Industrial Drying, Heat Treatment and Ovens · High-Temperature Duty, Bearings and Second-Source Qualification
Compiled from LONGWELL’s real correspondence with heat-treatment and semiconductor/PV furnace builders, textile flash-dryer OEMs and drying-equipment developers in China, Germany, the USA and France. Three things decide these programmes: the fan has to survive continuous radiant heat, the buyer is almost always qualifying a second source against an incumbent European fan, and the qualification is won on documents as much as on the sample.
1 · Challenge
- Radiant heat kills sleeve bearings. On a quartz flash-dryer, the previous fan used sleeve bearings; continuous radiant heat caused oil migration and noise. The fix is a double ball bearing motor, decided at selection rather than after the first failure.
- Second-source qualification is judged on the datasheet. Industrial equipment buyers evaluating an alternative to an incumbent European fan require the full pack — P–Q curve, dimensions, wiring, protection functions — delivered with the sample, not after it.
- Diameter is not the selection. A 250 mm frame at 240 W does not replace a 250 mm frame at 500 W. Matching rated power and speed matters more than matching the wheel diameter.
- Closed-loop control is normal. PLC-driven dryers need 0–10 V speed control plus a tachometer / FG output for closed-loop monitoring — a detail that is easy to leave out of a first quotation and expensive to retrofit into a harness.
- Voltage variants are a trap. 115 V and 220 V versions of the same cross-flow series look identical; one mis-shipped sample cost a project cycle.
- Boundaries have to be drawn. Customers sometimes ask for 5–8 kW heating elements to be integrated into the fan. That is a system split, not a fan feature.
2 · Solution architecture
Selections supplied into drying, heat treatment and ovens
| Model | Ratings | Control / construction | Application |
|---|---|---|---|
| 500 W-class EC backward-curved (250 mm frame) | 230 VAC (200–270 V), ≈3,740 rpm, targeting 1,355 m³/h @ 733 Pa | 0–10 V / PWM, FG feedback, soft start, stall protection, constant-power control at high pressure; IP44/IP54 | Semiconductor and PV heat-treatment equipment |
| LWBE250-AO | EC backward-curved, 250 mm | CE certified (LVD and EMC) | Furnace and heat-treatment equipment |
| LWCA090-500 | 220 V, 50/60 Hz, 1.2 A, 250 W, 2,500 rpm, 1,400 m³/h, 73 dB(A) | −20 °C to +70 °C, insulation B/F/H, ball or sleeve bearing | Furnace and oven air circulation |
| LWCD-401055MN-06 | 24 V DC, 0.3 A, 2,000 rpm, 311 m³/h | 0–10 V from PLC (red +24 V, black −24 V, white signal), tacho output available | Dryer air path |
| LWCD-601100MN-06 | 24 V DC, 1.3 A, 1,800 rpm, 857 m³/h | 0–10 V from PLC with added tachometer lead | Dryer air path, closed-loop monitored |
| LWCA-06018D23B | 220 VAC cross-flow, 250–300 CFM band | Double ball bearing recommended for radiant heat | Quartz flash-dryer for textile printing |
| 110 V cross-flow with heater module | 110 V, 50/60 Hz, 160 m³/h | UL certification documents supplied | Sanitising / drying terminal equipment |
3 · Verified figures
Fan performance figures are quoted from LONGWELL controlled datasheets and product nameplates and are tested per AMCA 210/211 methods; third-party reports available on request. EC versus AC energy saving is approximately 30%, higher under strongly varying load — confirm against your own load profile. Final selection must be confirmed against the actual duty point (airflow, static pressure, ambient temperature, certification scope) of your machine.
4 · How these programmes run
5 · Engineering lessons carried forward
- Match rated power and speed, not wheel diameter. A 240 W fan in a 250 mm frame will not replace a 500 W fan in a 250 mm frame, and finding that out in the customer’s machine costs a qualification cycle.
- Specify ball bearings where radiant heat is continuous. Sleeve bearings in front of quartz heaters migrate oil and become noisy; raise this at selection rather than treating it as a warranty issue later.
- For second-source qualification, the datasheet is part of the sample. Curve, dimensions, wiring and protection functions have to arrive together, or the sample sits in the customer’s queue waiting for paperwork.
- Ask whether a tachometer or FG output is needed. PLC-controlled dryers frequently close the loop on fan speed, and adding the lead after the harness is designed is far more expensive than including it.
- Where the customer has a local engineering site, test there. In-country machine testing with data reported to head office removed weeks of sample shipping and time-zone delay from one German programme.
- Draw the system boundary early. Integrating a 5–8 kW heating element is not a fan-manufacturing function; proposing an external heater module keeps the project moving instead of stalling on an impossible request.
- Enforce a voltage and nameplate check before despatch on any series that exists in both 115 V and 220 V.
