Looking for an alternative for Ziehl-Abegg RH31C-VDK? The LONGWELL LWBE3G-310-EC is the dimensionally interchangeable equivalent — same mounting, same control protocol, AMCA 210/211 third-party-tested performance — at 40–55% lower landed cost with 15-day delivery vs 12–18 weeks ex-works Ziehl-Abegg. Widely deployed across Commercial AHU, cold chain condensing unit, hybrid heat pump.
| Specification | Ziehl-Abegg RH31C | LONGWELL LWBE3G-310-EC |
|---|---|---|
| Fan type | EC backward-curved centrifugal plug fan | EC backward-curved centrifugal plug fan |
| Impeller diameter | Ø315 mm | Ø315 mm Drop-in |
| Airflow range | 650–3,200 m³/h | 650–3,200 m³/h |
| Static pressure (max) | 1000 Pa | 1000 Pa |
| Motor power (max) | 650 W | 650 W |
| Wire-to-air η peak (AMCA 210) | 89% | 86% |
| Noise floor (Lw) | 65 dB(A) | 68 dB(A) |
| Voltage | 200–240 V 1Φ | 200–240 V 1Φ |
| Control input | 0–10 V / PWM / Modbus / EC-Control | 0–10 V / PWM / Modbus RTU / Modbus TCP Compatible |
| IP rating | IP54 / IP55 | IP54 std · IP55 / IP67 option |
| Certifications | CE · UL · VDE · EAC | CE · UL · cUL · TÜV · ATEX · VDE · EAC · RoHS · REACH |
| Sample lead time | 4–10 weeks | 1–3 days |
| Series lead time (≤500 units) | 12–18 weeks | 15–30 days |
| Landed cost index (LONGWELL = 100) | 175–200 | 100 (baseline) |
The LONGWELL LWBE3G-310-EC matches the Ziehl-Abegg RH31C mounting pattern (M-mount, ISO 9001 plenum-fan footprint) within ±0.5 mm tolerance. Inlet ring diameter, motor shaft height, and electrical termination box position are identical. Drop-in retrofit requires no AHU rework, no plate modification, and no plenum hole resizing.
The LWBE3G-310-EC accepts the same 0–10 V analog speed reference, PWM (1 kHz), and Modbus RTU (RS485) control signals as Ziehl-Abegg RH31C. Default Modbus register map is compatible with the Ziehl-Abegg ecosystem; LONGWELL provides a free Modbus map cross-reference for BMS integration. Ziehl-Abegg-specific proprietary protocols (EC-Control bus / ZA-control) are bridged via a free MODBUS gateway available from LONGWELL Engineering — no BMS reprogramming required.
The PQ curve of LONGWELL LWBE3G-310-EC sits within 2–3% of the Ziehl-Abegg RH31C curve across the full operating envelope (verified by third-party AMCA 210/211 testing at TÜV and Intertek labs). Wire-to-air efficiency at BEP is 86% vs 89% for Ziehl-Abegg (3 pp delta at peak). In typical part-load HVAC duty, the gap narrows to within 1 pp.
The LWBE3G-310-EC is widely deployed across Commercial AHU, cold chain condensing unit, hybrid heat pump. Common application categories include:
Particularly suited for cold chain condensing units and hybrid heat pump split sections.
Send a quick request — model + quantity + delivery address. Sample unit ships in 1–3 days for field validation. Series production at 15-day lead time after PO.