Leave your requirements and our team will respond within 1 business day.






    Heavy Duty Industrial Fans & Blowers Manufacturer | Custom Solutions - LONGWELL

    Engineering heavy-duty, energy-efficient, and customizable airflow solutions for global manufacturing and HVAC applications.

    Category A: OEM and Engineering Components (Heavy-Duty & Engineering)

    Category B: Commercial Ventilation Finished Products & Wholesale

    Industrial Ceiling Fans

    Industrial Ceiling Fans

    Industrial Misting Fans

    Industrial Misting Fans

    Wall Mounted Industrial Fan

    Wall Mounted Industrial Fan

    Industrial Drum Fan

    Industrial Drum Fan

    Industrial Floor Fans

    Industrial Floor Fans

    Industrial-Pedestal-Fan

    Industrial Pedestal Fan

    Tripod Stand Fan

    Tripod Stand Fan

    Dock Fan

    Industrial Centrifugal Fans

    Longwell Air Conditioner Fan Blade Size Chart

    ModelTypeSize(Inch)PowerVoltage(V)Rotate speed(r/min)Air Flow(m³/min)Noise[(dB(A)]Height(m)Diameter(m)MoterVelocityCapacity(L)Color
    LW-ECCF-7.3Industrial Ceiling Fan1.6KW220/38010800≤407.3
    LW-ECCF-6.2Industrial Ceiling Fan1.3KW220/3809800≤406.2
    LW-ECCF-5.2Industrial Ceiling Fan1.1KW220/3808600≤405.2
    LW-ECCF-4.2Industrial Ceiling Fan0.75KW220/3806600≤404.2
    LW-ECCF-3.2Industrial Ceiling Fan0.52KW220/3803600≤403.2
    LW-ECCF-2.6Industrial Ceiling Fan0.52KW220/3803600≤402.6
    LWIF-650(26")S(U)-01AMist Fan26260W220/1101451.75100% copper349blue
    LWIF-650(26")S(U)-01CMist Fan26260W220/1101451.75100% copper349blue
    LWIF-750(30")S(U)-01AMist Fan30350W220/1101451.75100% copper349blue
    LWIF-750(30")S(U)-01CMist Fan30350W220/1101451.75100% copper349blue
    LWIF-650(26")S(U)-02AMist Fan26260W220/1101451.75100% copper345black
    LWIF-650(26")S(U)-02BMist Fan26260W220/1101451.75100% copper345black
    LWIF-650(26")S(U)-02CMist Fan26260W220/1101451.75100% copper345black
    LWIF-750(30")S(U)-02AMist Fan30350W220/1101451.75100% copper345black
    LWIF-750(30")S(U)-02BMist Fan30350W220/1101451.75100% copper345black
    LWIF-750(30")S(U)-02CMist Fan30350W220/1101451.75100% copper345black
    LWIF-500(20")U(S)-01BMist Fan (hand pushed)20500W220/110
    LWIF-500(20")U(S)-01AMist Fan (hand pushed)20350W220/110
    LWIF-500(20")U(S)-02BMist Fan (hand pushed)20550W220/110
    LWIF-500(20")U(S)-01CMist Fan (Suspended)20550W220/110
    LWIF-650(26")S(U)-03AMist Fan26260220/1101451.75100% copper345black
    LWIF-650(26")S(U)-03BMist Fan26260220/1101451.75100% copper345black
    LWIF-750(30")S(U)-03AMist Fan30350220/1101551.75100% copper345black
    LWIF-750(30")S(U)-03BMist Fan30350220/1101551.75100% copper345black
    LWIF-650(26")S(U)-04AMist Fan26260220/110145100% copper310white
    LWIF-750(30")S(U)-04AMist Fan30350W220/110145100% copper310white
    LWIF-500(20")T(S)(U)-03AIndustrial Wall Fan20120W380/220/1101380170550.5
    LWIF-650(26")T(S)(U)-05AIndustrial Wall Fan26260380/220/1101380205630.65
    LWIF-750(30")T(S)(U)-05AIndustrial Wall Fan30350380/220/1101380290690.7
    LWIF-500(20")T(S)(U)-04A20120W380/220/1101380170550.5
    LWIF-650(26")T(S)(U)-06A26260W380/220/1101380205630.65
