Engineering Reference Case Profile · Battery Gigafactory ATEX Dust Collection

Battery Cathode Powder Dust Collection · Gigafactory ATEX IIIC

A composite reference case based on representative battery gigafactory cathode/anode dust collection deployments — supplying ATEX II 3D Ex tc T125°C IIIC certified plug fans + high-pressure CDU fans for cathode (NMC) powder handling with 3.2 kPa static for dense cartridge filter face, ramping to 80,000 fans/year across gigafactory build-out.

Project size: Gigafactory · cathode workshop · 12,000 ATEX plug + 5,000 high-pressure CDU per year Reference period: Composite reference · 2025–2026 deployment pattern Geography: Asia-Pacific battery gigafactory segment
About this case profile: This is an anonymized composite reference case based on representative LONGWELL platform deployments in the Industrial Dust · Battery Cathode Workshop segment. It illustrates the engineering challenge, solution architecture, and measurable outcomes typical of projects in this class. Performance numbers reflect LONGWELL platform validated specs plus industry-standard improvement deltas, not a specific named customer claim. Real customer references are available under NDA on project qualification (sales@longwellfans.com).

1 · Challenge

  • NMC cathode powder dust = combustible electrically-conductive (IIIC) — most aggressive ATEX dust group.
  • ATEX II 3D Ex tc T125°C IIIC required for collector interior fans (zone 21).
  • Modern dense cartridge filter media requires 1,500–3,000 Pa fan static pressure — exceeds standard plug fan envelope (1,800 Pa).
  • Gigafactory ramp: 12,000 ATEX plug fans + 5,000 high-pressure CDU fans per year, sustained through 2030.
  • OSHA NFPA 652 + EU CBAM-aligned emissions documentation per shipment.

2 · Solution Architecture

Per gigafactory cathode workshop: 12,000 LWBE3G-ATEX-IIIC in cartridge dust collectors (zone 21 interior). 5,000 LWHV-ATEX-450-HP on dense cartridge filter face for cathode dust capture at 3.2 kPa static. 3,000 LWAE3G-ATEX-630 for workspace clear-air ventilation. All units include IEC 60079-31 ATEX certificate per shipment + NFPA 652 compliance declaration.

Bill of materials

LONGWELL SKUTypeQtyKey spec
LWBE3G-ATEX-IIICATEX EC plug fan12,000 units/yrØ355–Ø560 mm, II 3D Ex tc T125°C IIIC, electrically grounded impeller + shaft per IEC 60079-31, 87% η peak
LWHV-ATEX-450-HPATEX high-pressure plug fan5,000 units/yrØ450 mm, 3.2 kPa static, II 3D Ex tc T125°C IIIC, anti-static + spark-resistant housing
LWAE3G-ATEX-630ATEX workspace ventilation axial3,000 units/yrØ630 mm, ATEX II 3D Ex tc T125°C IIIC for cathode-workspace clear-air ventilation

3 · Measured Outcomes

ATEX certification scope
II 3D Ex tc T125°C IIIC
full combustible-dust IIIC
Static pressure capability
3.2 kPa
LWHV-ATEX-450 max
Annual fan supply
20,000 units
ATEX + high-pressure + workspace
ATEX-related incidents (2-yr)
0
in field service
Lead time first batch
6 weeks
vs 16–22 wk European ATEX
CapEx delta vs ebm-papst RadiPac ATEX
−45%
at gigafactory volume

4 · Implementation Timeline

Week 0Gigafactory PO for 20,000-unit annual program
Week 1–5ATEX recertification + tooling for IIIC scope
Week 6First 1,500-unit batch ships
Month 3Series cadence at 1,700 units/month
Year 1Cumulative 20,000 fans deployed across cathode workshop
Year 2+Steady 1,700 units/month + commissioning at next gigafactory phase

5 · Engineering Lessons

  1. ATEX dust group IIIC (combustible electrically-conductive) is more aggressive than IIIB (grain) or IIIA (sugar). Battery cathode dust requires full IIIC scope — IIIB-only certification is insufficient.
  2. 3.2 kPa static pressure capability (LWHV-ATEX vs standard plug at 1.8 kPa max) was the binding spec for modern dense cartridge filter face. Standard plug fans starve below design CFM in this duty.
  3. ATEX certificate per shipment (not as one-time type test) is mandatory for permit-issuing authorities. Compliance statement attached per bill of lading.
  4. Workspace clear-air ventilation (LWAE3G-ATEX-630) in zone 22 (occasional dust) is often forgotten in dust-collector OEM spec — but required for OSHA compliance at the workplace.
  5. Sustained 1,700 fans/month cadence required dedicated ATEX production line at Yuyao + Hai Phong — competitor European brands cannot match this volume.

Get a sized BOM for your project

Send your application duty point (CFM, Pa, ambient T, IP, certification scope). LONGWELL Engineering returns a sized BOM, AMCA test data, and reference deployment schedule within 24 hours.

📧 Request Sized BOM Browse All 10 Case Profiles