LONGWELL / Ventilation technology

A slim fan still needs a complete path through the elevator cabin.

A cross-flow fan can spread airflow across a wide, shallow opening above or beside a passenger cabin. Its job is air exchange through the openings defined by the elevator design; it does not create cooling without a separate refrigeration system.

Representative cabin-ventilation layout. Intake and outlet positions, airflow, noise and all elevator requirements must be verified for the actual car. Open video ↗
01 / Application principle

Follow the airflow through the equipment.

01

Cabin opening

Air reaches the fan through the intake provided by the car and ceiling design.

02

Cross-flow wheel

The long impeller draws air across its width and feeds a shallow discharge passage.

03

Distribution

The plenum and grille spread the flow into or out of the cabin.

04

Return path

A separate opening completes the exchange route; the fan cannot work against a sealed cabin.

02 / Fan responsibility

What the fan is responsible for

  • Move the required cabin air through the available openings and guards.
  • Fit a broad, shallow packaging envelope where a conventional round fan may not fit.
  • Operate within the elevator controller, sound and maintenance requirements.
Air-path check

Why the route matters

  • A restricted ceiling grille can consume much of the available pressure.
  • An undefined return opening can short-circuit or choke the intended exchange.
  • Mounting vibration or tonal noise can become obvious in a small occupied cabin.
03 / Prepare the duty

Define these inputs before choosing a fan

01Cabin volume, occupancy basis and required airflow
02Exact intake, discharge and return-opening geometry
03Available width, height, depth and service access
04Voltage, speed control, start/stop and alarm interface
05Sound and vibration acceptance method
06Applicable elevator, guarding, flammability and environmental requirements
04 / Product route

A LONGWELL route to evaluate: cross-flow fans

LONGWELL cross-flow fans provide a broad, shallow airflow format that can be evaluated for a cabin route. Start with the actual intake and outlet drawing, then compare the complete fan at the required resistance and check mounting, wiring, guard and acoustic limits.

05 / Equipment validation

Verify the complete equipment, not the fan in isolation

Test airflow with the production grilles, panels and ceiling cavity installed.
Check sound and vibration inside the cabin at the agreed operating states.
Validate electrical, fire, material, service and elevator-system requirements.

Share the real cabin ceiling and opening layout.

Send the available envelope, airflow target, acoustic limit and control interface for a cross-flow fan review.

Send your application requirements →