Longwell AC Axial Fan | Mains-Powered Air Movement

High-Volume Industrial Axial Fans for Condenser, Heat Pump & HVAC Ventilation — 200mm to 900mm

Longwell AC axial fans move large volumes of air at low pressure — straight-line airflow, direct-drive motor, no complicated ductwork needed.

50/60 Hz IP54 Protection Rating Dustproof and Waterproof -40°C to +60°C Corrosion-resistant
LONGWELL AC axial fan

Get a Quote on AC Axial Fans

Send blade diameter, airflow and voltage - an engineer replies within one working day with a matching model.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Types of AC Axial Fans

AC Axial Fan with Grid

AC Axial Fan with Grid

EC Axial Fan with Panel

EC Axial Fan with Panel

DC Axial Fan with Panel

DC Axial Fan with Panel

EC Axial Fan with Grid

EC Axial Fan with Panel

External Rotor Axial Fan

External Rotor Axial Fan

Internal Rotor Axial Fan

Internal Rotor Axial Fan

Get More Recommendation

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Leave your name, email and phone. Longwell can follow up for specs and model selection.

Need direct technical consultation?

Send your requirements & attachments directly to our senior sales engineers at sales@longwellfans.com.

Catalogs & Brochure for AC Axial Fan

Inside these downloadable PDF brochures, you will find precise aerodynamic performance curves (PQ curves), exact dimensional drawings, wiring diagrams, and acoustic data to help you select the optimal airflow solution for your HVAC or industrial project.

What is AC Axial Fan?

An AC axial fan is a type of axial fan where air enters and exits along the same axis as the rotating impeller. The impeller — a set of blades mounted on a central hub — spins inside a cylindrical or square housing. Air is drawn in from one side and pushed straight out the other, with no change in direction.

The motor that drives it runs on alternating current (AC) mains power: typically 115V, 230V single-phase or 380V three-phase. Unlike DC or EC fans, which require an electronic driver or rectifier circuit, an AC axial fan connects directly to line voltage. This makes it the simplest, most cost-effective way to move large volumes of air in fixed-speed applications.

– Airflow is parallel to the motor shaft

– High volume, low to medium static pressure

– Direct-drive — no belts, no pulleys, no gearbox

– Fixed speed by default (step control via tap switching or VFD on three-phase models)

– Induction motor: shaded-pole or permanent split capacitor (PSC)

– No controller required — wire to mains, it runs

Where they make sense:

When you need to move a lot of air through a short path — condenser coil, louvered wall opening, cooling tower fill, transformer radiator — an AC axial fan is usually the right first choice. The design has fewer parts than a centrifugal blower, costs less to manufacture, and tolerates dirt, heat, and moisture better than electronically-driven alternatives.

In the Longwell lineup, AC axial fans span from 25 mm micro-cooling units to 900 mm industrial workhorses, covering the full spectrum of OEM and end-user ventilation requirements.

Send Your Inquiry Now!

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Longwell AC Axial Fan Model Selection

Have your duty point?

See every LONGWELL model whose P-Q curve covers it — margins, noise and power included. No login.

Library: Ø25–1,000 mm, single units up to about 52,000 m³/h — larger duties go straight to an engineer. Prefer to talk it through? Send your specs to an engineer Browse all AC Axial Fan models with curves on the Fan Selector →

Buying from LONGWELL

  • Brand owner since 1990
  • Yuyao, Ningbo
  • 12-month standard warranty, extendable to 18–24 months by project agreement
  • Reply within 1 business day

Certificates you can check

Product certificates cover only the models listed on each document — ask which ones apply to your model. ISO certificates cover management systems, not products. Declaration of Conformity for your model and destination on request.

All document scans and what each covers

Test & release at LONGWELL

Specified and drawn by LONGWELL, built to our drawings by qualified partner factories, inspected and released to LONGWELL standards.

