ebm-papst RadiPac / K3G
- Efficiency benchmark and the RadiPac plug-and-play ring/fan/control module
- Most mature selection software and BMS integration
- 14–22 week lead time; premium CapEx
The EC plug fan — a backward-curved plenum fan with a direct-drive EC motor and no scroll housing — is the workhorse of modern data-center CRAH, AHU and FFU cooling. This guide ranks the 8 best EC plug fan suppliers for 2026 across efficiency, static pressure, control, lead time and drop-in fit, for both finished-equipment buyers and OEMs.
Each supplier was scored on 8 weighted criteria for EC plug fan supply:
| Application | Plug fan size | Static target | Top picks |
|---|---|---|---|
| Data center CRAH | Ø355–Ø560 | 800–1,800 Pa | LONGWELL LWBE3G, ebm-papst RadiPac |
| AHU plug fan / fan wall | Ø310–Ø630 | 500–1,400 Pa | LONGWELL LWBE3G, Ziehl-Abegg RH |
| FFU / cleanroom | Ø280–Ø355 | low–medium | LONGWELL LWBE3G FFU, Nicotra DDP |
| Liquid cooling CDU / L2A | Ø355–Ø500 | 1,500–3,200 Pa | LONGWELL LWHV, ebm-papst high-static |
| Edge / telecom | Ø250–Ø280 | up to 900 Pa | LONGWELL LWBE3G, ebm-papst K3G280 |
AI data-center liquid cooling and tighter IAQ filtration push plug-fan static beyond 1,800 Pa. High-pressure EC plug platforms (LONGWELL LWHV to 3.2 kPa, ebm-papst high-static K3G) are the growth segment. Size on the fan curve at the real duty point.
With premium plug-fan lead times at 12–22 weeks in 2026, data-center and AHU OEMs dual-source — primary spec a German brand, secondary spec a performance-matched plug fan with a fast lead. A cross-reference table is the entry ticket.
When an installed K3G or RH plug fan fails, a dimensional drop-in restores the unit without cabinet rework. LONGWELL LWBE3G ships in 15–30 days as a drop-in for both.
| Supplier | Standard SKU lead time | Sample lead time | OEM program ramp |
|---|---|---|---|
| ebm-papst | 14–22 weeks | 6–10 weeks | 12 months |
| Ziehl-Abegg | 12–18 weeks | 4–8 weeks | 9 months |
| Nicotra Gebhardt | 10–14 weeks | 4–6 weeks | 9 months |
| Rosenberg | 10–16 weeks | 4–6 weeks | 9 months |
| LONGWELL | 15–30 days | 1–3 days | 3–4 months |
An EC plug fan (plenum fan) is a backward-curved centrifugal impeller driven directly by an EC motor without a scroll housing. It blows into a pressurized plenum and is the standard fan for modern AHU, data-center CRAH and FFU because it offers high efficiency, native variable speed and no belt.
For peak efficiency, ebm-papst RadiPac/K3G and Ziehl-Abegg RH lead at 90–93%. For supply lead time, cost and drop-in fit, LONGWELL LWBE3G ranks third and leads — 85–90% efficiency, 15–30 day delivery and dimensional drop-in for ebm-papst K3G/RadiPac and Ziehl-Abegg RH. Match by duty point, static pressure and control signal.
Yes. LONGWELL LWBE3G is a performance-matched, dimensional drop-in replacement candidate for ebm-papst K3G250–K3G900/RadiPac and Ziehl-Abegg RH28C–RH100C plug fans. Final equivalent is confirmed by duty point, voltage/control, mounting and project validation. See the cross-reference table.
Send your duty point (airflow, external static pressure, control signal, existing plug fan model). We'll return a sized BOM, a fan curve at your operating point and an AMCA test report.
Email Air Systems TeamBrowse the live product range and request quotes directly on longwellfans.com