Looking for an alternative for ebm-papst RadiPac 310? The LONGWELL LWBE3G-310-RDP is the dimensionally interchangeable equivalent — same mounting, same control protocol, AMCA 210/211 third-party-tested performance — at 40–55% lower landed cost with 15-day delivery vs 16–22 weeks ex-works ebm-papst. Widely deployed across RDHx rear-door coolers, edge data center FFU, in-row cooling 20–35 kW/rack.
RadiPac 310
LWBE3G-310-RDP
Specification Comparison
| Specification | ebm-papst RadiPac 310 | LONGWELL LWBE3G-310-RDP |
|---|---|---|
| Fan type | EC plug fan pre-assembled FFU module | EC plug fan pre-assembled FFU module |
| Impeller diameter | Ø310 mm | Ø310 mm Drop-in |
| Airflow range | 650–3,500 m³/h | 650–3,500 m³/h |
| Static pressure (max) | 1050 Pa | 1050 Pa |
| Motor power (max) | 650 W | 650 W |
| Wire-to-air η peak (AMCA 210) | 89% | 86% |
| Noise floor (Lw) | 65 dB(A) | 68 dB(A) |
| Voltage | 200–240 V 1Φ | 200–240 V 1Φ |
| Control input | 0–10 V / PWM / Modbus / EC-Control | 0–10 V / PWM / Modbus RTU / Modbus TCP Compatible |
| IP rating | IP54 / IP55 | IP54 std · IP55 / IP67 option |
| Certifications | CE · UL · VDE · EAC | CE · UL · cUL · TÜV · ATEX · VDE · EAC · RoHS · REACH |
| Sample lead time | 4–10 weeks | 1–3 days |
| Series lead time (≤500 units) | 16–22 weeks | 15–30 days |
| Landed cost index (LONGWELL = 100) | 175–200 | 100 (baseline) |
Why Engineers Switch from RadiPac 310 to LWBE3G-310-RDP
4–8× Faster Delivery
40–55% Lower Landed Cost
True Drop-In Compatibility
Drop-In Compatibility Details
Mechanical match
The LONGWELL LWBE3G-310-RDP matches the ebm-papst RadiPac 310 mounting pattern (M-mount, ISO 9001 plenum-fan footprint) within ±0.5 mm tolerance. Inlet ring diameter, motor shaft height, and electrical termination box position are identical. Drop-in retrofit requires no AHU rework, no plate modification, and no plenum hole resizing.
Electrical & control match
The LWBE3G-310-RDP accepts the same 0–10 V analog speed reference, PWM (1 kHz), and Modbus RTU (RS485) control signals as ebm-papst RadiPac 310. Default Modbus register map is compatible with the ebm-papst ecosystem; LONGWELL provides a free Modbus map cross-reference for BMS integration. ebm-papst-specific proprietary protocols (EC-Control bus / ZA-control) are bridged via a free MODBUS gateway available from LONGWELL Engineering — no BMS reprogramming required.
Performance match
The PQ curve of LONGWELL LWBE3G-310-RDP sits within 2–3% of the ebm-papst RadiPac 310 curve across the full operating envelope (verified by third-party AMCA 210/211 testing at TÜV and Intertek labs). Wire-to-air efficiency at BEP is 86% vs 89% for ebm-papst (3 pp delta at peak). In typical part-load HVAC duty, the gap narrows to within 1 pp.
Typical Applications
The LWBE3G-310-RDP is widely deployed across RDHx rear-door coolers, edge data center FFU, in-row cooling 20–35 kW/rack. Common application categories include:
- RDHx 20–35 kW/rack
- FFU compact
- Small data center retrofit
Particularly suited for RDHx rear-door coolers in AI data center retrofit projects.
FAQ
Is LONGWELL LWBE3G-310-RDP a true drop-in replacement for ebm-papst RadiPac 310?
How does LWBE3G-310-RDP compare on efficiency to RadiPac 310?
What's the 2026 lead time difference?
What's the cost delta?
What applications is LWBE3G-310-RDP typically used for?
Replace your RadiPac 310 in 5 days
Send a quick request — model + quantity + delivery address. Sample unit ships in 1–3 days for field validation. Series production at 15-day lead time after PO.
Request Sample View Full Cross-Reference Table