    LWIF-750(30")T(S)(U)-06A30350W380/220/1101380290690.75
    LWIF-500(20")T(S)(U)-04B20120W380/220/1101380170550.5
    LWIF-650(26")T(S)(U)-06B26260W380/220/1101380205630.65
    LWIF-750(30")T(S)(U)-06B30350W380/220/1101380290690.75
    LWF-250(10")S-01A1065220900-14000.25
    LWF-300(12")S-01A1270220900-14000.3
    LWF-350(14")S-01A1495220900-14000.35
    LWF-400(16")S-01A16125220900-14000.4
    LWF-450(18")S-01A18165220900-14000.45
    LWF-500(20")S-05A20195220900-14000.5
    LWIF-450(18")S-02AHome Commercial Fan180W2200.333333333333330.45
    LWIF-500U(S)-0120130110~120
    220~240
    138015058
    LWIF-600U(S)-0124215110~120
    220~240
    138019560
    LWIF-650U(S)-0126230110~120
    220~240
    138020561
    LWIF-750U(S)-0130260110~120
    220~240
    138029065
    LWIF-450U(S)-0118110110~120
    220~240
    138013055
    LWIF-500U(S)-0220130110~120
    220~240
    138015058
    LWIF-600U(S)-0224215110~120
    220~240
    138019560
    LWIF-650U(S)-0226230110~120
    220~240
    138020561
    LWIF-750U(S)-0230260110~120
    220~240
    138029065
    LWIF-850U(S)-0134290110~120
    220~240
    138032068
    LWIF-450U(S)-02Industrial Tripod Stand Fan18110110~120
    220~240
    138013055
    LWIF-500U(S)-03Industrial Tripod Stand Fan20130110~120
    220~240
    138015058
    LWIF-600U(S)-03Industrial Tripod Stand Fan24215110~120
    220~240
    138019560
    LWIF-650U(S)-03Industrial Tripod Stand Fan26230110~120
    220~240
    138020561
    LWIF-750U(S)-03Industrial Tripod Stand Fan30260110~120
    220~240
    138029065
    LWIF-850U(S)-02Industrial Tripod Stand Fan34290110~120
    220~240
    138032068
    LWF-650U(S)-04Industrial Mist Fan26190110~120
    220~240
    138020561
    LWF-750U(S)-04Industrial Mist Fan30220110~120
    220~240
    138029065
    LWIF-450U(S)-033 in 1 Industrial Fan1855W110~120
    220~240
    130012050
    LWIF-450U(S)-04Commercial Stand and Wall Fan18135W110~120
    220~240
    138012555
    LWIF-450U(S)-05Commercial Floor Fan18135~150110~120
    220~240
    138012555
    LWIF-450U(S)-06Commercial Floor Fan18135~150110~120
    220~240
    138012555
    LWIF-500U(S)-04Commercial Floor Fan20135~150110~120
    220~240
    138012557
    LWF-250U(S)-01Powerful Floor Fan1030110~120
    220~240
    13502342
    LWF-300U(S)-01Powerful Floor Fan1240110~120
    220~240
    13503645
    LWF-350U(S)-01Powerful Floor Fan1460110~120
    220~240
    13507050
    LWF-400U(S)-01Powerful Floor Fan1680110~120
    220~240
    13508852
    LWF-450U(S)-07Powerful Floor Fan18100110~120
    220~240
    13509555
    LWF-500U(S)-05Powerful Floor Fan20120110~120
    220~240
    135010058

    Catalogs & Brochures for Industrial Fans

    Heavy Duty Industrial Fan Performance & Wind Tunnel Test
    3D CAD Models | Fan Performance Curves | Installation Manuals

    Longwell: Your Premier Industrial Fans Supplier in China

    Industrial fans are robust air movement systems developed for commercial and industrial environments where large-scale ventilation, cooling, and process airflow are required. Beyond basic cooling, they form an essential part of ventilation networks, manufacturing operations, HVAC systems, and overall facility air management.