6 · Project evidence
Every item below is a real project thread from LONGWELL’s own correspondence. Each carries an anonymised case reference, the counterparty described by industry and buying role only, an evidence grade, the actual dates from first contact to close, the length of the email thread and, where an invoice is on file, the order value band. Customer names, domains, brand artwork, prices and commercial terms are withheld — including from the photographs. Evidence grade A means controlled documents or test reports are on file for that thread; grade B means a structured enquiry and specification are on file. Order value bands are read from the proforma or commercial invoice held on file and rounded to a band, in the currency as invoiced; many threads on this page are sampling or qualification stages, where the recorded value is a sample order rather than the series volume. Unit prices are never published.
500 W-class EC second source for heat-treatment equipment
Case ref HTE-CN-01 · Sampling · China
Foreign-invested heat treatment and semiconductor/PV thermal equipment manufacturer — R&D and procurement team seeking a domestic second source for an incumbent European fan
First contact 30 Dec 2020 → sample delivered for qualification 29 Jan 2021 (30 days) · 32 emails
- Target: 230 VAC (200–270 V), 500 W class at ≈3,740 rpm, reaching or approaching 1,355 m³/h at 733 Pa, IP54, with 0–10 V/PWM control, FG feedback and constant-power control at high pressure.
- The customer’s own first pick — a 240 W fan in the same 250 mm frame — was short on both power and pressure. Engineering moved to a higher-power, higher-speed EC platform, strengthened the impeller and balance, and matched the P–Q curve to the incumbent.
- A high-power 250 mm EC sample was built in 7–10 days and delivered with the full qualification pack; cross-flow specifications were supplied in parallel for the rest of the machine.
PLC-controlled dryer with closed-loop speed feedback
Case ref DRY-US-01 · Sampling · United States
Energy and equipment technology developer — new dryer and thermal control equipment design
First contact 14 Sep 2024 → custom tacho variant agreed 13 Aug 2025 (333 days) · 27 emails · Recorded order value: under US$5k
- LWCD-401055MN-06 (24 V DC, 0.3 A, 2,000 rpm, 311 m³/h) and LWCD-601100MN-06 (24 V DC, 1.3 A, 1,800 rpm, 857 m³/h), driven from the customer’s PLC over 0–10 V.
- Standard 0–10 V wiring was defined explicitly (red DC24 V+, black DC24 V−, white signal), and after testing a tachometer output lead was added to LWCD-601100MN-06 for closed-loop monitoring.
- The customer’s initial request to integrate a 5–8 kW heating element inside the fan was answered by splitting it out as an external heater module — outside a fan manufacturer’s technical boundary.
Semiconductor / PV furnace builder — tested locally, approved in Germany
Case ref EQP-DE-01 · Order won · Germany
Semiconductor and solar PV high-temperature process equipment manufacturer, headquartered in Germany with R&D and production in China
First contact 11 Nov 2020 → order closed 10 Dec 2020 (29 days) · 25 emails · Recorded order value: under US$5k
- LWCA090-500 AC shaded-pole cross-flow (220 V, 50/60 Hz, 1.2 A, 250 W, 2,500 rpm, 1,400 m³/h, 73 dB(A), −20 °C to +70 °C, insulation B/F/H, ball or sleeve bearing) and LWBE250-AO EC backward-curved, both CE certified.
- Rather than shipping samples to Germany, samples went to the customer’s own Kunshan plant for testing in the actual machine, with the data reported back to head office for approval — cutting the verification cycle substantially.
- The CE certificate below covers the LWBE250-AO to LWBE450-AO range against the Low Voltage Directive.
Quartz flash-dryer — bearing upgrade after field noise
Case ref TEX-US-01 · Sampling · United States
Textile printing equipment OEM — quartz infrared flash-dryers and printing heat equipment; technical decision taken at CEO / chief engineer level
First contact 30 Sep 2018 → revised sample cycle closed 9 Nov 2019 (405 days) · 17 emails
- Duty: 275–300 CFM (7.79–8.50 m³/min), 250 CFM minimum, at 220 VAC, working alongside a 14,400 W three-phase quartz halogen system that flash-dries ink in 1.5–3 seconds, circulating air through a stainless mesh filter.
- A 115 VAC sample had been shipped in error against a 220 VAC requirement, costing a project cycle; the correct 220 VAC LWCA-06018D23B was reissued and a mandatory voltage/nameplate check introduced before despatch.
- The customer’s existing sleeve-bearing motor produced noise under continuous radiant heat; the recommendation was a double ball bearing motor for this duty.
110 V UL-certified cross-flow with heater module
Case ref OTH-FR-01 · Sampling · France
Sanitising and drying equipment manufacturer — footwear and garment disinfection/drying terminals; technical and procurement lead
First contact 15 Apr 2021 → samples agreed 29 Jun 2021 (75 days) · 13 emails
- Tangential fan at 110 V 50/60 Hz delivering 160 m³/h, with UL certification required and a matched warm element.
- A matching 110 V selection was made to the customer’s internal space envelope, UL documentation supplied to shorten the approval cycle, and six sample sets built for testing.

Fan performance figures are quoted from LONGWELL controlled datasheets and product nameplates and are tested per AMCA 210/211 methods; third-party reports available on request. EC versus AC energy saving is approximately 30%, higher under strongly varying load — confirm against your own load profile. Final selection must be confirmed against the actual duty point (airflow, static pressure, ambient temperature, certification scope) of your machine.