  • Wind tunnel · AMCA 210 method
  • Semi-anechoic room · sound power testing
  • Outgoing sampling to AQL 2.5
  • Test records retained for 5 years

How ordering works

  1. Spec check duty point & drawings
  2. Samples 1–3 days (stock models), fee credited to first order
  3. Validation on your bench
  4. Order T/T 30/70 (first order)
  5. Production & release 15–30 days, partner factory
  6. Shipping & after-sales FOB · CIF · DDP
Full terms, QC and FAQ

High Airflow Performance

CFD-optimized 5-blade steel impeller. Higher volumetric flow at the same wattage — less tip loss, more air through the coil.

Energy-Saving AC Motor

Shaded-pole & PSC motors matched to impeller load curves. Zero standby draw, low inrush. 380V three-phase models accept VFD input.

Low Noise Operation

Factory-balanced to G6.3. Curved blade edges and smooth surfaces cut turbulence noise — lower sound power at blade-pass frequency.

Long Service Life

Sealed dual ball bearings, L10 60,000 h at 60°C. Die-cast aluminum housing, Class F insulation. 1,500 VAC dielectric tested on every unit.

Advanced Blade Design

One-piece molded nylon or steel blades — higher pressure at lower tip speed. UV-resistant composite; stainless steel option for marine & washdown.

Compact & Easy Installation

Standard mounting across the LWAA series — ring flange, wall plate, or cube housing. W-lead or T-terminal, tool-free access, hardware included.

Specifications of Longwell AC Axial Fan

These are the standard build specifications carried by every Longwell AC axial fan in the LWAA product line. Custom values can be engineered for volume OEM projects.

  • Sizes (Diameter of blades): Ranging from 25 mm to 900 mm, with standard sizes like 200mm, 300 mm, 400 mm, 450mm, 630mm, and 710 mm, 800mm, 900mm stock.
  • Operating Voltage Range: 103 VAC to 126 VAC for 115V; 207 VAC to 253 VAC for 230V; 365 VAC to 400 VAC for 380V
  • Motor Type: Equipped with AC motor, BLDC/EC Motors
  • Housing: Durable aluminum die-cast housing that provides strength without added weight.
  • Impeller: Equipped with high-strength iron material
  • Voltage: Designed for 115 VAC, 230 VAC, or 380V operation.
  • Bearing: Available with two ball bearings
  • Termination: Options include W-lead wire or T-terminal type wire.
  • Operating Temperature Range: Ball bearings operate from -20℃ to +70℃; sleeve bearings from -10℃ to +55℃.
  • Life Expectancy: Ball bearings last up to 60,000 hours at 60℃; sleeve bearings up to 20,000 hours at 45℃.
  • Dielectric Strength: 1,500VAC for 1 minute at 50/60Hz.
  • MOQ: 30PCS
Specifications of AC Axial Fan

AC vs. DC vs. EC Axial Fans

Not every cooling or ventilation job calls for the same motor technology. Below is a straight comparison of the three main axial fan drive types — what each one does well, where each one falls short, and which applications they’re built for. If the decision still isn’t clear, our application engineers can size a fan to your exact duty point and walk you through the trade-offs.

Feature

AC Axial Fan

DC Axial Fan

EC Axial Fan

Power Source

AC mains: 115V / 230V / 380V

DC: 12V / 24V / 48V

AC mains (internally rectified to DC)

Motor Type

Induction (shaded-pole, PSC)

Brushless DC (BLDC)

Electronically commutated (BLDC + integrated driver)

Speed Control

Fixed speed. Step control via tap switching or VFD (3-phase).

Voltage or PWM. Wide range, precise.

0–100% via 0–10V, PWM, or Modbus RTU. Built-in controller.

Efficiency

30–50% (motor only; system efficiency higher at duty point)

60–75%

75–90%

Unit Cost

Low. No electronics.

Medium.

High. Integrated driver adds cost.

Installation Complexity

Wire to mains. Done.

Requires DC power supply or battery.

Wire to mains. Set control signal if variable speed needed.

