ebm-papst R3G280 Alternative — LONGWELL LWBE3G-280-EC

Looking for an alternative for ebm-papst R3G280-AF35-71? The LONGWELL LWBE3G-280-EC is the dimensionally interchangeable backward-curved EC equivalent — same mounting, same control protocol, AMCA 210/211 third-party-tested performance — at 40–55% lower landed cost with 15-day delivery vs 14–22 weeks ex-works ebm-papst. R3G is ebm-papst's primary backward-curved centrifugal line; LONGWELL matches or exceeds it across the full size range.

Replaces: ebm-papst R3G280-AF35-71 Frame / size: Ø280 mm Family: R3G → LONGWELL LWBE3G (backward-curved EC) Sample: 1–3 days
Replacing
ebm-papst
R3G280
R3G · EC backward-curved centrifugal · Ø280 mm
With
LONGWELL
LWBE3G-280-EC
Drop-in dimensional match · same control · 15-day delivery

Specification Comparison

Specificationebm-papst R3G280LONGWELL LWBE3G-280-EC
Fan typeEC backward-curved centrifugalEC backward-curved centrifugal
Impeller / frameØ280 mmØ280 mm Drop-in
Airflow rangeup to 2,800 m³/hup to 2,800 m³/h
Static pressure (max)up to 800 Paup to 800 Pa
Power class≈425 W (LW ≈225 W at duty)≈425 W (LW ≈225 W at duty)
Wire-to-air η peak (AMCA 210)89%89%
Noise floor (Lw)71 dB(A)72 dB(A)
Voltage200–277 V200–277 V
Control input0–10 V / PWM / Modbus / EC-Control0–10 V / PWM / Modbus RTU / Modbus TCP Compatible
CertificationsCE · UL · VDE · EACCE · UL · cUL · TÜV · EAC · RoHS · REACH
Sample lead time4–10 weeks1–3 days
Series lead time (≤500 units)14–22 weeks15–30 days
Landed cost index (LONGWELL = 100)175–200100 (baseline)

Engineered match verified against ebm-papst R3G280-AF35-71 in LONGWELL's cross-brand model library (record: LWBE3G280-092PS-03). The LWBE3G280-092PS-03 match is an energy-saving selection — it holds the CRAH duty point at materially lower input power.

Why Engineers Switch from R3G280 to LWBE3G-280-EC

4–8× Faster Delivery

15–30 days
vs 14–22 weeks ex-works for ebm-papst in 2026 (active allocation). Sample units 1–3 days from stock.

40–55% Lower Landed Cost

−40 to −55%
per unit at equivalent spec. On a multi-unit AHU / fan-grid program the CapEx delta scales fast.

−48% Input Power at CRAH Duty

225 W
vs 425 W for the original at the same 280 mm CRAH cooling duty point — directly lowering data-center fan PUE.

Drop-In Compatibility Details

Mechanical match

The LONGWELL LWBE3G-280-EC matches the ebm-papst R3G280 mounting pattern (plenum-fan footprint, inlet ring diameter, motor shaft height, terminal-box position) within ±0.5 mm tolerance. Drop-in retrofit requires no AHU rework, no plate modification, and no plenum hole resizing.

Electrical & control match

The LWBE3G-280-EC accepts the same 0–10 V analog speed reference, PWM (1 kHz), and Modbus RTU (RS485) control as the ebm-papst R3G280. LONGWELL provides a free Modbus register-map cross-reference for BMS integration; ebm-papst EC-Control / GeneSys bus is bridged with a free MODBUS gateway — no BMS reprogramming required.

Performance match

The PQ curve of the LONGWELL LWBE3G-280-EC sits within 2–3% of the ebm-papst R3G280 across the operating envelope (third-party AMCA 210/211 testing at TÜV / Intertek). Wire-to-air efficiency at BEP is 89% vs 89% — backward-curved EC parity. The LWBE3G280-092PS-03 match is an energy-saving selection — it holds the CRAH duty point at materially lower input power.

Typical Applications

The LONGWELL LWBE3G-280-EC is widely deployed across data-center CRAC/CRAH, server-rack cooling and RDHx modules. Common application categories include:

  • Data-center CRAC / CRAH
  • Server-rack & RDHx cooling
  • FFU modules

The 280 mm size is the workhorse of AI data-center rear-door and in-row cooling.

FAQ

Is LONGWELL LWBE3G-280-EC a true drop-in replacement for ebm-papst R3G280?
Yes. The LWBE3G-280-EC matches the R3G280 dimensionally (mounting hole pattern, inlet ring diameter, motor shaft height) within ±0.5 mm, accepts the same 0–10 V / PWM / Modbus RTU control, and runs from the same 200–277 V supply. Installation is identical to a same-brand replacement. Verified library record: LWBE3G280-092PS-03.
How does LWBE3G-280-EC compare on efficiency to R3G280?
ebm-papst R3G280 delivers ~89% peak wire-to-air efficiency. LONGWELL LWBE3G-280-EC measures ~89% in AMCA 210/211 third-party testing — backward-curved EC parity. At CRAH duty the LW runs at 225 W vs 425 W for the original — directly lowering data-center fan PUE.
What's the 2026 lead-time difference?
As of May 2026 ebm-papst R3G280 runs 14–22 weeks ex-works under allocation. LONGWELL LWBE3G-280-EC ships in 15–30 days for orders up to 500 units, 6–10 weeks for 1,000+ unit OEM programs, and samples in 1–3 days from stocked Ø280 mm inventory.
What's the cost delta?
At equivalent spec (same Ø, airflow/Pa, IP, control), LONGWELL LWBE3G-280-EC typically lands 40–55% below ebm-papst R3G280 ex-works. Final pricing depends on quantity, voltage, IP and control options.
Is R3G the same as K3G?
No. R3G is ebm-papst's standard backward-curved centrifugal line; K3G (RadiCal) is the aerodynamically-optimised variant. They share frame sizes but differ in wheel design and part number. This page maps the R3G280 specifically; for the RadiCal equivalent see the K3G280 page in the alternatives index.

Replace your R3G280 in 5 days

Send a quick request — model + quantity + delivery address. Sample unit ships in 1–3 days for field validation. Series production at 15-day lead time after PO.

Request Sample View Full Cross-Reference Table
Official Product Page
Browse the full Backward-Curved Centrifugal EC Fans range on longwellfans.com — request a quote on LWBE3G-280-EC directly.
View on longwellfans.com →