Nicotra Gebhardt RDP 355 Alternative — LONGWELL LWBE3G-355-EC

Looking for an alternative for Nicotra Gebhardt RDP 355? The LONGWELL LWBE3G-355-EC is the dimensionally interchangeable equivalent — same mounting, same control protocol, AMCA 210/211 third-party-tested performance — at 40–55% lower landed cost with 15-day delivery vs 10–14 weeks ex-works Nicotra Gebhardt. Widely deployed across Cleanroom FFU, AHRI-cert AHU, pharma cleanroom.

Replaces: Nicotra Gebhardt RDP 355 Diameter: Ø355 mm Family: RDP series → LONGWELL LWBE3G / LWAE3G / LWHV / LWFC Sample: 1–3 days
Replacing
Nicotra Gebhardt
RDP 355
RDP series · EC plug fan · Ø355 mm
With
LONGWELL
LWBE3G-355-EC
Drop-in dimensional match · Same control · 15-day delivery

Specification Comparison

SpecificationNicotra Gebhardt RDP 355LONGWELL LWBE3G-355-EC
Fan typeEC plug fanEC plug fan
Impeller diameterØ355 mmØ355 mm Drop-in
Airflow range800–4,500 m³/h800–4,500 m³/h
Static pressure (max)1200 Pa1200 Pa
Motor power (max)950 W950 W
Wire-to-air η peak (AMCA 210)89%87%
Noise floor (Lw)68 dB(A)71 dB(A)
Voltage380–480 V 3Φ380–480 V 3Φ
Control input0–10 V / PWM / Modbus / EC-Control0–10 V / PWM / Modbus RTU / Modbus TCP Compatible
IP ratingIP54 / IP55IP54 std · IP55 / IP67 option
CertificationsCE · UL · VDE · EACCE · UL · cUL · TÜV · ATEX · VDE · EAC · RoHS · REACH
Sample lead time4–10 weeks1–3 days
Series lead time (≤500 units)10–14 weeks15–30 days
Landed cost index (LONGWELL = 100)175–200100 (baseline)

Engineered match verified against Nicotra Gebhardt RDP 355 in LONGWELL's cross-brand model library. The LWBE3G-355-EC is a dimensional drop-in with the same 0–10 V / PWM / Modbus control interface and AMCA 210/211 third-party-tested performance across the full operating envelope.

Why Engineers Switch from RDP 355 to LWBE3G-355-EC

4–8× Faster Delivery

15–30 days
vs 10–14 weeks ex-works for Nicotra Gebhardt in 2026 (active allocation). Sample units 1–3 days from stock vs 4–10 weeks.

40–55% Lower Landed Cost

−€600 to −€2,400
per unit at equivalent spec, depending on size and quantity. On a 50-unit FanGrid retrofit, typical CapEx delta is €30k–€120k.

True Drop-In Compatibility

±0.5 mm
mounting hole tolerance + identical control protocol. Installation time same as same-brand replacement.

Drop-In Compatibility Details

Mechanical match

The LONGWELL LWBE3G-355-EC matches the Nicotra Gebhardt RDP 355 mounting pattern (M-mount, ISO 9001 plenum-fan footprint) within ±0.5 mm tolerance. Inlet ring diameter, motor shaft height, and electrical termination box position are identical. Drop-in retrofit requires no AHU rework, no plate modification, and no plenum hole resizing.

Electrical & control match

The LWBE3G-355-EC accepts the same 0–10 V analog speed reference, PWM (1 kHz), and Modbus RTU (RS485) control signals as Nicotra Gebhardt RDP 355. Default Modbus register map is compatible with the Nicotra Gebhardt ecosystem; LONGWELL provides a free Modbus map cross-reference for BMS integration. Nicotra Gebhardt-specific proprietary protocols (EC-Control bus / ZA-control) are bridged via a free MODBUS gateway available from LONGWELL Engineering — no BMS reprogramming required.

Performance match

The PQ curve of LONGWELL LWBE3G-355-EC sits within 2–3% of the Nicotra Gebhardt RDP 355 curve across the full operating envelope (verified by third-party AMCA 210/211 testing at TÜV and Intertek labs). Wire-to-air efficiency at BEP is 87% vs 89% for Nicotra Gebhardt (2 pp delta at peak). In typical part-load HVAC duty, the gap narrows to within 1 pp.

Typical Applications

The LWBE3G-355-EC is widely deployed across Cleanroom FFU, AHRI-cert AHU, pharma cleanroom. Common application categories include:

  • Cleanroom FFU
  • AHRI-certified AHU
  • Pharma cleanroom

Particularly suited for cleanroom FFU and AHRI-certified AHU OEM specifications.

FAQ

Is LONGWELL LWBE3G-355-EC a true drop-in replacement for Nicotra Gebhardt RDP 355?
Yes. The LWBE3G-355-EC matches the RDP 355 dimensionally (mounting hole pattern, inlet ring diameter, motor shaft height) within ±0.5 mm tolerance, accepts the same 0–10 V analog / PWM / Modbus RTU control signals, and operates from the same 380–480 V 3Φ supply. Installation time and AHU integration are identical to a same-brand replacement.
How does LWBE3G-355-EC compare on efficiency to RDP 355?
Nicotra Gebhardt RDP 355 delivers 89% peak wire-to-air efficiency at BEP. LONGWELL LWBE3G-355-EC measures 87% in AMCA 210/211 third-party testing — a 2 pp difference at peak. In typical part-load HVAC duty (30–80% of design airflow), the gap narrows to within 1 pp because both platforms hold flat η curves across their operating range.
What's the 2026 lead time difference?
As of May 2026: Nicotra Gebhardt RDP 355 requires 10–14 weeks ex-works due to ongoing allocation. LONGWELL LWBE3G-355-EC ships in 15–30 days for orders up to 500 units and 6–10 weeks for 1,000+ unit OEM programs. Sample units ship in 1–3 days from stocked Ø355 mm inventory.
What's the cost delta?
At equivalent specification (same Ø, same airflow/Pa, same IP, same control), LONGWELL LWBE3G-355-EC typically lands at 40–55% below Nicotra Gebhardt RDP 355 ex-works pricing. Final pricing depends on quantity, voltage, IP rating, and control protocol options.
What applications is LWBE3G-355-EC typically used for?
LWBE3G-355-EC is widely deployed across Cleanroom FFU, AHRI-cert AHU, pharma cleanroom. Particularly suited for cleanroom FFU and AHRI-certified AHU OEM specifications.

Replace your RDP 355 in 5 days

Send a quick request — model + quantity + delivery address. Sample unit ships in 1–3 days for field validation. Series production at 15-day lead time after PO.

Request Sample View Full Cross-Reference Table
Official Product Page
Browse the full Backward-Curved Centrifugal EC Fans range on longwellfans.com — request a quote on LWBE3G-355-EC directly.
View on longwellfans.com →
Nicotra Gebhardt® is a trademark of its owner. LONGWELL is an independent manufacturer and is not affiliated with, endorsed by, or sponsored by Nicotra Gebhardt. This page is published as engineering reference based on public datasheets.