Lifespan (L10)

30,000–60,000 hours

40,000–70,000 hours

60,000–80,000 hours

Noise at Full Speed

Moderate to high

Low to moderate

Lowest

Noise at Reduced Speed

N/A (fixed speed)

Lower

Very low

EMC / EMI

Negligible

Moderate

Requires filtering (integrated on CE/UL units)

Operating Temp Range

−20°C to +70°C (ball bearing)

−10°C to +60°C (electronics-limited)

−20°C to +60°C (electronics-limited)

Resilience to Harsh Environments

High. No electronics, no semiconductors. Handles dirt, moisture, heat.

Low to medium. Electronics need protection.

Medium. Driver board is the weak point.

Best For

Fixed-speed, continuous-duty, high-temp, dirty/wet, cost-sensitive

Battery-powered, mobile, electronics cooling, compact spaces

Variable-speed, energy-regulated, smart building, low-noise mandatory

Example Applications

Condenser, heat pump, cooling tower, transformer, industrial exhaust

Vending machine, server rack, vehicle HVAC, solar-powered ventilation

Data center containment, greenhouse, hospital HVAC, office ventilation

Why Choose Longwell AC Axial Fan?

1. 30+ Years on the Factory Floor

Manufacturing fans and motors since 1990 — not a trading company. We own the lines, the tooling, and the test lab. Custom voltage or modified bracket? The answer comes from an engineer on the floor, not a middleman forwarding emails. Tired of middlemen who can’t answer technical questions?

2. In-House R&D & Testing

ISO 5801 air performance chamber, motor dynamometer, environmental chamber, salt spray cabinet — all on site. Every impeller design goes through CFD simulation before a mold is cut. Prototypes tested to failure so production units don’t fail in the field. No more guessing if the fan will hold up.

3. Full Certification Portfolio

CE, UL/ETL, CCC on standard products. Factory-level: ISO 9001 (quality), ISO 14001 (environmental), BSCI (social compliance). We support RoHS, UKCA, Reach, and customer-specific audit protocols per your market. Need certs for a specific market? We handle it.

4. No MOQ on OEM Development

No MOQ on OEM development. Custom voltage, lead length, connector, or label — we’ll run a trial batch of 50 units for your engineering validation. Production ramp-up after approval. Standard lead time: 90 days from drawing sign-off. Stop fighting suppliers over minimum orders.

5. Factory-Direct, Global Logistics

Factory in China, warehousing partnerships in North America and Europe. Factory pricing with full traceability — no distributor markup. FCL, LCL, air freight, or DDP. All docs — packing list, COO, test reports, certs — provided before the container leaves. Why pay a middleman 30% for forwarding emails?

6. One Supplier, Three Motor Technologies

AC, DC, and EC axial fans under one roof. When your project grows from a fixed-speed AC fan to something needing variable speed or ultra-low noise, you don’t qualify a new vendor. Same quality system, same test standards, one technical contact.

Engineered Solutions for AC Axial Fans

Designed for reliable high-volume airflow across major industrial, HVAC, and refrigeration applications, ensuring robust performance under demanding operational conditions.

Building Ventilation System

Building Ventilation System

Warehouse air exchange, factory ventilation, parking garage CO extraction, workshop fume removal. Axial fans move high volumes through large cross-sections with minimal duct resistance — exactly what open-plan industrial spaces need.

Ventilation fans →
Roof Ventilation System

Roof Ventilation System

Roof-mounted exhaust for heat stratification control. Longwell axial fans operate in vertical orientation with IP54 or better sealing. Rated for continuous outdoor exposure — sun, rain, snow.

Roof fans →
Condenser

Condenser

Air-cooled condensers in refrigeration systems, walk-in coolers, cold rooms, and refrigerated display cases. The LWAA platform delivers the static pressure needed to push air through tight finned-coil packs on condenser units.