     

    Manufactured with heavy-gauge steel, aluminum alloys, or corrosion-resistant materials, and equipped with efficient motor systems, Longwell industrial fans are built for dependable operation. Typical operating temperature ranges extend from –20°C to +60°C, depending on configuration. Airflow capacities generally range from 2,000 to 50,000 m³/h, with models available for both low- and high-static-pressure applications to match different installation requirements.

     

    Common configurations include axial fans, centrifugal fans, floor fans, wall-mounted fans, and tripod stand fans. By supporting effective air circulation and maintaining stable indoor air conditions, industrial fans play a key role in improving production efficiency, enhancing workplace safety, and optimizing overall energy performance in industrial facilities.

    Contact Us Now






      Why Choose Longwell Industrial Fans

      ● Reliable Product Performance

      Longwell industrial fans are designed for stable airflow, low noise, and long service life. With optimized aerodynamic designs and strict quality testing, our products deliver reliable performance in HVAC, heating, and ventilation systems.

      ● Strong Manufacturing Capability

      Our modern manufacturing facility is equipped with advanced production and testing equipment, ensuring consistent quality and precision. Experienced engineers and strict quality control allow us to maintain reliable performance across every production batch.

      ● Flexible OEM & Custom Solutions

      Longwell offers flexible OEM and custom manufacturing services to meet diverse application needs. From design support to mass production, our team works closely with customers to deliver fan solutions tailored to their specific requirements.

      ● High Configuration

      Constructed with high-durability materials including high-strength aluminum alloy housing and corrosion-resistant stainless steel blades, Longwell industrial fans ensure long-term stable operation in high-temperature, high-humidity, and dusty environments. Our products feature IP55+ protection and optimized heat dissipation, effectively resisting oil and moisture damage while extending motor lifespan.

      Features of Air Conditioner Fan Blade

      Customizable

      Customizable

      Flexible OEM and custom fan solutions designed to match your equipment requirements.
      Energy-Efficient

      Energy-Efficient

      Optimized aerodynamic design helps reduce energy consumption while maintaining stable airflow.

      Predictive Maintenance

      Predictive Maintenance

      Durable components and reliable design support longer service intervals and reduced downtime.
      International Certification

      International Certification

      Products meet international standards to ensure quality, safety, and global compatibility.

      Specifications of Industrial Fans

      ● Voltage Ranges: 230V

      ● Frequency: 50/60 Hz

      ● Diameter: 30mm (impeller diameters)

      ● Motor Types: BLEC External Rotor Motor

      ● Speed Control: 0-10V Signal / PWM / RS485(Optional)

      ● Ambient Temp: -25°C~ +60°C

      ● Certificating: All necessary certifications suitable for USA & Europe, ETL, UIL, CE, ROHS, ISO19001, ISO 14001, BSCI

      ● Protection Level: IP44 ,IP54,IP55

      ● Electronic Protection: Current limiting protection, Over-temperature protection, Over-current protection, Locked-rotor protection, Soft start

      ● Working & Storage: Operating temperature: -25-60°C; Operating humidity: 0~85 % RH

      ● Storing temperature: -25 ~ 70°C; Storing humidity: 0~95 % RH

      ● Applicable altitude range: <1000m

      ● Balancing: According to JB/T 9101-1999 requirements G6.3

      How to Choose the Best Industrial Fan for Your Warehouse

      Excessive temperature in large warehouses or factories can lead to a series of consequences, including low employee productivity, reduced efficiency, and increased energy costs. Therefore, efficient ventilation is crucial, making industrial fans indispensable, provided you choose the most suitable fan for the space.

      When selecting industrial fans for your large warehouse, consider factors such as the size of the ventilation area, durability, energy efficiency, noise level, maintenance requirements, and environmental conditions. Ensure you choose an industrial fan that best suits your warehouse size and environment, achieving maximum efficiency.

