Dust Collection Calculator — CFM, Duct Size, Velocity & Static Pressure

Dust collection fails for one reason: air moving too slowly to carry the chips. This tool gives the CFM for the machines running at once, the duct size that keeps velocity in the 3,500–4,500 fpm transport band, the static pressure of your longest run, and therefore the collector or blower you actually need — not the free-air number on the box.

No signup · Works on mobile · Formulas shown below · Updated 2026-08-24

Dust Collector & Duct Sizing

Duct area = CFM ÷ velocity. Static pressure by Darcy–Weisbach (steel) plus hood, elbows, flex and filter.

CFM
fpm
20 m/s ≈ 4,000 fpm
ft
ft
Flex costs ~3× rigid duct per foot — keep it short.
in. w.g.
Cyclone 1.5–2.5, cartridge filter 0.5–1.5 (loaded), bag 1.0, hood 0.3–0.8.

Results

Engineering estimate for preliminary sizing. Verify against the fan curve, local codes and your system measurements before purchase. Ask a Longwell engineer to check your duty point free of charge.

CFM requirements by machine

MachineCFM (at the port)Port / branch
Table saw (cabinet)3504 in
Table saw (contractor / open base)4504 in
Band saw 14 in3504 in
Band saw 18–24 in5505 in
Jointer 6–8 in3504 in
Jointer 12 in+5505 in
Planer 12–15 in4004 in
Planer 20 in+8006 in
Router table3504 in
Shaper5505 in
Drum sander 16–25 in5505 in
Wide belt sander 37 in12008 in
Disc / belt sander3504 in
Miter / radial arm saw3504 in
Lathe3504 in
CNC router 4×88006 in
Floor sweep3504 in
Downdraft sanding table8006 in
Metal grinder / belt (spark trap)4004 in
Laser cutter fume4004 in
Plasma table downdraft 4×415008 in
Typical values for fine-dust collection (ACGIH Industrial Ventilation and manufacturer data). Older "chip collection" figures are ~30 % lower; use these for health-grade collection.

Design rules

Duct area A = CFM ÷ velocity (fpm) → D = √(4A/π)
Transport velocity wood 3,500–4,000 fpm (18–20 m/s) · metal 4,000–5,000 · fine dust 3,000–3,500 · vertical runs +10 %
Velocity pressure pv = (fpm ÷ 4,005)² in. w.g.
Static pressure = duct friction + 3× flex friction + fittings (K × pv) + hood entry (0.5 pv) + filter/cyclone
Collector select at design CFM and static pressure; free-air ratings overstate delivery by 40–60 %
  • Round down the main duct so velocity stays above transport speed; oversize ducts are the #1 cause of clogged horizontals.
  • Blast gates on every branch; open only the machine in use.
  • Wyes, not tees; long-radius elbows (R ≥ 1.5 D); flex ≤ 6 ft at the tool only.
  • Cyclone first for chip-heavy work — it keeps the filter drop flat and the airflow constant.
  • Grounding: bond metal duct; run a ground wire in plastic duct for wood dust.
  • Blower type: backward-curved material-handling impeller (radial for heavy chips), motor out of the airstream; spark trap for metal.

Frequently Asked Questions

How many CFM do I need for a dust collector?
Size for the largest machine (or the two you run together): 350 CFM for a 4 in port machine (table saw, jointer, band saw), 550 for 5 in (shaper, drum sander), 800 for 6 in (planer 20 in, CNC), 1,200+ for wide belt sanders. Then check the static pressure — a collector must deliver that CFM at 3–6 in. w.g., not in free air.
What duct size for 800 CFM?
At 4,000 fpm transport velocity 800 CFM needs 0.2 ft² → 6 in round duct (5.8 in calculated). Use 6 in mains and 4 in branches to 350 CFM machines.
What velocity should dust collection ducts have?
3,500–4,000 fpm (18–20 m/s) for wood chips and dust, 4,000–5,000 fpm for metal, 3,000–3,500 for fine sanding dust only. Below transport velocity, material drops out in horizontal runs and blocks the duct.
Why does my 2 HP dust collector not pull enough?
Its "1,500 CFM" is a free-air rating. With a 30 ft run, a few elbows, flex hose and a filter you typically have 4–6 in. w.g. of static pressure, at which the same unit delivers 500–800 CFM. Reduce static (shorter, bigger-radius, less flex) or choose a blower rated at pressure.

Link to or Cite This Tool

This calculator is free to reference in articles, forums, specifications and course material. Please credit it with a link:

<a href="https://www.longwellfans.com/resources/dust-collection-cfm-calculator/">Dust Collection CFM & Duct Velocity Calculator</a> by LONGWELL Fans

APA: LONGWELL Fans. (2026). Dust Collection CFM & Duct Velocity Calculator. https://www.longwellfans.com/resources/dust-collection-cfm-calculator/

Embed the calculator on your site

Paste this snippet to show the live calculator on your page (no login, no tracking). Please keep the credit link.

<iframe src="https://www.longwellfans.com/resources/dust-collection-cfm-calculator/?embed=1" width="100%" height="760" style="border:1px solid #e2e8f0;border-radius:12px" loading="lazy" title="Dust Collection CFM & Duct Velocity Calculator by LONGWELL Fans"></iframe>

Related Calculators

Related Guides & Products

Need a fan for this duty point?

Send us the airflow, pressure, voltage and space you have. Longwell engineers select from 3,800+ EC, AC and DC fans and reply within one working day.

← All fan engineering calculators