A radon fan pulls from below the slab to reduce the entry force into the building.

In active sub-slab depressurization, a fan connected to suction points lowers pressure beneath the floor and discharges soil gas outdoors. Soil permeability and the connected collection network determine how far the pressure field reaches.

Educational sub-slab principle. Diagnostic testing, fan suitability, discharge placement, alarms, installation and code compliance require a qualified mitigation design. Open video ↗
01 / Application principle

Follow the airflow through the equipment.

01

Entry pressure

Small pressure differences can draw soil gas through cracks and penetrations into a building.

02

Suction point

A pipe connects the aggregate or soil beneath the slab to the active system.

03

Pressure field

The fan lowers pressure around connected sub-slab spaces, subject to soil and slab resistance.

04

Outdoor discharge

Soil gas travels through a sealed exhaust route to an approved outdoor termination.

02 / Fan responsibility

What the fan is responsible for

  • Maintain the required negative pressure field across the connected sub-slab area.
  • Operate continuously against the actual soil, suction-point and pipe resistance.
  • Support monitoring and a safe response when airflow or fan operation is lost.
Air-path check

Why the route matters

  • A single suction point may not communicate through a divided or low-permeability sub-slab area.
  • Leaks, water or condensate can change the pressure path and fan duty.
  • An unsafe discharge or fan location can create a new exposure or service problem.
03 / Prepare the duty

Define these inputs before choosing a fan

01Diagnostic radon measurements and sub-slab communication testing
02Soil or aggregate permeability, slab divisions and penetrations
03Required airflow and suction pressure for the complete pipe network
04Pipe diameter, length, fittings, condensate and outdoor temperature
05Current model-specific fan curve and continuous-duty evidence
06Ingress, leakage, material, sound, alarm and local mitigation approval
04 / Product route

A LONGWELL route to evaluate: inline radon-fan page family candidate

A current LONGWELL official inline-fan page is associated with radon service, but its title and body conflict on model identity, ingress protection and materials. Use it as an application association only. Before selection, require a current consistent datasheet and fan curve, continuous-duty evidence, installed airflow and suction, ingress and leakage review, condensate handling, alarm strategy and local mitigation approval.

05 / Equipment validation

Verify the complete equipment, not the fan in isolation

A qualified mitigation professional verifies the pressure field and post-installation radon level.
Inspect pipe sealing, condensate handling, fan location, discharge and monitoring.
Confirm continuous-duty electrical, environmental, product and local-code requirements.

Bring the diagnostic pressure-field and pipe-network results.

Share the measured suction points, airflow, pressure, environment and approval requirements so LONGWELL can determine whether a suitable configuration is available.