Application principle · Wastewater odor biofilter

How a Biofilter Uses a Fan to Collect and Treat Odor

Covering an odor source helps only if the released air follows a controlled route. An extraction fan draws air from the enclosure toward a biofilter.

English narration and captions · 85 seconds · Equipment and flow paths are schematic. Product-family images are identified separately below.
Inside the equipment

Follow the air through the process

01

The duct delivers air to the filter bed

In this arrangement, the fan feeds a distribution space beneath the bed. Air rises through the open spaces in the media. The collection duct, humidification section and bed all add resistance.

02

The moist surface is the transfer point

Odorous compounds move from the air into moisture on the media surface. Microorganisms in the biofilm then break down suitable compounds. The fan transports air; the biology performs the treatment.

03

Keep both air contact and moisture

The media needs the specified moisture and contact conditions. A dry area or an easy channel through the bed can reduce useful treatment. Simply increasing the fan speed does not repair the biological process.

04

Verify collection and treatment together

Check the enclosure capture, flow distribution and condition of the media. The required airflow must be evaluated with the actual duct and bed resistance, including changes during operation.

Airflow function

  • Between the covered odor source and the biofilter distribution space, drawing collected air through the duct and toward the moist treatment bed.
  • A centrifugal fan can develop the pressure required by collection ducts, conditioning sections and the bed. A corrosion-resistant construction may be relevant when the actual gas chemistry and moisture warrant it.

What can change the result

  • Dry media, channeling or uneven distribution reduces contact with the active moist surface.
Operating requirements

Start with the complete air path

Share your layout and the information you already have. Unknown values can be identified before a configuration is selected.

01Collection airflow and bed resistance
02Gas composition, moisture and temperature
03Material compatibility and process controls
LONGWELL fan options

Match the fan to this air path

LONGWELL Anti-corrosion centrifugal family can be evaluated for this duty. A centrifugal fan can develop the pressure required by collection ducts, conditioning sections and the bed. A corrosion-resistant construction may be relevant when the actual gas chemistry and moisture warrant it.

Where it sits

Between the covered odor source and the biofilter distribution space, drawing collected air through the duct and toward the moist treatment bed.

Why consider this configuration

A centrifugal fan can develop the pressure required by collection ducts, conditioning sections and the bed. A corrosion-resistant construction may be relevant when the actual gas chemistry and moisture warrant it.

Check the result in your equipment

Check enclosure capture, flow through the bed and the biological treatment conditions together.
Confirm the selected fan operating point using the complete installed air-path resistance.
Confirm mounting, supply and controls with LONGWELL before integrating the selected assembly.

Discuss your biofilter extraction duty

Send collection airflow and bed resistance, gas composition, moisture and temperature, material compatibility and process controls. Ask LONGWELL to review a suitable configuration, fan curve, drawing and control details. A layout or existing fan model can start the review.

A layout, installation photos or your existing model is enough to start the discussion.