/415 V available

Frequency

50 / 60 Hz

Motor type

AC (belt-driven, motor selected separately)

Reviews

There are no reviews yet.

Be the first to review “LONGWELL AT 12-9R2 Belt-Driven Forward-Curved Centrifugal Blower — 800–10,500 m³/h, up to 1,250 Pa”

Your email address will not be published. Required fields are marked *

More in this series

LONGWELL 355mm Centrifugal Blower Fan, Industrial Centrifugal FanLONGWELL 355mm Centrifugal Blower Fan, Industrial Centrifugal Fan355 mmView & InquireLONGWELL AT 9-9L2 Belt-Driven Forward-Curved Centrifugal Blower — 400–9,000 m³/h, up to 1,000 PaLONGWELL AT 9-9L2 Belt-Driven Forward-Curved Centrifugal Blower — 400–9,000 m³/h, up to 1,000 Pa380×387 mm400–9Motor selected to duty — 220/380/415 V availableView & InquireLONGWELL 450mm Centrifugal Blower Fan, Industrial Centrifugal Fan, 10500 m³/h Airflow, 750 Pa Static Pressure, for HVAC Systems – LWFA-E-450-02LONGWELL 450mm Centrifugal Blower Fan, Industrial Centrifugal Fan, 10500 m³/h Airflow, 750 Pa Static Pressure, for HVAC Systems – LWFA-E-450-02450 mm10500-16000 m³/h750-700 PaDatasheet, curve & drawing →LONGWELL AC Centrifugal Blower Fan, Industrial Centrifugal Fan, 110V, Low Noise, for Boilers, AHU, FFULONGWELL AC Centrifugal Blower Fan, Industrial Centrifugal Fan, 110V, Low Noise, for Boilers, AHU, FFU110v /220v 24VDC/ 48VDCexternal rotor motorView & InquireLONGWELL 300mm Centrifugal Blower Fan, Industrial Centrifugal Fan, 2900 m³/h Airflow, 408 Pa Static Pressure, for HVAC Systems – LWFA-E-300-02LONGWELL 300mm Centrifugal Blower Fan, Industrial Centrifugal Fan, 2900 m³/h Airflow, 408 Pa Static Pressure, for HVAC Systems – LWFA-E-300-02300 mm2900-4000 m³/h408-385 PaDatasheet, curve & drawing →LONGWELL 280mm AC Centrifugal Blower Fan, Industrial Centrifugal Fan, 380V, Galvanized Steel, for Data Center Cooling, Cold Storage, Air PurifiersLONGWELL 280mm AC Centrifugal Blower Fan, Industrial Centrifugal Fan, 380V, Galvanized Steel, for Data Center Cooling, Cold Storage, Air Purifiers4in380V4000rpmView & InquireLONGWELL DC Gas Blower, Industrial Gas Blower Fan, 24V, 42 W, for Gas Transmission – LWGD108M-01LONGWELL DC Gas Blower, Industrial Gas Blower Fan, 24V, 42 W, for Gas Transmission – LWGD108M-0124V3700 rpmOtherView & InquireLONGWELL 8mm EC Centrifugal Blower Fan, Industrial Centrifugal Fan, 220V, 835 m³/h Airflow, 403 Pa Static Pressure – LWDD8-7-ECLONGWELL 8mm EC Centrifugal Blower Fan, Industrial Centrifugal Fan, 220V, 835 m³/h Airflow, 403 Pa Static Pressure – LWDD8-7-EC8-7 mm835~2916 m³/h220 VDatasheet, curve & drawing →LONGWELL AT 10-8L Belt-Driven Forward-Curved Centrifugal Blower — 400–9,000 m³/h, up to 1,400 PaLONGWELL AT 10-8L Belt-Driven Forward-Curved Centrifugal Blower — 400–9,000 m³/h, up to 1,400 Pa430×446 mm400–9Motor selected to duty — 220/380/415 V availableView & InquireLONGWELL AT 15-15R2 Belt-Driven Forward-Curved Centrifugal Blower — 1,500–18,000 m³/h, up to 1,500 PaLONGWELL AT 15-15R2 Belt-Driven Forward-Curved Centrifugal Blower — 1,500–18,000 m³/h, up to 1,500 Pa575×619 mm1 m³/hMotor selected to duty — 220/380/415 V availableView & Inquire

