Ziehl-Abegg FN091 Alternative — LONGWELL LWAE3G900
Looking for an alternative for Ziehl-Abegg FN091-ZIQ.GG.A7? The LONGWELL LWAE3G900 has the same impeller diameter. Catalogue ratings, measured curves and dimensioned drawings for every model are on the LONGWELL Fan Selector; final selection is made at your duty point. Typical applications: hyperscale data center free cooling, cooling tower, large dry cooler.
LWAE3G900
Specification Comparison
| Specification | Ziehl-Abegg FN091 | LONGWELL LWAE3G900 |
|---|---|---|
| Fan type | EC axial fan | EC axial fan |
| Impeller diameter | Ø910 mm | Ø910 mm 2 models |
| Airflow range | 11,000–34,000 m³/h | up to 32,313 m³/h |
| Static pressure (max) | 380 Pa | up to 365 Pa |
| Motor power (max) | 8,500 W | up to 2,785 W |
| Noise floor (Lw) | 82 dB(A) | from 76 dB(A) (nameplate, per model) |
| Voltage | 380–480 V 3Φ | 380–400 V 3Φ |
| Control input | 0–10 V / PWM / Modbus / EC-Control | 0–10 V / PWM / Modbus RTU (RS485) |
| IP rating | IP54 / IP55 | IP54 (per model) |
| Certifications | CE · UL · VDE · EAC | CE · RoHS |
| Sample lead time | Per manufacturer quotation | 1–3 days |
| Series lead time (≤500 units) | Per manufacturer quotation | 15–30 days |
| Pricing | Per manufacturer quotation | Quoted per project |
LWAE3G900 at a glance
Production Lead Time
Pricing
Same Impeller Diameter
Installation and control: what to check
Mechanical
Mounting dimensions, inlet ring diameter, motor shaft height and terminal-box position of the LONGWELL LWAE3G900 are given on its dimensioned drawing. Compare them with the installed fan before ordering.
Electrical & control
The LONGWELL LWAE3G900 accepts a 0–10 V analog speed reference, PWM and Modbus RTU (RS485) control signals (per model; see the model datasheet). LONGWELL supplies its Modbus RTU register map with the fan so the BMS points can be re-mapped; the register addresses are not identical to the Ziehl-Abegg map.For other bus protocols, ask LONGWELL engineering for the integration options.
Performance
The measured P-Q curve of every LONGWELL model is on its model page; we check your duty point against it before quoting.
Typical Applications
The LWAE3G900 is typically specified for hyperscale data center free cooling, cooling tower, large dry cooler. Common application categories include:
- Hyperscale free cooling
- Cooling tower
- Large dry cooler
Particularly suited for hyperscale data center free cooling at coil-array scale.
FAQ
What should I check before using LONGWELL LWAE3G900 in place of Ziehl-Abegg FN091?
Where can I find efficiency data for LWAE3G900?
What is the LONGWELL lead time?
How is LONGWELL pricing determined?
What applications is LWAE3G900 typically used for?
Evaluate a LONGWELL alternative to FN091 — samples in 1–3 days
Send a quick request — model + quantity + delivery address. Sample unit ships in 1–3 days for field validation. Series production at 15–30 day lead time after PO.