ebm-papst R3G310 Alternative — LONGWELL LWBE3G310
Looking for an alternative for ebm-papst R3G310-AI39-71? The LONGWELL LWBE3G310 is the same-size alternative — same control protocol, mounting dimensions on the LONGWELL drawing, performance characterized using AMCA 210/211 test methods (test report on request) — at 40–55% lower landed cost with 15–30 day delivery vs 14–22 weeks ex-works ebm-papst. Widely deployed across data-center CRAH, commercial AHU, cold-chain condensing units.
R3G310
LWBE3G310
Specification Comparison
| Specification | ebm-papst R3G310 | LONGWELL LWBE3G310 |
|---|---|---|
| Fan type | EC backward-curved centrifugal | EC backward-curved centrifugal |
| Impeller diameter | Ø310 mm | Ø310 mm 24 models |
| Airflow range | up to 3,500 m³/h | up to 5,593 m³/h |
| Static pressure (max) | up to 670 Pa | up to 1,730 Pa |
| Motor power (max) | ≈500 W | up to 1,588 W |
| Noise floor (Lw) | 72 dB(A) | from 63 dB(A) (nameplate, per model) |
| Voltage | 200–277 V | 220–230 / 115 V 1Φ · 380–400 V 3Φ |
| Control input | 0–10 V / PWM / Modbus / EC-Control | 0–10 V / PWM / Modbus RTU (RS485) |
| Certifications | CE · UL · VDE · EAC | CE · RoHS · REACH · ETL on single-phase 115/230 V versions (UL 507 / CSA C22.2 No.113) |
| Sample lead time | 4–10 weeks | 1–3 days |
| Series lead time (≤500 units) | 14–22 weeks | 15–30 days |
| Landed cost index (LONGWELL = 100) | 175–200 | 100 (baseline) |
Why Engineers Switch from R3G310 to LWBE3G310
4–8× Faster Delivery
40–55% Lower Landed Cost
Drop-in Candidate · Same Size Class
Drop-in compatibility: what matches and what to confirm
Mechanical match
The LONGWELL LWBE3G310 matches the ebm-papst R3G310 mounting pattern (plenum-fan footprint, inlet ring diameter, motor shaft height, terminal-box position) per the mounting dimensions on the LONGWELL drawing. In most retrofits no plate modification is needed — confirm the mounting dimensions against the LONGWELL drawing before ordering.
Electrical & control match
The LWBE3G310 accepts the same 0–10 V analog speed reference, PWM (1 kHz), and Modbus RTU (RS485) control signals as ebm-papst R3G310. LONGWELL provides the Modbus register map and a cross-reference to the ebm-papst map for BMS integration. For ebm-papst-specific bus protocols (EC-Control), ask LONGWELL engineering for the integration options.
Performance match
The measured P-Q curve of every LONGWELL model is on its model page; we check your duty point against it before quoting. The LWBE3G310-092PS-08 match is an energy-saving selection at the stated duty point.
Typical Applications
The LWBE3G310 is widely deployed across mid-range data-center CRAH and commercial AHU. Common application categories include:
- Data-center mid-range CRAH
- Commercial AHU
- Cold-chain condensing units
A high-volume retrofit size for mid-range data-center and commercial AHU plug-fan replacements.
FAQ
Is LONGWELL LWBE3G310 a true drop-in replacement for ebm-papst R3G310?
How does LWBE3G310 compare on efficiency to R3G310?
What's the 2026 lead time difference?
What's the cost delta?
Is R3G the same as K3G?
Replace your R3G310 — samples in 1–3 days
Send a quick request — model + quantity + delivery address. Sample unit ships in 1–3 days for field validation. Series production at 15–30 day lead time after PO.
Request Sample View Full Cross-Reference Table