Related for the same application

LONGWELL 72mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 230V IP55, 2317.5 m³/h Airflow, 556.2 Pa Static Pressure – LWFE3G280-072PS-01LONGWELL 72mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 230V IP55, 2317.5 m³/h Airflow, 556.2 Pa Static Pressure – LWFE3G280-072PS-0172 mm2317.5 m³/h230 VDatasheet, curve & drawing →LONGWELL AT 10-8L Belt-Driven Forward-Curved Centrifugal Blower — 400–9,000 m³/h, up to 1,400 PaLONGWELL AT 10-8L Belt-Driven Forward-Curved Centrifugal Blower — 400–9,000 m³/h, up to 1,400 Pa430×446 mm400–9Motor selected to duty — 220/380/415 V availableView & InquireLONGWELL 400mm AC Axial Fan, Industrial Axial Ventilation Fan, 110/120V, 11000 m³/h Airflow – LWA-400LONGWELL 400mm AC Axial Fan, Industrial Axial Ventilation Fan, 110/120V, 11000 m³/h Airflow – LWA-400400 mm11000 m³/h110-120/220-240 VDatasheet, curve & drawing →LONGWELL 102mm AC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 380V IP54, 3090 m³/h Airflow, 515 Pa Static Pressure – LWBA4D400-102NT-04LONGWELL 102mm AC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 380V IP54, 3090 m³/h Airflow, 515 Pa Static Pressure – LWBA4D400-102NT-04102 mm3090 m³/h380 VDatasheet, curve & drawing →LONGWELL 92mm AC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 380V IP44, 937 m³/h Airflow, 484 Pa Static Pressure – LWBA2D220-092NT-06LONGWELL 92mm AC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 380V IP44, 937 m³/h Airflow, 484 Pa Static Pressure – LWBA2D220-092NT-0692 mm937 m³/h380 VDatasheet, curve & drawing →LONGWELL 92mm AC Centrifugal Blower Fan, Industrial Centrifugal Fan, 230V, 433 m³/h Airflow, 309 Pa Static Pressure – LWFA2E120-092DS-03LONGWELL 92mm AC Centrifugal Blower Fan, Industrial Centrifugal Fan, 230V, 433 m³/h Airflow, 309 Pa Static Pressure – LWFA2E120-092DS-0392 mm433 m³/h230 VDatasheet, curve & drawing →LONGWELL 550mm EC Axial Fan, Industrial Axial Ventilation Fan, 380V IP54, 12154 m³/h Airflow – LWAE3G550TS-5MNW-01LONGWELL 550mm EC Axial Fan, Industrial Axial Ventilation Fan, 380V IP54, 12154 m³/h Airflow – LWAE3G550TS-5MNW-01550 mm12154 m³/h3-380 VDatasheet, curve & drawing →LONGWELL 400mm EC Axial Fan, Industrial Axial Ventilation Fan, 220V IP54, 4944 m³/h Airflow – LWAE3G400SS-5MNW-01LONGWELL 400mm EC Axial Fan, Industrial Axial Ventilation Fan, 220V IP54, 4944 m³/h Airflow – LWAE3G400SS-5MNW-01400 mm4944 m³/h220 VDatasheet, curve & drawing →LONGWELL 102mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 400V IP55, 8652 m³/h Airflow, 1390.5 Pa Static Pressure – LWFE3G450-102PT-06LONGWELL 102mm EC Backward Curved Centrifugal Fan, Industrial Centrifugal Blower, 400V IP55, 8652 m³/h Airflow, 1390.5 Pa Static Pressure – LWFE3G450-102PT-06102 mm8652 m³/h400 VDatasheet, curve & drawing →LONGWELL AT 9-9R2 Belt-Driven Forward-Curved Centrifugal Blower — 400–9,000 m³/h, up to 1,000 PaLONGWELL AT 9-9R2 Belt-Driven Forward-Curved Centrifugal Blower — 400–9,000 m³/h, up to 1,000 Pa385×397 mm400–9Motor selected to duty — 220/380/415 V availableView & Inquire
Explore related
Free engineering calculators for this fan