      If your warehouse has a large space or high ceilings, HVLS fans are the best choice. They draw in large volumes of air at low speeds, providing ample airflow throughout the warehouse at a relatively low energy cost.

      When your warehouse ventilation needs are not high, axial fans can quickly deliver air over long distances. Ideally, they should be installed in conjunction with a heating, ventilation, and air conditioning (HVAC) system for optimal ventilation.

      Centrifugal fans are best suited for high-pressure applications and duct systems. It can provide directional airflow to specific areas within the warehouse, and its cleverly designed casing makes it unaffected by dust, debris, and other impurities in the air.

      What Our Customers Say after Used

      Applications of Industrial Fans

      Laboratory

      Laboratory

      Both indoor and outdoor units of household air conditioners require blades. The indoor unit typically uses through-flow or centrifugal blades, while the outdoor unit employs axial-flow blades. These components function through distinct structural designs and operational principles to guide airflow in specific directions, ensuring the air conditioner operates efficiently.
      Factories

      Factories

      Compared with household air conditioners, cars require more space for the blades, so compact centrifugal or axial flow blades are popular in car air conditioners. These plastic blades have high rigidity and can adapt to the high temperature and vibration environment inside the car.
      Sports Fields

      Sports Fields

      Cascading air blades are the ideal choice for air curtains. They are usually installed above the door to create a uniform, continuous curtain of air that effectively blocks outdoor microbes such as dust, smoke, odors and insects, and prevents indoor heating and cooling from escaping, saving electricity.
      Stations

      Stations

      Water-cooled air conditioners are often located in humid environments, so corrosion-resistant plastic blades are the perfect choice. They effectively resist corrosion from moisture and chemicals, preventing rust like metal blades do, thus ensuring long-term stable operation of the equipment.
      Schools

      Schools

      The plastic fan blades in the heater need to withstand high outlet temperature. Engineering plastics, such as PPS, can maintain stable shape and function at a certain high temperature, and its axial flow design can effectively blow hot air uniformly.
      Farms

      Farms

      The ventilation system of elevator cabins has a very limited space and high noise control requirements. Small axial flow or centrifugal plastic blades can well balance air volume, volume and noise, ensuring fresh air in the cabin and keeping the operating sound at a low level.

      What Our Customers Say after Used

      Frequent Questions You May Have about Air Conditioner Fan Blade

      1. What are the different types of industrial fans and their applications?

      The most common types of industrial fans include centrifugal fans, axial fans, and mixed flow fans. Centrifugal fans are typically used in systems that require higher pressure, such as HVAC equipment and dust extraction.

      Axial fans are designed for moving large volumes of air in ventilation or cooling applications. Mixed flow fans combine the advantages of both designs, offering balanced airflow and pressure performance.

      LONGWELL provides a wide range of industrial fan solutions, and our engineering team can help recommend the right model based on your airflow and installation requirements.

      The operating cost of an industrial fan largely depends on motor efficiency and system design. Modern industrial fans equipped with EC motors (electronically commutated motors) consume significantly less electricity than traditional AC motor systems.

      LONGWELL integrates energy-efficient EC motor technology in many fan models, helping customers reduce power consumption while maintaining high airflow performance. Although high-efficiency fans may have a slightly higher upfront cost, the long-term energy savings typically provide a strong return on investment.

      Yes. LONGWELL offers OEM and ODM manufacturing services for industrial fans used in demanding environments.

      Our engineering team can design custom fan solutions with corrosion-resistant materials such as stainless steel, specialized alloys, or protective coatings. We also provide options for high-temperature applications, dust-laden environments, and other industrial conditions where standard fans may not perform reliably.

      Like most mechanical equipment that moves large volumes of air, industrial fans generate some level of noise during operation. However, well-designed fans can significantly reduce sound levels through optimized impeller design and precise dynamic balancing.

      LONGWELL industrial fans are engineered to maintain stable airflow while keeping noise within widely accepted industrial safety standards, making them suitable for continuous operation in commercial and industrial environments.

      Need a Specific Blower or Fan? Please Contact Today!

      Send Your Inquiry Today!