ebm-papst W3G450 Alternative — LONGWELL LWAE3G-450-EC
Looking for an alternative for ebm-papst W3G450-EN07-14? The LONGWELL LWAE3G-450-EC is the dimensionally interchangeable equivalent — same mounting, same control protocol, AMCA 210/211 third-party-tested performance — at 40–55% lower landed cost with 15-day delivery vs 14–22 weeks ex-works ebm-papst. Widely deployed across Commercial outdoor condenser, large rooftop AHU, industrial cooling tower.
W3G450
LWAE3G-450-EC
Specification Comparison
| Specification | ebm-papst W3G450 | LONGWELL LWAE3G-450-EC |
|---|---|---|
| Fan type | EC axial fan | EC axial fan |
| Impeller diameter | Ø450 mm | Ø450 mm Drop-in |
| Airflow range | 2,500–8,500 m³/h | 2,500–8,500 m³/h |
| Static pressure (max) | 380 Pa | 380 Pa |
| Motor power (max) | 1,200 W | 1,200 W |
| Wire-to-air η peak (AMCA 210) | 65% | 63% |
| Noise floor (Lw) | 71 dB(A) | 73 dB(A) |
| Voltage | 200–240 V 1Φ | 200–240 V 1Φ |
| Control input | 0–10 V / PWM / Modbus / EC-Control | 0–10 V / PWM / Modbus RTU / Modbus TCP Compatible |
| IP rating | IP54 / IP55 | IP54 std · IP55 / IP67 option |
| Certifications | CE · UL · VDE · EAC | CE · UL · cUL · TÜV · ATEX · VDE · EAC · RoHS · REACH |
| Sample lead time | 4–10 weeks | 1–3 days |
| Series lead time (≤500 units) | 14–22 weeks | 15–30 days |
| Landed cost index (LONGWELL = 100) | 175–200 | 100 (baseline) |
Why Engineers Switch from W3G450 to LWAE3G-450-EC
4–8× Faster Delivery
40–55% Lower Landed Cost
True Drop-In Compatibility
Drop-In Compatibility Details
Mechanical match
The LONGWELL LWAE3G-450-EC matches the ebm-papst W3G450 mounting pattern (M-mount, ISO 9001 plenum-fan footprint) within ±0.5 mm tolerance. Inlet ring diameter, motor shaft height, and electrical termination box position are identical. Drop-in retrofit requires no AHU rework, no plate modification, and no plenum hole resizing.
Electrical & control match
The LWAE3G-450-EC accepts the same 0–10 V analog speed reference, PWM (1 kHz), and Modbus RTU (RS485) control signals as ebm-papst W3G450. Default Modbus register map is compatible with the ebm-papst ecosystem; LONGWELL provides a free Modbus map cross-reference for BMS integration. ebm-papst-specific proprietary protocols (EC-Control bus / ZA-control) are bridged via a free MODBUS gateway available from LONGWELL Engineering — no BMS reprogramming required.
Performance match
The PQ curve of LONGWELL LWAE3G-450-EC sits within 2–3% of the ebm-papst W3G450 curve across the full operating envelope (verified by third-party AMCA 210/211 testing at TÜV and Intertek labs). Wire-to-air efficiency at BEP is 63% vs 65% for ebm-papst (2 pp delta at peak). In typical part-load HVAC duty, the gap narrows to within 1 pp.
Typical Applications
The LWAE3G-450-EC is widely deployed across Commercial outdoor condenser, large rooftop AHU, industrial cooling tower. Common application categories include:
- Outdoor condenser
- Rooftop AHU
- Cooling tower
- Large free cooling
Particularly suited for commercial rooftop AHU and industrial cooling tower ventilation.
FAQ
Is LONGWELL LWAE3G-450-EC a true drop-in replacement for ebm-papst W3G450?
How does LWAE3G-450-EC compare on efficiency to W3G450?
What's the 2026 lead time difference?
What's the cost delta?
What applications is LWAE3G-450-EC typically used for?
Replace your W3G450 in 5 days
Send a quick request — model + quantity + delivery address. Sample unit ships in 1–3 days for field validation. Series production at 15-day lead time after PO.
Request Sample View Full Cross-Reference Table