Looking for an alternative for Ziehl-Abegg FN063-VDK.4F.V7? The LONGWELL LWAE3G630 has the same impeller diameter. Catalogue ratings, measured curves and dimensioned drawings for every model are on the LONGWELL Fan Selector; final selection is made at your duty point. Typical applications: Premium heat pump, data center free cooling, dry cooler, large BESS.
| Specification | Ziehl-Abegg FN063 | LONGWELL LWAE3G630 |
|---|---|---|
| Fan type | EC axial fan | EC axial fan |
| Impeller diameter | Ø630 mm | Ø630 mm 11 models |
| Airflow range | 5,500–17,500 m³/h | up to 14,935 m³/h |
| Static pressure (max) | 420 Pa | up to 258 Pa |
| Motor power (max) | 3,200 W | up to 887 W |
| Noise floor (Lw) | 76 dB(A) | from 69 dB(A) (nameplate, per model) |
| Voltage | 380–480 V 3Φ | 220–230 V 1Φ · 380–400 V 3Φ |
| Control input | 0–10 V / PWM / Modbus / EC-Control | 0–10 V / PWM / Modbus RTU (RS485) |
| IP rating | IP54 / IP55 | IP54 (per model) |
| Certifications | CE · UL · VDE · EAC | CE · RoHS |
| Sample lead time | Per manufacturer quotation | 1–3 days |
| Series lead time (≤500 units) | Per manufacturer quotation | 15–30 days |
| Pricing | Per manufacturer quotation | Quoted per project |
Mounting dimensions, inlet ring diameter, motor shaft height and terminal-box position of the LONGWELL LWAE3G630 are given on its dimensioned drawing. Compare them with the installed fan before ordering.
The LONGWELL LWAE3G630 accepts a 0–10 V analog speed reference, PWM and Modbus RTU (RS485) control signals (per model; see the model datasheet). LONGWELL supplies its Modbus RTU register map with the fan so the BMS points can be re-mapped; the register addresses are not identical to the Ziehl-Abegg map.For other bus protocols, ask LONGWELL engineering for the integration options.
The measured P-Q curve of every LONGWELL model is on its model page; we check your duty point against it before quoting.
The LWAE3G630 is typically specified for Premium heat pump, data center free cooling, dry cooler, large BESS. Common application categories include:
Particularly suited for premium heat pump and data center free cooling.
Send a quick request — model + quantity + delivery address. Sample unit ships in 1–3 days for field validation. Series production at 15–30 day lead time after PO.
Request Sample View Full Cross-Reference TableLeave your requirements and our team will respond within 1 business day.
Fill in the form — your download starts immediately.
* Your information is only used for catalog delivery and professional support.