Condenser fans →
Evaporator

Evaporator

Forced-air evaporator airflow in cold storage, blast freezers, and processing rooms. Consistent airflow keeps coil temperature stable, reduces frost buildup intervals, and maintains setpoint in high door-traffic environments.

Evaporator fans →
Heat Pump

Heat Pump

Outdoor unit condenser and evaporator airflow for air-source and water-source heat pumps. Sized to overcome coil resistance and discharge grille losses while keeping noise within residential and commercial ordinance limits.

Heat pump fans →
Cooling Tower

Cooling Tower

Forced-draft and induced-draft cooling tower ventilation. LWAA-630 and LWAA-800 models deliver the airflow and pressure head needed for tower fill resistance, drift eliminators, and discharge louvers. Corrosion-resistant options for treated water environments.

Cooling tower fans →

What Our Customers Say after Used

Technical & Sourcing Insights

Q1. What is the difference between an AC axial fan and a centrifugal blower?

An AC axial fan moves air parallel to the motor shaft — straight through, inlet to outlet on the same axis. It produces high airflow at low to medium static pressure. A centrifugal blower turns the airflow 90 degrees — air enters at the center and exits radially. Centrifugal blowers generate higher pressure but lower airflow for the same frame size.

Rule of thumb: if the air path is short and open (through a condenser coil, across a louver, out a wall opening), use an axial fan. If you are pushing air through long ductwork, filters, or tight heat exchangers, use a centrifugal blower.

Longwell makes both. If you’re not sure which one your application needs, send us the airflow (m³/h or CFM) and static pressure (Pa or inH₂O) at your operating point, and we’ll recommend the right fan type and size.

Single-phase AC axial fans are fixed-speed by design — the motor speed is locked to the line frequency (50 or 60 Hz). You can step the speed down using a tap-switching autotransformer or a triac-based speed controller, but the control range is limited and motor efficiency drops off below 60-70% of rated speed.  

Three-phase 380V models can accept a variable frequency drive (VFD) input. This gives you true variable speed control across a wide range without sacrificing motor efficiency. If you need stepless, wide-range speed control, we recommend looking at our EC axial fan series — electronically commutated motors with built-in 0-100% speed control via 0-10V or PWM signal.  

Tell us your speed range requirement and we’ll point you to the right motor platform.

IP54 is the minimum for outdoor use — it protects against dust ingress in harmful quantities and splashing water from any direction. This is the standard rating on most Longwell industrial axial fans.  

For rooftop units exposed to driving rain, or for washdown areas in food processing plants, we recommend IP55 — adds protection against water jets.  

For marine environments, coastal installations, or chemical plant service, specify IP66 and stainless steel blades and fasteners. We have done this configuration for data center condenser yards in the Middle East and offshore platform ventilation in Southeast Asia. 

IP68 (submersion-rated) is available as an engineered-to-order option for specialized applications.

Standard catalog models — 2 to 4 weeks from order confirmation, depending on order volume and current production schedule.  

Custom-engineered variants (modified voltage, blade material, connector, or mounting) — 90 days from drawing approval. This includes tooling modification (if needed), prototype build, in-house testing, and customer sample approval.  

Large OEM blanket orders — lead time and delivery schedule are agreed upon during the contract phase. We build to a rolling forecast and hold safety stock of long-lead components (motor laminations, bearing sets, aluminum housing castings) to buffer against supply chain disruptions.  

For current lead times on a specific model and quantity, contact our sales team with the part number and annual volume estimate.

Yes. We ship evaluation samples — typically 2 to 5 units — for customer testing and approval. Standard catalog models ship from stock within 1 week. Custom variants require tooling setup and prototype build before samples are available (see lead time in FAQ 4).  

Sample policy: sample unit cost is charged at the quoted unit price plus freight. The sample cost is credited against your first production order of 500 units or more.  

All samples ship with a full test report: airflow curve (Pa vs. m³/h), power consumption at rated voltage, noise level (dB(A) at 1 m), vibration grade, and insulation resistance test. What you test in your lab is what you get in production.