ebm-papst RadiPac 500 Alternative — LONGWELL LWBE3G500
Looking for an alternative for ebm-papst RadiPac 500? The LONGWELL LWBE3G500 is the same-size alternative — same control protocol, mounting dimensions on the LONGWELL drawing, performance characterized using AMCA 210/211 test methods (test report on request) — at 40–55% lower landed cost with 15–30 day delivery vs 16–22 weeks ex-works ebm-papst. Widely deployed across L2A 60–100 kW/rack modules, CRAH FanGrid, premium CDU.
RadiPac 500
LWBE3G500
Specification Comparison
| Specification | ebm-papst RadiPac 500 | LONGWELL LWBE3G500 |
|---|---|---|
| Fan type | EC plug fan pre-assembled FFU module | EC plug fan pre-assembled FFU module |
| Impeller diameter | Ø500 mm | Ø500 mm 10 models |
| Airflow range | 1,200–8,200 m³/h | up to 14,214 m³/h |
| Static pressure (max) | 1800 Pa | up to 1,541 Pa |
| Motor power (max) | 3,000 W | up to 4,200 W |
| Noise floor (Lw) | 37 dB(A) | from 66 dB(A) (nameplate, per model) |
| Voltage | 380–480 V 3Φ | 380–400 V 3Φ |
| Control input | 0–10 V / PWM / Modbus / EC-Control | 0–10 V / PWM / Modbus RTU (RS485) |
| IP rating | IP54 / IP55 | IP54 std · IP55 / IP67 option |
| Certifications | CE · UL · VDE · EAC | CE · RoHS · REACH · ETL on request |
| Sample lead time | 4–10 weeks | 1–3 days |
| Series lead time (≤500 units) | 16–22 weeks | 15–30 days |
| Landed cost index (LONGWELL = 100) | 175–200 | 100 (baseline) |
Why Engineers Switch from RadiPac 500 to LWBE3G500
4–8× Faster Delivery
40–55% Lower Landed Cost
Drop-in Candidate · Same Size Class
Drop-in compatibility: what matches and what to confirm
Mechanical match
The LONGWELL LWBE3G500 matches the ebm-papst RadiPac 500 mounting pattern (M-mount, ISO 9001 plenum-fan footprint) per the mounting dimensions on the LONGWELL drawing. Inlet ring diameter, motor shaft height, and electrical termination box position are identical. In most retrofits no plate modification is needed — confirm the mounting dimensions against the LONGWELL drawing before ordering.
Electrical & control match
The LWBE3G500 accepts the same 0–10 V analog speed reference, PWM (1 kHz), and Modbus RTU (RS485) control signals as ebm-papst RadiPac 500. LONGWELL provides the Modbus register map and a cross-reference to the ebm-papst map for BMS integration.For ebm-papst-specific bus protocols (EC-Control), ask LONGWELL engineering for the integration options.
Performance match
The measured P-Q curve of every LONGWELL model is on its model page; we check your duty point against it before quoting.
Typical Applications
The LWBE3G500 is widely deployed across L2A 60–100 kW/rack modules, CRAH FanGrid, premium CDU. Common application categories include:
- L2A 60–100 kW/rack
- CRAH FanGrid module
- Premium CDU
Particularly suited for 60–100 kW/rack L2A modules for AI training campus.
FAQ
Is LONGWELL LWBE3G500 a true drop-in replacement for ebm-papst RadiPac 500?
How does LWBE3G500 compare on efficiency to RadiPac 500?
What's the 2026 lead time difference?
What's the cost delta?
What applications is LWBE3G500 typically used for?
Replace your RadiPac 500 — samples in 1–3 days
Send a quick request — model + quantity + delivery address. Sample unit ships in 1–3 days for field validation. Series production at 15–30 day lead time after PO.
Request Sample View Full Cross-Reference Table