Ventilation Fans for Crypto Mining Farms

ASIC miners turn almost all of their electrical power into heat. A room or container full of miners produces a large, constant heat load, and the miners’ own fans need a supply of cool air and a clear path for hot exhaust. If hot air recirculates, hashboards throttle or shut down. Large exhaust fans that remove hot air quickly, with filtered intake air, keep the site running.

LONGWELL supplies high-volume axial exhaust fans, sidewall fans and EC fans for mining farms, mining containers and hosting facilities, through contractors and integrators.

LONGWELL LWAF35-11 axial fan
LONGWELL LWAF35-11 axial fan. The model is selected for the application.

Typical layouts

Site typeAir pathFan choice
Warehouse mining farmCold intake wall → miner racks → enclosed hot aisle → exhaust wall or roofLarge axial or sidewall exhaust fans in the hot-aisle wall
Mining containerFiltered intake on one side, miners in rows, exhaust fans on the opposite sideAxial or EC exhaust fans sized to the container’s power
Small room / home miningDucted exhaust from the miners to outsideInline or mixed-flow duct fans

How to size exhaust fans

1. Start from the power

Nearly all miner power becomes heat. Required airflow (m³/h) ≈ 3.1 × heat load (W) ÷ allowed temperature rise (K) between intake and exhaust.

2. Allow for the miners’ fans

Room or container fans should move at least as much air as the miners exhaust, so hot air does not build up in the hot aisle.

3. Intake and filtration

Give the intake enough area with filters or screens against dust and insects, and keep it away from the exhaust to prevent recirculation.

4. Redundancy and control

Use several fans rather than one, so a single failure does not stop the site. EC fans with 0–10 V or PWM control can follow the temperature, reducing power and noise at night or in winter.

5. Noise

Mining sites are often close to neighbours. Larger, slower fans and acoustic treatment help.

LONGWELL fans for mining sites

  • LWAF35-11 industrial axial fans: 13+ frame sizes from 293 mm to 1,140 mm, up to 61,000 m³/h; heavy-duty carbon-steel casing, copper motor; duct or fixed installation.
  • LWWEXD sidewall exhaust fans: 400–900 mm, with rain deflector and insect screen.
  • AC axial fans: 500, 630 and 800 mm for wall or panel mounting.
  • EC axial fans: 250–450 mm, 230 V, 0–10 V/PWM speed control, for containers and temperature-controlled systems.
  • LWSJG mixed-flow duct fans: 200–800 mm, up to 23,700 m³/h, for ducted exhaust.

Browse: industrial axial fans · EC axial fans · AC axial fans · sidewall exhaust fans
Download: EC axial fan catalogue · AC axial fan catalogue
Related: shipping container ventilation · data centers · containerized power equipment

What to include in your enquiry

  • Site type (warehouse, container, room) and total miner power
  • Layout drawing: intake, racks, hot aisle, exhaust
  • Climate (maximum outdoor temperature, dust)
  • Voltage and phase; speed control wanted
  • Noise limits; number of sites

Send your mining site layout →

FAQ

How much airflow does a mining farm need?

Required airflow (m³/h) ≈ 3.1 × total miner power (W) ÷ allowed temperature rise (K). For example, 100 kW with a 15 K rise needs roughly 20,700 m³/h, before margin.

Exhaust fans or supply fans?

Exhaust from an enclosed hot aisle is most common, because it removes hot air directly and keeps the intake side cool.

Can EC fans reduce running costs?

EC fans can slow down when less cooling is needed, such as at night or in winter, which reduces fan power. Savings depend on the site.

Do you supply fans for mining containers?

Yes. Axial and EC fans are supplied to container builders; send the container power and layout for a selection.